Abstract For the calculation of heat transfer between reactor tank and double tank wall as well as for the calculation of temperature distribution in the SNR fuel element, in case of an assumed necessity of emergency cooling of a fuel element with regard to a clamping in the fuel handling machine, it is necessary to know about the emissivity of the used austenitic steels. Measuring method, test setup, geometry and surface-conditions of the samples, protective gas impurity and method of test are described. — The emissivity of the austenitic steels 1.4948 (X 6 CrNi 1811) and 1.4961 (X 8 CrNiNb 1613) for different surface treatments is given within the temperature range from 200 °C to 700 °C.
Notes:
Zusammenfassung Zur Berechnung des Wärmeübergangs zwischen Reaktortank und Doppeltankw and sowie zur Berechnung der Temperaturverteilung im SNR-Brennelement für den angenommenen Störfall einer Notkühlung des Brennelements bei einem Klemmen in der Wechselmaschine, ist die Kenntnis des Emissionsvermögens der verwendeten austenitischen Stähle erforderlich. — Meßmethode, Versuchsaufbau, Art und Beschaffenheit der Proben, Schutzgasreinheit und Versuchsdurchführung werden beschrieben. — Das Emissionsvermögen der austenitischen Stähle 1.4948 (X 6 CrNI 1811) und 1.4961 (X 8 CrNiNb 1613) für verschiedene Oberflächenbehandlungen wird im Temperaturbereich von 200 °C bis 700 °C angegeben.