ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 2018-06-13
    Description: Sensors, Vol. 18, Pages 1915: Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode Sensors doi: 10.3390/s18061915 Authors: Józef Wiora Alicja Wiora An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also available. In order to show the advantages and disadvantages of the ways of uncertainty evaluation, i.e., the typical method, the MC method implemented in a program and in a spreadsheet, and commercial programs, a case of pH measurement after two-point calibration is considered in this article. The ways differ in the required mathematical transformations, degrees of software usage, the time spent for the uncertainty calculations, and cost of software. Since analysts may have different mathematical and coding skills and practice, it is impossible to point out the best way of uncertainty assessment—all of them are just as good and give comparable assessments.
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2018
    Description: Glass pH electrodes are still successfully applied in the chemical and environmental industry. During their long-term use, periodic calibration is required to maintain the required accuracy of measurements because the parameters of the electrodes change over time. This work presents an aging of 11 pH electrodes within approximately 600 days in tap water. During this period, potentials of all electrodes in five buffer solutions were measured 44 times. This allowed determining the aging models of the electrodes. Models in other mediums might be different. Changes in slope, standard potential, hysteresis, and linearity of the characteristics were the objects of observations. A method for predicting electrode parameters is proposed. Furthermore, the procedure for estimating the uncertainty of pH measurements considering the aging of the electrodes is described. As a result of this work, a model of the aging process of pH electrodes in tap water can be constructed and subsequently, the measurement accuracy in the periods between calibrations can be improved.
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Published by MDPI
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...