Publication Date:
2019-06-27
Description:
Description of a two-foil system of iridium and tantalum which can measure thermal and intermediate energy neutrons at flux densities of 1 neutron/sq cm-sec over a ten-day lunar mission (1,000,000 neutrons/sq cm). The foils are chemically inert and nontoxic, weigh less than 1 g each, and require only routine gamma pulse height analysis for activation measurement. Detection of fluences below 1,000,000 neutrons/sq cm are achieved for counts of foil activity made as late as two months following neutron exposure. Tantalum foils flown in Apollo 11 indicated a mean dose equivalent to the astronauts of less than 16 mrem from thermal plus intermediate energy neutrons, while nuclear emulsion track analysis indicated approximately 17 mrem from neutrons of energy greater than 0.6 MeV. Iridium foils flown on Apollo 12 indicated dose equivalents of 1.8 to 2.8 mrem from thermal neutrons, excluding tissue thermalized SNAP-27 neutrons.
Keywords:
INSTRUMENTATION AND PHOTOGRAPHY
Type:
Health Physics; 22; May 1972