ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Sammlung
Erscheinungszeitraum
  • 1
    Publikationsdatum: 2019-10-14
    Beschreibung: The present work conducts an evaluation of the feasibility and the overall performance and consequent optimization of a direct expansion solar assisted heat pump (DXSAHP) employed for domestic water heating. For the study conducted R134a, R404A, R407C and R410A working fluids were evaluated as well as the use of four, six and eight flat-plate solar collectors and a worktime ranging from 1 to 6 h. The case study is based in Mexico City with a 300 L container and a hot water outlet temperature of 51 °C. The paper introduces a new evaluation criterion based on the thermal capacity and all the evaluations conducted throughout this research revolve around this performance metric. The results show that, the system would require at least 4 h of operation to achieve the outlet temperature. Additionally, it was found that the R410A refrigerant has the best heat transfer properties; with an average condensation heat rate of 6.31 kW, followed by the R407C with 5.72 kW, the R404A with 5.42 kW and the R134a with 5.18 kW. Diversely, the R134a refrigerant requires 0.402 kW of compression work, 62% less than the R410A, which requires 1.06 kW. Consequently, R134a delivers the highest COP, which ranges from 7 to 14, followed by the R407C and R404A refrigerants, which present a similar behaviour between them, with COP ranging from 5 to 9 and 4 to 8, respectively, and finally the R410A, achieving the lowest COP, ranging from 3.5 to 6.5. Moreover, it was found that the R134a presents a higher dispersion regarding the energy exchange rate, which reveals that it is the fluid most susceptible to external factors, such as the weather. Contrarily, the remaining refrigerants present a more consistent performance. Finally, the optimization revealed that the R407C refrigerant is the most suitable given that it requires 20% less compression work than the R404A. This provides the heat pump system with a steadier behaviour, a COP ranging from 7 to 8, 30% higher than R410A, a worktime decrease of 1.5 h and heat transfer area of 5.5 flat-plate solar collectors, equivalent to a 31% reduction, both compared to R134a.
    Digitale ISSN: 1996-1073
    Thema: Energietechnik
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Publikationsdatum: 2018-04-30
    Beschreibung: Background The most traditional scheme for migration among baleen whales comprises yearly migrations between productive waters at high latitude summer feeding grounds and warmer waters at lower latitudes where whales calve and mate, but rarely feed. Evidence indicates, however, that large departures from this scheme exist among populations and individuals. Furthermore, for some populations there is virtually no information on migratory pathways and destinations. Such is the case of Chilean blue whales throughout the Eastern South Pacific; hence, the goal of this study was to assess its migratory behavior. Methods Dedicated marine surveys and satellite tagging efforts were undertaken during the austral summer and early autumn on blue whale feeding grounds off Chilean Northern Patagonia (CNP) during 2013, 2015 and 2016. Positional data derived from satellite tags regarding movement patterns and behavior were analyzed using Bayesian switching first-difference correlated random walk models. Results We instrumented 10 CNP blue whales with satellite transmitters and documented individual variation in departure time, northbound migratory routes and potential wintering grounds. The onset of migration occurred from mid/late austral autumn to well into the austral winter. Blue whales moved in various directions, but ultimately converged toward a general NW movement direction along a wide corridor exceeding 2,000 km. Area-Restricted Search behavior was exhibited within fjords and channels of CNP and also South of Galapagos Archipelago (GA) and northern Peru, but never during migration. Interestingly, dive profiles for one whale that reached GA showed a sharp and consistent increase in depth north of 5°S and extreme deep dives of up to 330 m. Discussion Information derived from satellite tagged blue whales in this study is the first of its kind off the Eastern Southern Pacific. Our results provide valuable information on their migratory timing, routes and behavior on their northbound migration, particularly regarding the varied migratory plasticity for this particular population. Our results also highlight the first record of two complete migratory paths between CNP and GA and strengthen the hypothesis that GA waters correspond to a potential wintering destination for CNP blue whales. We further hypothesize that this area might be selected because of its biological productivity, which could provide feeding opportunities during the breeding season. Our results suggest that special efforts should be put forward to identify blue whale critical areas and understand key behavioral aspects in order to provide the basis for their conservation on a regional context (i.e., reducing potential ship strike and promote Marine Protected Area (MPA) implementation in Chile, Ecuador and Peru). Indeed, we suggest joint blue whale conservation efforts at the regional level in order to identify and determine potential threats and impacts and, most importantly, implement prospective management actions.
    Digitale ISSN: 2167-8359
    Thema: Biologie , Medizin
    Publiziert von PeerJ
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...