ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-04-25
    Description: Design and performance of extreme ultraviolet optical telescope for space astronomy
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NIFICANT ACCOMPLISHMENTS IN SCI. AND TECHNOL. AT GODDARD SPACE FLIGHT CENTER 1970; P 295-298
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Description: The focal shift of the Wolter type II telescope, a glancing incidence analog of the normal incidence Cassegrain telescope, due to the despacing of the secondary with respect to the primary, is analyzed. The location of the rms best focus on the optical axis can be derived from a resulting expression. The results are verified by ray tracing of an actual Wolter type II telescope.
    Keywords: OPTICS
    Type: Applied Optics (ISSN 0003-6935); 25; 1744
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-12
    Description: Optical design of Wolter type 1 glancing incidence X ray telescope for 6-100 A wavelength region, describing results of laboratory and rocket flight tests of prototype
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ; ADEMIE DES SCIENCES
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-16
    Description: Glancing incidence extreme UV telescopes optical design in solar physics applications, employing surfaces of revolution
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ; ADEMIE DES SCIENCES
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-16
    Description: A technique is described for use in the fabrication of glancing incidence telescopes which operate at large grazing angles (i.e., 8 to 15 degrees). Precision conic section plunge laps are used in a controlled grinding procedure to initially generate imaging surfaces which have a minimum of subsurface damage. A numerically controlled Moore Number 3 Measuring Machine is used throughout the fabrication procedure. Surface geometry accuracies on the order of one-tenth micron have been achieved.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Engineering; 13; Mar
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2016-06-07
    Description: Design optimization is reported for glancing telescopes of increased collecting areas. Considered are nested geometries for X-ray and extreme ultraviolet telescopes, each of which generates only one singular principal surface. In the case of the X-ray telescope, the field curvature of the outer telescope serves as a standard and the focus of each of the inner telescopes is made coplanar by a slight descrease in the collecting area of each of the inner telescopes. In the case of the EUV telescope, a slight change in the maximum slope angle of the inner telescope makes the field curvatures coincide. Five concentric X-ray telescopes form a collecting area of approximately 900 sq cm, and a nested EUV telescope consisting of two concentric telescopes produces a collecting area of about 45 sq cm.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Significant Accomplishments in Technol., GSFC, 1970; p 103-106
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-05-21
    Description: Resistive cell studies, coarse-grain-composite strength & conductivity, fine-grain-composite preparation, and design of small liquid metal cell
    Keywords: ELECTRONIC EQUIPMENT
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-13
    Description: A means is presented whereby the effect of various changes in the most important parameters of a three meter aperature space astronomy telescope can be evaluated to determine design trends and to optimize the optical design configuration. Methods are defined for evaluating the theoretical optical performance of axisymmetric, centrally obscured telescopes based upon the intended astronomy research usage. A series of design parameter variations is presented to determine the optimum telescope configuration. The design optimum requires very fast primary mirrors, so the study also examines the current state of the art in fabricating large, fast primary mirrors. The conclusion is that a 3-meter primary mirror having a focal ratio as low as f/2 is feasible using currently established techniques.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-CR-122399 , ER-10713
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗