ISSN:
1662-9779
Source:
Scientific.Net: Materials Science & Technology / Trans Tech Publications Archiv 1984-2008
Topics:
Physics
Notes:
As for thin walled cylindrical liquid storage tanks in nuclear power plants, the currentelastic design guideline against seismic loading might result in too conservative component design.Therefore, it is thought possible to make the design procedure more reasonable by taking dynamicresponse reduction into account. Experiments using scaled models as well as numerical analyseswere carried out, and seismic behavior of thin walled cylindrical liquid storage tanks was simulatedto investigate energy absorption capacity and seismic resistance of those tanks. Based on the testand analysis results, assessment procedure for buckling considering post-buckling behavior hasbeen proposed
Type of Medium:
Electronic Resource
URL:
http://www.tib-hannover.de/fulltexts/2011/0528/02/23/transtech_doi~10.4028%252Fwww.scientific.net%252FSSP.120.199.pdf
Permalink