Description:
A two stage oil free screw compressor package was recently delivered to a major blue chip oil and gas giant for use on one of their oil platforms located in the North Atlantic. During initial design it became clear that the amount of instrumentation required on the package would be substantial. As a result of this an elegant solution was required that would move non-critical inputs and outs (IO) from the control panel to the package itself. This paper first describes the problems caused by the substantial amount of instrumentation required on the package. This description includes how the instrumentation is classed as critical and non-critical and what signals must still be sent over a hard wire and why. As the final location of the package is in an extremely hazardous environment, a highly corrosive marine environment, and the compressor itself is compressing highly combustible hydrocarbon gas, the protection methods employed by the instruments to prevent explosion is then...
Print ISSN:
1757-8981
Electronic ISSN:
1757-899X
Topics:
Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics