ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
  • 1
    Publication Date: 2008-02-29
    Description: A system to record the ultraviolet (UV) spectra of atmospheric global irradiance with the miniature fiber optic spectrometer AvaSpec-256 was developed for continuous computer-aided spectrometry at Tartu Observatory in 2005. As a result, the database of spectra recorded with 15-min-interval round 24 h over 300–400 nm, has been developed. The quantities retrieved from the spectra have been compared with those measured by the Scintec erythemal UV-SET sensor and the Kipp&Zonen narrowband 306 nm sensor. Almost clear and overcast days were selected for comparison. Reliable results on the spectral distribution of the UV global irradiance as well as the integrated daily spectral doses could be obtained at least during the bright half-year. The results were compared with the calculations performed by means of the LibRadtran package. The biases in irradiance were significant at SZA above 70–75°. At dominating larger SZA the recorded values need sophisticated corrections and remain less reliable. At lower latitudes than that of the study site (58.3 degrees), the reliability of the spectrometer is expected to increase due to a smaller contribution of data measured at large SZA. The variations of the ratio of UV-A/UV-B irradiance, retrieved from the spectra, were investigated. Also the covariation of the narrowband 306 nm irradiance and the irradiance integrated over the whole UV-B range was studied. The biases between calculated by means of the LibRadtran package and the measured ratio of UV-A/UV-B irradiance were small at SZA below 70°. At larger SZA the values of the ratio as well as the biases increased, significantly depending on total ozone.
    Electronic ISSN: 1680-7375
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2008-06-27
    Description: A system to record the ultraviolet (UV) spectra of atmospheric global irradiance with the miniature fiber optic spectrometer AvaSpec-256 was developed for continuous computer-aided spectrometry at Tartu Observatory in 2005. As a result, the database of spectra recorded with 15-min-interval round 24 h over 300–400 nm, has been developed. The quantities retrieved from the spectra have been compared with those measured by the Scintec erythemal UV-SET sensor and the Kipp & Zonen narrowband 306 nm sensor. Almost clear and overcast days were selected for comparison. Reliable results on the spectral distribution of the UV global irradiance as well as the integrated daily spectral doses could be obtained at least during the bright half-year. The results were compared with the calculations performed by means of the LibRadtran package. The biases in irradiance were significant at SZA above 70–75°. At dominating larger SZA the recorded values need sophisticated corrections and remain less reliable. At lower latitudes than that of the study site (58.3°), the reliability of the spectrometer is expected to increase due to a smaller contribution of data measured at large SZA. The variations of the ratio of UV-A/UV-B irradiance, retrieved from the spectra, were investigated. Also the covariation of the narrowband 306 nm irradiance and the irradiance integrated over the whole UV-B range was studied. The biases between the UV-A/UV-B irradiances calculated by means of the LibRadtran package and measured with the AvaSpec were small at SZA below 70°. At larger SZA the values of the ratio as well as the biases increased, significantly depending on total ozone.
    Print ISSN: 1680-7316
    Electronic ISSN: 1680-7324
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2012-08-06
    Description: Inter-comparison of data products from simultaneous measurements performed with independent systems and methods is a viable approach to assess the consistency of data and additionally to investigate uncertainties. Within such a context the inter-comparison called Assessment of In Situ Radiometric Capabilities for Coastal Water Remote Sensing Applications (ARC) was carried out at the Acqua Alta Oceanographic Tower in the northern Adriatic Sea to explore the accuracy of in situ data products from various in- and above-water optical systems and methods. Measurements were performed under almost ideal conditions, including a stable deployment platform, clear sky, relatively low sun zenith angles and moderately low sea state. Additionally, all optical sensors involved in the experiment were inter-calibrated through absolute radiometric calibration performed with the same standards and methods. Inter-compared data products include spectral water-leaving radiance Lw (λ), above-water downward irradiance Ed(0+,λ) and remote sensing reflectance Rrs(λ). Data products from the various measurement systems/methods were directly compared to those from a single reference system/method. Results for Rrs(λ) indicate spectrally averaged values of relative differences comprised between −1 and +6%, while spectrally averaged values of absolute differences vary from approximately 6% for the above-water systems/methods to 9% for buoy-based systems/methods. The agreement between Rrs(λ) spectral relative differences and estimates of combined uncertainties of the inter-compared systems/methods is noteworthy.
    Print ISSN: 1812-0784
    Electronic ISSN: 1812-0792
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2012-03-07
    Description: Inter-comparison of data products from simultaneous measurements performed with independent systems and methods is a viable approach to assess the consistency of products and additionally to investigate uncertainties. Within such a context the inter-comparison called Assessment of In Situ Radiometric Capabilities for Coastal Water Remote Sensing Applications (ARC), was carried out at the Acqua Alta Oceanographic Tower in the Northern Adriatic Sea to explore the accuracy of in situ data products from various in- and above-water optical systems and methods. Measurements were performed under almost ideal conditions including: a stable deployment platform, clear sky, relatively low sun zenith angles and moderately low sea state. Additionally, except for one, all optical sensors involved in the experiment were inter-calibrated through a post-field absolute radiometric calibration performed with the same standards and methods. Inter-compared data products include: spectral water-leaving radiance Lw(λ), above-water downward irradiance Ed (0+,λ) and remote sensing reflectance Rrs(λ). Data products from the various measurement systems/methods were directly compared to those from a single reference system/method. Results for Rrs(λ) indicate spectrally averaged values of relative differences comprised between –1 and +6 %, while spectrally averaged absolute values of relative differences vary from approximately 6 % for the above-water systems/methods to 9 % for buoy-based systems/methods. The agreement between Rrs(λ) spectral relative differences and estimates of combined uncertainties of the inter-compared systems/methods is noteworthy.
    Print ISSN: 1812-0806
    Electronic ISSN: 1812-0822
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-04-29
    Print ISSN: 0177-798X
    Electronic ISSN: 1434-4483
    Topics: Geosciences , Physics
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-05-28
    Description: An intercomparison of radiance and irradiance ocean color radiometers (the second laboratory comparison exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: (1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; (2) indoor, laboratory intercomparison using stable radiance and irradiance sources in a controlled environment; (3) outdoor, field intercomparison of natural radiation sources over a natural water surface. The aim of the experiment was to provide a link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether di�erent instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the third phase of LCE-2: The results of the field experiment. The calibration of radiometers and laboratory comparison experiment are presented in a related paper of the same journal issue. Compared to the laboratory comparison, the field intercomparison has demonstrated substantially larger variability between freshly calibrated sensors, because the targets and environmental conditions during radiometric calibration were di�erent, both spectrally and spatially. Major di�erences were found for radiance sensors measuring a sunlit water target at viewing zenith angle of 139� because of the di�erent fields of view. Major di�erences were found for irradiance sensors because of imperfect cosine response of di�users. Variability between individual radiometers did depend significantly also on the type of the sensor and on the specific measurement target. Uniform SI traceable radiometric calibration ensuring fairly good consistency for indoor, laboratory measurements is insu�cient for outdoor, field measurements, mainly due to the di�erent angular variability of illumination. More stringent specifications and individual testing of radiometers for all relevant systematic e�ects (temperature, nonlinearity, spectral stray light, etc.) are needed to reduce biases between instruments and better quantify measurement uncertainties.
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-05-28
    Description: An intercomparison of radiance and irradiance ocean color radiometers (The Second Laboratory Comparison Exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: 1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; 2) Indoor intercomparison using stable radiance and irradiance sources in controlled environment; and 3) Outdoor intercomparison of natural radiation sources over terrestrial water surface. The aim of the experiment was to provide one link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether di�erent instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the activities and results of the first two phases of LCE-2: the SI-traceable radiometric calibration and indoor intercomparison, the results of outdoor experiment are presented in a related paper of the same journal issue. The indoor experiment of the LCE-2 has proven that uniform calibration just before the use of radiometers is highly e�ective. Distinct radiometers from di�erent manufacturers operated by di�erent scientists can yield quite close radiance and irradiance results (standard deviation s 〈 1%) under defined conditions. This holds when measuring stable lamp-based targets under stationary laboratory conditions with all the radiometers uniformly calibrated against the same standards just prior to the experiment. In addition, some unification of measurement and data processing must be settled. Uncertaint of radiance and irradiance measurement under these conditions largely consists of the sensor’s calibration uncertainty and of the spread of results obtained by individual sensors measuring the same object.
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2020-06-04
    Description: A field intercomparison was conducted at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea, from 9 to 19 July 2018 to assess differences in the accuracy of in- and above-water radiometer measurements used for the validation of ocean colour products. Ten measurement systems were compared. Prior to the intercomparison, the absolute radiometric calibration of all sensors was carried out using the same standards and methods at the same reference laboratory. Measurements were performed under clear sky conditions, relatively low sun zenith angles, moderately low sea state and on the same deployment platform and frame (except in-water systems). The weighted average of five above-water measurements was used as baseline reference for comparisons. For downwelling irradiance ( Ed ), there was generally good agreement between sensors with differences of 〈6% for most of the sensors over the spectral range 400 nm–665 nm. One sensor exhibited a systematic bias, of up to 11%, due to poor cosine response. For sky radiance ( Lsky ) the spectrally averaged difference between optical systems was 〈2.5% with a root mean square error (RMS) 〈0.01 mWm−2 nm−1 sr−1. For total above-water upwelling radiance ( Lt ), the difference was 〈3.5% with an RMS 〈0.009 mWm−2 nm−1 sr−1. For remote-sensing reflectance ( Rrs ), the differences between above-water TriOS RAMSES were 〈3.5% and 〈2.5% at 443 and 560 nm, respectively, and were 〈7.5% for some systems at 665 nm. Seabird-Hyperspectral Surface Acquisition System (HyperSAS) sensors were on average within 3.5% at 443 nm, 1% at 560 nm, and 3% at 665 nm. The differences between the weighted mean of the above-water and in-water systems was 〈15.8% across visible bands. A sensitivity analysis showed that Ed accounted for the largest fraction of the variance in Rrs , which suggests that minimizing the errors arising from this measurement is the most important variable in reducing the inter-group differences in Rrs . The differences may also be due, in part, to using five of the above-water systems as a reference. To avoid this, in situ normalized water-leaving radiance ( Lwn ) was therefore compared to AERONET-OC SeaPRiSM Lwn as an alternative reference measurement. For the TriOS-RAMSES and Seabird-HyperSAS sensors the differences were similar across the visible spectra with 4.7% and 4.9%, respectively. The difference between SeaPRiSM Lwn and two in-water systems at blue, green and red bands was 11.8%. This was partly due to temporal and spatial differences in sampling between the in-water and above-water systems and possibly due to uncertainties in instrument self-shading for one of the in-water measurements.
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...