ISSN:
1572-8838
Source:
Springer Online Journal Archives 1860-2000
Topics:
Chemistry and Pharmacology
,
Electrical Engineering, Measurement and Control Technology
Notes:
Abstract Hydrodynamic and mass transfer parameters (pressure drop, gas and liquid hold-up, liquid-solid mass transfer coefficients) have been measured for porous electrodes with upward or downward co-current gas-liquid flow by means of several electrochemical techniques. The influence of the most important parameters (packing diameter, gas and liquid flow rates) and of the hydrodynamic flow regimes, has been studied. It is found that in the trickle flow regime the limiting current densities depend only on the liquid flow rates (with no measurable influence of the gas). In the upward flow configuration, the strong turbulence generated by the ascending gas bubbles leads to a sharp increase of current densities with the gas flow rate. A comparison between both configurations is presented.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF01006543
Permalink