ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 1988-03-01
    Print ISSN: 0948-7921
    Electronic ISSN: 1432-0487
    Topics: Electrical Engineering, Measurement and Control Technology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 1986-03-01
    Print ISSN: 0948-7921
    Electronic ISSN: 1432-0487
    Topics: Electrical Engineering, Measurement and Control Technology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 1981-01-01
    Print ISSN: 0948-7921
    Electronic ISSN: 1432-0487
    Topics: Electrical Engineering, Measurement and Control Technology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 64 (1981), S. 109-114 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Übersicht Während des Hochlaufs eines Asynchronmotors fließen hohe Ströme. Diese können durch eine Stern-Dreieck-Umschaltung der Wicklungen verringert werden. Kurz nach dem Umschaltaugenblick entstehen jedoch hohe Strom- und Drehmomentspitzen. Diese Spitzen sin dabhängig von der Art der Stern-Dreieck-Umschaltkonfiguration und vom Schaltaugenblick während des Hochlaufs. Der Aufsatz beschreibt eingehend diese Abhängigkeiten und das dabei entstehende Strom- und Drehmomentverhalten. Es werden optimale Umschaltzeitpunkte diskutiert. Die Berechnungen beruhen auf der Darstellung des Asynchronmotor-Verhaltens durch Raumzeiger und wurden mit einem digitalen Simulationsprogramm durchgeführt. Besonderer Wert wurde auf die physikalische Interpretation der Ergebnisse gelegt.
    Notes: Contents During the starting of an induction motor currents are very high. Through the switching of the windings from a star- to a delta-configuration the currents are diminished. But there are high current and torque transients shortly after the switching moment. These transients are dependent on the type of the star-delta-connections and on the switching moment during the rup-up. This paper presents a through investigation of these dependencies and the resulting current and torque performance. Optimal switching moments will be discussed. The calculations are based on the presentation of the behaviour of the induction motor by space-phasors and is done by digital simulation on a computer. Great importance is put on a physical interpretation of the results.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 71 (1988), S. 107-113 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Contents A voltage-inverter-fed synchronous motor contains in its inverter voltage valves, i.e. thyristors with antiparallel diodes. They allow, due to their commutating abilities, higher speeds than motors with an inverter containing current valves, i.e. just thyristors. A disadvantage is a starting procedure which is complicated first by the diodes and second by the condenser in thedc link. But there are control strategies which compensate these disadvantages. This paper describes necessary control procedures for a safe run-up of the motor. Digital simulation and results of an experimental drive system verify the calculated values.
    Notes: Übersicht Ein Spannungsrichtermotor enthält in seiner Umrichterschaltung Spannungsventile — Thyristoren mit antiparallelen Dioden — die aufgrund ihrer Kommutierungseigenschaften höhere Drehzahlen als bei Stromrichtermotoren mit ihren Stromventilen, die nur aus Thyristoren bestehen, erlauben. Ein Nachteil besteht in einem durch die Dioden erschwerten Anlaufverfahren, das darüber hinaus durch den Zwischenkreiskondensator behindert wird. Es gibt jedoch Steuerstrategien, die diesen Nachteil aufheben. Der Aufsatz beschreibt die notwendigen Steuermaßnahmen, um einen sicheren Anlauf zu gewährleisten. Simulationsberechnungen und Ergebnisse aus einem experimentellen Antriebssystem bestätigen die berechneten Werte.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 69 (1986), S. 143-148 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Description / Table of Contents: Übersicht Ein Umrichter mit Thyristoren und antiparallelen Dioden (Spannungsventilen), der einer Synchronmaschine vorgeschaltet ist, eröffnet die Möglichkeit, die Synchronmaschine mit höheren Drehzahlen als beim Stromrichtermotor, der nur Thyristoren (Stromventile) enthält, zu betreiben. Der Nachteil des nicht so einfachen Anlaufs der Maschine kann durch eine geeignete Steuerstrategie, die die zusätzlich induzierten Diodenfreilaufströme und Maschinenfreilaufströme berücksichtigt, kompensiert werden. Diese Ströme hängen von Maschinenparametern und insbesondere vom Steuerwinkel ab, wie im einzelnen erläutert wird. Eine digitale Simulation und Resultate aus einem experimentellen Antriebssystem bestätigen die theoretisch berechneten Kurven.
    Notes: Contents An inverter with thyristors and antiparallel diodes (voltage valves) connected to a synchronous machine offers the possibility of operating the motor at higher speeds than the so-called current-converter motor — a synchronous motor fed by an inverter with thyristors (current valves) — is able to do. The disadvantage of a more complex run-up performance can be overcome by a control strategy which takes care of the additionally induced free-wheeling diode and machine currents. These currents depend on machine parameters and especially on the control angle as is explained. Digital simulation and results from an experimental drive system verify the calculated characteristics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...