ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 53 (1998), S. 685-695 
    ISSN: 1572-8943
    Keywords: DSC ; isothermal microcalorimetry ; specific heat capacity ; tissue equivalent liquid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The specific heat capacities (cp) for the brain and muscle equivalent liquids were determined with isothermal heat conduction microcalorimetry (IMC) and differential scanning calorimetry (DSC). IMC was found to afford an accurate technique to measure cp for solid and liquid samples, when an appropriate reference is employed. The accuracy of obtained cp values was estimated to be better than 0.7% with the equivalent liquids. Intercomparison with a conventional isoperibolic calorimeter showed an excellent agreement within the estimated uncertainty of the isoperibolic calorimeter (±3%). Additionally, suitability of different kinds of IMC sample vessels was tested, and the standard electrical calibration procedure of IMC was evaluated through the determination of cp with and without a reference material.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-904X
    Keywords: photoreactivity ; photochemistry ; isothermal microcalorimetry ; nifedipine ; ascorbic acid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. In this study an irradiation cell made as an accessory for an isothermal microcalorimeter is introduced, and its suitability for detection photoreactivity in pharmaceutical solutions and solids is demonstrated. The pharmaceuticals employed are chosen as sample materials to evaluate the usefulness and stability of the irradiation cell. Methods. An irradiation cell has been constructed and tested in an isothermal microcalorimeter with pharmaceutical solutions and solids known to be sensitive to daylight or UV light. Light is produced with an Xe-arc lamp, split into two parts and introduced into calorimetric vessels with optical light cables. One of the vessels containing the reference sample gives the response to the heat absorbed by the material (radiant power), and the other vessel containing the sample material gives the response also to the photoreaction. The two irradiation cells are positioned in the sample sides of two separate twin microcalorimetric units. Results. Nifedipine and L-ascorbic acid were found to be photosensitive in solutions and solid states, the extent of the degradation depending on the irradiation intensity and wavelength. The threshold values of the wavelength for the photoreactions, as well as the wavelengths for the maximum reaction rates, were estimated via the scanning irradiation measurements. The ability of photons with different energies to produce heat in the photosensitive reaction of nifedipine was calculated using constant λ measurements. Conclusions. The technique introduced offers a rapid and versatile method to study the photosensitivity of materials in any state. In the measurements, various conditions can be simulated and thus provide information on the real behavior of materials.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 56 (1999), S. 1305-1310 
    ISSN: 1572-8943
    Keywords: isothermal microcalorimetry ; pharmaceutical substance ; photochemistry ; photolability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A well-known photolabile substance, nifedipine, was used as a sample material to test self-constructed irradiation cells and demonstrate their usefulness in photostability studies. The devices were made as accessories for a commercial isothermal microcalorimeter. Several powder samples containing various amounts of moisture were irradiated with monochromatic light as a scan measurement from 700 to 280 nm, and the heat flow evolved in the photodegradation of nifedipine was determined. According to the results, light does not affect the nifedipine molecule directly, but the photodegradation is a result of the combined effects of moisture and light.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...