    Publication Date: 2011-08-24
    Description: A model rotor acoustic test was performed to examine the benefit of higher control (HHC) of blade pitch to reduce blade-vortex interaction (BVI) impulse noise. A 40-percent dynamically scaled, four-bladed model of a BO-105 main rotor was tested in the German-Dutch Wind Tunnel (DNW). Acoustic measurements were made in a large plane underneath the rotor employing a traversing in-flow microphone array in the anechoic environment of the open test section. Noise characteristics and noise directivity patterns as well as vibratory loads were measured and used to demonstrate the changes when different HHC schedules (different modes, amplitudes, phases) were applied. Dramatic changes of the acoustic signatures and the noise radiation directivity with HHC phase variations are found. Compared to the baseline conditions (without HHD), significant mid-frequency noise reductions of as much as 6 dB are obtained for low speed descent conditions where BVI is most intensive. For other rotor operating conditions with less intense BVI there is less or no benefit from the use of HHC. Low frequency loading noise and vibratory loads, especially at optimum noise reduction control settings, are found to increase.
    Keywords: AIRCRAFT DESIGN, TESTING AND PERFORMANCE
    Type: American Helicopter Society, Journal (ISSN 0002-8711); 39; 4; p. 3-13
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: The noise of an aeroelastically scaled helicopter rotor has been studied in the German-Dutch wind tunnel in order to assess the utility of higher-harmonic control (HHC) in reducing blade-vortex interaction (BVI) noise. Acoustic data are presented for 3/rev, 4/rev, and 5/rev HHC, as applied to a typical landing approach rotor operating condition; noise reduction of up to 6 dB were found for advancing-blade BVI noise radiating upstream of the rotor, as well as for retreating blade BVI noise radiating below and downstream of the rotor.
    Keywords: ACOUSTICS
    Type: In: AHS and Royal Aeronautical Society, Technical Specialists' Meeting on Rotorcraft Acoustics(Fluid Dynamics, Philadelphia, PA, Oct. 15-17, 1991, Proceedings (A93-29401 10-71); 15 p.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-06-28
    Description: During the Higher Harmonic Control Aeroacoustic Rotor Test, extensive measurements of the rotor aerodynamics, the far-field acoustics, the wake geometry, and the blade motion for powered, descent, flight conditions were made. These measurements have been used to validate and improve the prediction of blade-vortex interaction (BVI) noise. The improvements made to the BVI modeling after the evaluation of the test data are discussed. The effects of these improvements on the acoustic-pressure predictions are shown. These improvements include restructuring the wake, modifying the core size, incorporating the measured blade motion into the calculations, and attempting to improve the dynamic blade response. A comparison of four different implementations of the Ffowcs Williams and Hawkings equation is presented. A common set of aerodynamic input has been used for this comparison.
    Keywords: AERODYNAMICS
    Type: NASA-TM-110825 , NAS 1.15:110825 , AD-A294477
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2018-12-01
    Description: Results are presented of a model rotor acoustics test performed to examine the benefit of higher harmonic control (HHC) of blade pitch to reduce blade-vortex interaction (BVI) impulsive noise. A dynamically scaled, four-bladed, rigid rotor model, a 40-percent replica of the B0-105 main rotor, was tested in the German Dutch Wind Tunnel. Noise characteristics and noise directivity patterns as well as vibratory loads were measured and used to demonstrate the changes when different HHC schedules were applied. Dramatic changes of the acoustic signatures and the noise radiation directivity with the HHC phase variations are found. Compared to the baseline conditions (without HHC), significant mid-frequency noise reductions of locally 6 dB are obtained for low-speed descent conditions where GVI is most intense. For other rotor operating conditions with less intense BVI there is less or no benefit from the use of HHC. LF noise and vibratory loads, especially at optimum noise reduction control settings, are found to increase.
    Keywords: ACOUSTICS
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...