  • Gas chromatography  (21)
  • Coupled HPLC-GC  (5)
  • Solvent effects  (4)
  • Column preparation  (2)
  • Coupled HPLC-capillary GC  (2)
  • 1
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, persllylation ; Discussion of variable parameters ; Suggested practical procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 31-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, silylation ; Inertia stable to 350° ; Free acids and bases, simultaneous injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A deactivation procedure is described based on a published method using hexamethyldisilazane in the gas phase. In addition to unusually high inertia and thermostability, the method produces truly neutral columns which allow simultaneous analysis of moderately strong free acids and bases. The silylated columns show their full potential only with on-column injection. Preliminary experimental directions are given; more elaborate directions will become available after extended optimization work.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 197-201 
    ISSN: 1612-1112
    Keywords: Capillary GC ; Co-injection ; Solvent effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Co-injection techniques (introducing additional pure solvent with the sample) were tested to eliminate peak distortion due to partial solvent trapping. Co-injections of solvent identical with the sample solvent were not successful, because first only partial solvent trapping of the strong type could be eliminated and second, there was no practicable method of placing a band of pure solvent ahead of the sample in the column inlet. Successful co-injections have to accept mixing of the sample with the pure solvent. Either the solvent trapping is improved by co-injection of a solvent which enhances solution of the critical solutes in the sample layer, or it creates a phase soaking effect in the stationary phase and reconcentrates broadened bands beyond the flooded inlet. The added solvent must have the appropriate polarity and some of it must remain in the column inlet at least until the sample solvent has completely evaporated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 286-290 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Discrimination due to FID ; Effect of carrier gas flow changes on detector sensitivity ; Hydrogen as carrier gas ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The sensitivity of an FID may change when the carrier gas flow rate changes during a chromatographic run. Sample parts which are eluted at reduced FID sensitivity produce a reduced peak area, hence are discriminated as compared to other components. Sensitivity changes were studied for hydrogen as carrier gas. For the detector tested, differences in the carrier gas flow rates of 1 ml/min shifted the FID sensitivity by 1 to 5% (depending on the fuel gas supply). Thus the stability of the sensitivity is no longer ensured as soon as the carrier gas flow rate is changed manually or by an automatic programmer during an analysis. Sensitivity drifts may also occur during temperature programmed runs with a pressure regulated carrier gas supply since the gas flow through the capillary drops with increasing temperature. Such shifts in the response became noticeable as soon as relatively high carrier gas flow rates combined with long range temperature programmes were used. The typical patterns of such discriminations are shown, closing with a discussion on the possibilities for minimizing such undesired effects.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 525-526 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating ; Filling the column by pressure, not by vacuum ; Device for filling by pressure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 585-586 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass or fused silica ; Adsorptive and catalytic activity ; Distinction of effects ; Discussion of active sites ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0935-6304
    Keywords: Coupled HPLC-GC ; Retention gap ; Partially concurrent solvent evaporation ; Gasoline ; Group-type separation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two-dimensional chromatography of gasoline by on-line coupled HPLC-HRGC, as described in this paper, allows separate GC analysis of paraffins and aromatics. The GC system contains a retention gap of only 10 m length for introducing HPLC fractions of 100 μl volume. This becomes possible through evaporation of part of the solvent during introduction of the HPLC eluent. This “partially concurrent solvent evaporation” technique allows transfer of large volumes of HPLC eluent into relatively short retention gaps, maintaining the full efficiency of the solvent effects in reconcentrating the bands of the early eluted solutes.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 405-407 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Solvent effects ; Solvent trapping ; Phase soaking ; Large sample volumes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 527-528 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Leaching compared to etching ; Leaching by 20% HCI at 240°C ; Metal ions eliminated from glass surface ; Silica layer formed on leached surface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 13-18 
    ISSN: 0935-6304
    Keywords: Gas chromatography, capillary ; Column preparation ; Immobilization of stationary phases ; Procedure for polar phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Whereas the immobilization of apolar silicone phases is essentially understood and mastered, the corresponding treatment of even moderately polar phases remains problematical. Upon attack by peroxide radicals, these phases respond by forming active transformation products rather than by bonding to the support surface or to neighboring molecules. OV-1701 is at present the most polar stationary phase which can reasonably be immobilized. An essential feature of the practical procedure is the prevention of film breakage after coating the inert support surface and before immobilization. Two ways of overcoming this problem are presented.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...