ISSN:
0021-8995
Schlagwort(e):
Chemistry
;
Polymer and Materials Science
Quelle:
Wiley InterScience Backfile Collection 1832-2000
Thema:
Chemie und Pharmazie
,
Maschinenbau
,
Physik
Notizen:
Gel permeation chromatography produces a type of differential molecular weight distribution directly and rapidly. Conversion of these data to conventional molecular weight distributions and plots of distributions is time-consuming. A computer program is described to perform these operations readily. Input data from the automated chromatograph, elution volume, and recorder deflection are converted to unit sensitivity and base line corrections applied. The curve is then numerically integrated and a calibration curve used to convert elution volumes into molecular weights. Various calibration curves can readily be introduced into the program. The output, in addition to tabulation of cumulative and differential molecular weight distributions, contains values of M̄n, M̄v, M̄w, M̄z, and M̄z+1. Importantly, a reduced absolute area, i. e., area computed for unit sensitivity on a unit concentration basis, is tabulated. An additional time-saving eature is the printing out of differential and cumulative molecular weight distribution curves and of a differential histogram.
Zusätzliches Material:
3 Ill.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1002/app.1966.070100608