We describe the design and performance of compact, low-pass electrical filters, suitable for operation at cryogenic temperatures. The filters are two pole LC filters with a cutoff at ≈100 kHz, an attenuation of −24 dB/octave, and a stop band rejection of −80 dB between 5 and 20 MHz. Their function is to suppress rf voltage noise to sensitive cryogenic detectors. The low-pass filters are realized using surface mounted devices on thin PC boards which can be stacked for maximum packing density. Compact modules containing 14 and 35 filters have been developed and installed in the Infrared Telescope in Space. © 1995 American Institute of Physics.