ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
    Publication Date: 1986-01-01
    Print ISSN: 0018-2222
    Electronic ISSN: 1432-119X
    Topics: Biology , Medicine
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Histochemistry and cell biology 84 (1986), S. 509-514 
    ISSN: 1432-119X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary A method is described in which the surface morphology of benign and malignant cervical cells is investigated with a comined light microscope-scanning electron microscope, after the measurement of the DNA content of each individual cell in the same instrument. The suspect cells can thus be identified by an increased aneuploid DNA content (〉5C) and not primarily by morphology. The DNA content was measured, after a quantitative acriflavine-Feulgen staining, by using a microphotometer attached to the combined microscope. It was found that the suspect cells show a different surface morphology compared to normal cells from a benign specimen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The biocompatibility of dense Silastic implants and porous implants made of Estane 5714 F1 polyether urethane, polypropylene oxide, and an HPOE/PBT segmented polyether polyester copolymer was evaluated during an induced Staphylococcus aureus middle ear infection.The middle ear response to infection seemed not to be affected by the presence of implants made of either of the polymers. Light microscopical morphometry and transmission electron microscopy showed degradation of the porous implants under study, but not of Silastic implants, which were invariably surrounded by a fibrous capsule. This finding, combined with the degree of porous implant degradation, the composition of the tissues surrounding the implants, and the tissue/biomaterial interface reactions are consistent with the results obtained in the noninfected middle ear. Round-cell infiltrates however, were predominantly associated with implants made of polypropylene oxide and HPOE/PBT copolymer; while the presence of (phagocytosed) microbial debris was associated with copolymer.The present findings indicate that with respect to implant behavior in infected surroundings Estane is the best porous material, whereas the behavior of Silastic implants did not deviate from that in noninfected ears.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The biocompatibility of porous implants made of Estane 5714 F1 polyether urethane, polypropylene oxide, and a poly(ethylene oxide hydantoin) and poly(tetramethylene terephthalate) segmented polyether polyester copolymer (HPOE/PBT copolymer), which were selected as candidates for an alloplastic tympanic membrane, was assessed after implantation in rat middle ears for periods of up to 1 year. Implantation of the materials led to tissue reactions initially associated with the wound-healing process, whereas after 1 month not only the presence of macrophages and foreign-body giant cells surrounding the implant materials but also implant degradation were characteristic for a foreign-body reaction. Macrophages and foreign-body giant cells dominated the picture of the tissue surrounding polypropylene oxide. The altered morphology of these cells, the persistent infiltration of the implantation sites by exudate cells, and the premature death of five rats in the 1-year group suggest that polypropylene oxide degradation was accompanied by the release of toxic substances. Estane and copolymer degradation did not induce tissue responses reflecting implant toxicity, and tympanic membranes given these alloplasts showed a normal healing pattern. Inclusions in the cytoplasm of macrophages associated with degradation and phagocytosis of all of the polymers under study were found to contain iron, silicon, titanium, and aluminum. Growth of fibrous tissue and bone, the latter into Estane and HPOE/PBT copolymer implants, indicated appropriate implant fixation by tissue, although macrophages and foreign-body giant cells were present as well. Especially the fixation of copolymer by ingrowth of bone seems promising in terms of the amount of bone in the pores and the electron-dense bone/copolymer interface. The latter is indicative for bonding osteogenesis. The HPOE/PBT copolymer is a better candidate for alloplastic tympanic membrane than Estane, and the use of polypropylene oxide cannot be recommended.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 277-293 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The tissue/biomaterial interface reactions of four elastomers - selected as candidates for scaffolding for tympanic membrane tissue in a total alloplastic middle ear prosthesis - were studied at the electron microscopical level after implantation in the rat middle ear. Time-dependent changes in the phagocyte/polymer interface suggested degradation of porous implants made of Estane polyether urethane, polypropylene oxide, and a poly(ethylene oxide hydantoin) and poly(tetramethylene terephthalate) segmented polyether polyester copolymer (HPOE/PBT copolymer), but not of dense Silastic silicone rubber implants. Silastic was always encapsulated in fibrous tissue. Contact between fibrous tissue and HPOE/PBT copolymer or Estane was established in the third month, but fibrous tissue was never seen close to polypropylene oxide. Bone made contact only with Estane and HPOE/PBT copolymer implants. The bone/copolymer interface showed an electron-dense layer morphologically similar to that seen between bone and hydroxyapatite ceramic, suggesting that with respect to bone HPOE/PBT copolymer behaves like a bioactive implant material. The electron-dense layer was absent at the bone/Estane interface. Estane and especially HPOE/PBT copolymer seem to be suitable as alloplastic tympanic membrane because of their interface behavior with respect to fibrous tissue and bone.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 433-453 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The biocompatibility of 11 hydroxyapatite auditory canal-wall prostheses and 4 hydroxyapatite incus prostheses implanted for 4 to 40 months was evaluated by light microscopy, scanning electron microscopy, transmission electron microscopy, and Röntgen microanalysis. These 15 prostheses representing 4% of 375 prostheses, had been removed because of unresolved chronic middle ear infection, residual cholesteatoma, or poor fit. The findings confirmed earlier reports on the biocompatibility of hydroxyapatite in vitro, in animals, and in man. An electron-dense layer was found at the interface with bone and fibrous tissue, and a firm bond between the ceramic and bone at the hydroxyapatite ceramic/bone interface developed. Macropores became filled with bone and fibrous tissue, and the tissue in the individual pores was interconnected. Furthermore the incus prostheses were covered with an epithelium similar to that found in the human middle ear. Findings diverging from those made in other studies were the relatively large amount of exudate in the pores, an apparent increase of degradation during infection, and the accumulation of trace elements in one of the canal-wall prostheses. In all likelihood these three phenomena may be attributed to the unfavorable conditions to which these prostheses were exposed during implantation.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Epithelial reactions to Silastic, Estane polyether urethane, polypropylene oxide, and a poly(ethylene oxide hydantoin) and poly(tetramethylene terephthalate) segmented polyether polyester copolymer were investigated after implantation in tympanic membranes and submucosa of noninfected and Staphylococcus aureus-infected rat middle ears. Porous implants made of Estane and polypropylene oxide were completely covered by tympanic-membrane connective tissue, epidermis, and epithelium in 2 weeks and those made of copolymer in between 2 and 4 weeks postoperatively. Silastic implants, which were dense, were not enveloped by tympanic-membrane tissue but rejected. Starting in the 6th postoperative month the proliferative activity and structure of both the tympanic membrane epithelium and epidermis became normal except for the presence of iron-containing secretory epithelium near polypropylene oxide. After initial swelling caused by the surgical trauma, neither the proliferative activity nor the composition of the epithelium covering submucosal implants was affected by the presence of any of the biomaterials. Infection of middle ears bearing implants induced epithelial reactions similar to those associated with infected middle ears without an implant.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...