ISSN:
0332-1649
Source:
Emerald Fulltext Archive Database 1994-2005
Topics:
Electrical Engineering, Measurement and Control Technology
,
Mathematics
Notes:
The calculation of magnetic shielding with ferromagnetic material by an effective reluctivity method and a time step method based on the finite element calculation is investigated. The calculation results of both methods are compared with measurement results and with each other in order to check their reliability and accuracy. It turns out that both methods give similar results for the field inside the shielding material, whereas in the surrounding air the effective reluctivity method gives more accurate results than the present time step method.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1108/03321649910274973