Publication Date:
2019-07-13
Description:
Active flow control technology is increasingly used in aerospace applications to control flow separation and to improve aerodynamic performance. In this paper, PowerFLOW is used to simulate the flow through a sweeping jet actuator at two different pressure ratios. The lower pressure ratio leads to a high subsonic flow, whereas the high pressure ratio produces a choked flow condition. Comparison of numerical results with experimental data is shown, which includes qualitatively good agreement of pressure histories and spectra. PIV measurements are also available but the simulation overestimates mean and fluctuation quantities outside the actuator. If supply pressure is matched at one point inside the mixing chamber a good qualitative agreement is achieved at all other monitor points.
Keywords:
Fluid Mechanics and Thermodynamics
Type:
NF1676L-21725
,
2016 AIAA SciTech Forum and Exposition; Jan 04, 2016 - Jan 08, 2016; San Diego, CA; United States
Format:
application/pdf
Permalink