ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-1634
    Keywords: two-phase flow ; ganglion dynamics ; immiscible displacement ; relative permeability ; enhanced oil recovery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Technology
    Notes: Abstract A comparative experimental study of ‘steady-state’ two-phase flow in two types of model porous media is made to determine the effects of nonplanarity on the flow mechanisms and the mesoscopic flow behavior. The two model porous media have virtually the same pore geometry, but one has a planar network skeleton, whereas the other has a nonplanar (two-layer) skeleton. The latter is a new type of model porous medium that permits detailed visual observation and quantitative measurements without sacrificing the 3D character of the pore network topology. The capillary number and the flowrate ratio are changed systematically, whereas the viscosity ratio and the wettability (contact angle) are kept constant. Conventional relative permeabilities are determined and correlated with the porescale flow phenomena. In the range of parameter values investigated, the flow mechanism observed was ganglion dynamics (intrinsically unsteady, but giving a time-averaged steady-state). The nonplanarity is shown to have small qualitative but significant quantitative effects. In the nonplanar porous medium, the ganglion size distribution is wider, the mean ganglion size larger, and the stranded ganglia are fewer than those in the planar one, under the same flow conditions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-1634
    Keywords: two-phase flow ; relative permeabilities ; ganglion dynamics ; viscous coupling ; coupling indices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Technology
    Notes: Abstract A parametric experimental investigation of the coupling effects during steady-state two-phase flow in porous media was carried out using a large model pore network of the chamber-and-throat type, etched in glass. The wetting phase saturation,S 1, the capillary number,Ca, and the viscosity ratio,k, were changed systematically, whereas the wettability (contact angleθ e ), the coalescence factorCo, and the geometrical and topological parameters were kept constant. The fluid flow rate and the pressure drop were measured independently for each fluid. During each experiment, the pore-scale flow mechanisms were observed and videorecorded, and the mean water saturation was determined with image analysis. Conventional relative permeability, as well as generalized relative permeability coefficients (with the viscous coupling terms taken explicitly into account) were determined with a new method that is based on a B-spline functional representation combined with standard constrained optimization techniques. A simple relationship between the conventional relative permeabilities and the generalized relative permeability coefficients is established based on several experimental sets. The viscous coupling (off-diagonal) coefficients are found to be comparable in magnitude to the direct (diagonal) coefficients over board ranges of the flow parameter values. The off-diagonal coefficients (k rij /Μ j ) are found to be unequal, and this is explained by the fact that, in the class of flows under consideration, microscopic reversibility does not hold and thus the Onsager-Casimir reciprocal relation does not apply. Thecoupling indices are introduced here; they are defined so that the magnitude of each coupling index is the measure of the contribution of the coupling effects to the flow rate of the corresponding fluid. A correlation of the coupling indices with the underlying flow mechanisms and the pertinent flow parameters is established.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 1994-07-01
    Print ISSN: 0169-3913
    Electronic ISSN: 1573-1634
    Topics: Geosciences , Technology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 1995-08-01
    Print ISSN: 0169-3913
    Electronic ISSN: 1573-1634
    Topics: Geosciences , Technology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 1995-06-25
    Description: Steady-state two-phase flow in porous media was studied experimentally, using a model pore network of the chamber-and-throat type, etched in glass. The size of the network was sufficient to make end effects negligible. The capillary number, Ca, the flow-rate ratio, r, and the viscosity ratio, k, were changed systematically in a range that is of practical interest, whereas the wettability (moderate), the coalescence factor (high), and the geometrical and topological parameters of the porous medium were kept constant. Optical observations and macroscopic measurements were used to determine the flow regimes, and to calculate the corresponding relative permeabilities and fractional flow values. Four main flow regimes were observed and videorecorded, namely large-ganglion dynamics (LGD), small-ganglion dynamics (SGD), drop-traffic flow (DTF) and connected pathway flow (CPF). A map of the flow regimes is given in figure 3. The experimental demonstration that LGD, SGD and DTF prevail under flow conditions of practical interest, for which the widely held dogma presumes connected pathway flow, necessitates the drastic modification of that assumption. This is bound to have profound implications for the mathematical analysis and computer simulation of the process. The relative permeabilities are shown to correlate strongly with the flow regimes, figure 11. The relative permeability to oil (non-wetting fluid), kro, is minimal in the domain of LGD, and increases strongly as the flow mechanism changes from LGD to SGD to DTF to CPF. The relative permeability to water (wetting fluid), krw, is minimal in the domain of SGD; it increases moderately as the flow mechanism changes from SGD to LGD, whereas it increases strongly as the mechanism changes from SGD to DTF to CPF. Qualitative mechanistic explanations for these experimental results are proposed. The conventional relative permeabilities and the fractional flow of water, fw, are found to be strong functions not only of the water saturation, Sw, but also of Ca and k (with the wettability, the coalescence factor, and all the other parameters kept constant). These results imply that a fundamental reconsideration of fractional flow theory is warranted. © 1995, Cambridge University Press. All rights reserved.
    Print ISSN: 0022-1120
    Electronic ISSN: 1469-7645
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 1999-01-27
    Print ISSN: 0888-5885
    Electronic ISSN: 1520-5045
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...