ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Astronomy  (3)
  • MECHANICAL ENGINEERING  (1)
  • recovery  (1)
Collection
Publisher
Years
  • 1
    ISSN: 1573-5117
    Keywords: catch and release ; heart rate ; telemetry ; angle ; recovery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The introduction of ‘Catch and Release’ fishery programs are now widely employed by fisheries managers in most Atlantic Provinces, primarily due to the recent decline of Atlantic salmon stocks on the east coast of Canada. However, there is still considerable debate among special interest groups and regulators as to the effectiveness of the technique. Heart rate telemetry has been utilized as a tool for the assessment of metabolic rate in wild fish by a number of investigators, and was employed in the present study in order to assess recovery following staged angling events in Atlantic salmon. Wild Atlantic salmon were successfully angled at 20 ±2 °C and 16.5 ±1 °C at Noel Paul's Brook, Newfoundland. In addition, hatchery reared Atlantic salmon were angled at the Ontario Ministry of Agriculture and Fisheries Research Station, Alma, Ontario, at a temperature of 8 ±1 °C. Survival rate for the angled salmon was 20% at 20 ± 2 °C; 100± at 16.5 ±1 °C; and 100% at 8 ± 1 °C. Mean resting heart rate for the fish angled at 16.5 °C and 20 ° C was approximately 1.6 and 1.8 times greater than that of fish angled at 8 °C. Heart rate, post angling, was found to increase 1.2 fold in the 8 °C group, 1.3 fold in the 16.5 °C group and approximately 1.15 fold in the 20 °C group. Time to recovery was assessed as a return to observed resting heart rate for each individual fish and was found to be similar for both the 8 °C and 16.5 °C angled groups (approximately 16 h). Although heart rate telemetry in fish is, perhaps, not an ideal measure of metabolic rate, the present study has demonstrated that remote monitoring of heart rate is a good indicator of post exercise physiological activity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: We report on a search for gravitational waves from coalescing compact binaries using LIGO and Virgo observations between July 7, 2009, and October 20. 2010. We searched for signals from binaries with total mass between 2 and 25 Stellar Mass; this includes binary neutron stars, binary black holes, and binaries consisting of a black hole and neutron star. The detectors were sensitive to systems up to 40 Mpc distant for binary neutron stars, and further for higher mass systems. No gravitational-wave signals were detected. We report upper limits on the rate of compact binary coalescence as a function of total mass. including the results from previous LIGO and Virgo observations. The cumulative 90% confidence rate upper limits of the binary coalescence of binary neutron star, neutron star-black hole, and binary black hole systems are 1.3 x 10(exp -4), 3.1 x 10(exp -5), and 6.4 x 10(exp -6)/cu Mpc/yr, respectively. These upper limits are up to a factor 1.4 lower than previously derived limits. We also report on results from a blind injection challenge.
    Keywords: Astronomy
    Type: GSFC.JA.7274.2012 , Physical Review; 85; 8; 082002
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-12
    Description: We report on an all-sky search for periodic gravitational waves in the frequency band 50-800 Hz and with the frequency time derivative in the range of 0 through -6 x 10(exp -9) Hz/s. Such a signal could be produced by a nearby spinning and slightly non-axisymmetric isolated neutron star in our galaxy. After recent improvements in the search program that yielded a 10x increase in computational efficiency, we have searched in two years of data. collected during LIGO's fifth science run and have obtained the most sensitive all-sky upper limits on gravitational wave strain to date. Near 150 Hz our upper limit on worst-case linearly polarized strain amplitude h(sub 0) is 1 x 10(exp -24), while at the high end of our frequency ra.nge we achieve a worst-case upper limit of 3.8 x 10(exp -24) for all polarizations and sky locations. These results constitute a factor of two improvement upop. previously published data. A new detection pipeline utilizing a Loosely Coherent algorithm was able to follow up weaker outliers, increasing the volume of space where signals can be detected by a factor of 10, but has not revealed any gravitational wave signals. The pipeline has been tested for robustness with respect to deviations from the model of an isolated neutron star, such as caused by a low-mass or long.period binary companion.
    Keywords: Astronomy
    Type: LIGO-P1100029-v36 , GSFC.JA.6767.2012
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-12
    Description: We present results from a search for gravitational-wave bursts in the data collected by the LIGO and Virgo detectors between July 7, 2009 and October 20, 2010: data are analyzed when at least two of the three LIGO-Virgo detectors are in coincident operation, with a total observation time of 207 days. The analysis searches for transients of duration approx. 〈 1 s over the frequency band 64-5000 Hz, without other assumptions on the signal wa.veform, polarization, direction or occurrence time. All identified events are c.onsistent with the expected accidental background. We set frequentist upper limits on the rate of gravitational-wave bursts by combining this search with the previous LIGOVirgo search on the data collected "between November 2005 and October 2007. The upper limit on the rate of strong gravita.tional-wave bursts at the Earth is 1.3 events per year at 90% confidence. We also present upper limits on source rate density per yea.r and Mpc3 for sample popula.tions of standard-candle sources. As in the previous joint run, typical sensitivities of the search in terms of the root-sum-squared strain amplitude for these waveforms lie in the range approx 5 x 10(exp -22 Hz(exp-1/2) approx 1 X 10(exp -20) Hz(exp -1/2) . The combination of the two joint runs entails the most sensitive all-sky search for generic gravitational-wave bursts and synthesizes the results achieved by the initial generation of interferometric detectors.
    Keywords: Astronomy
    Type: GSFC.JA.7271.2012
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-13
    Description: The overall operating temperature and efficiency of solar-powered Stirling engines can be improved by adding an alkali metal pool boiler heat transport system to supply heat more uniformly to the heater head tubes. One issue with liquid metal pool boilers is unstable boiling. Stable boiling is obtained with an enhanced boiling surface containing nucleation sites that promote continuous boiling. Over longer time periods, it is possible that the boiling behavior of the system will change. An 800-h life test was conducted to verify that pool boiling with the chosen fluid/surface combination remains stable as the system ages. The apparatus uses NaK boiling on a - 100 + 140 stainless steel sintered porous layer, with the addition of a small amount of xenon. Pool boiling remained stable to the end of life test. The pool boiler life test included a total of 82 cold starts, to simulate startup each morning, and 60 warm restarts, to simulate cloud cover transients. The behavior of the cold and warm starts showed no significant changes during the life test. In the experiments, the fluid/surface combination provided stable, high-performance boiling at the operating temperature of 700 C. Based on these experiments, a pool boiler was designed for a full-scale 25-kWe Stirling system.
    Keywords: MECHANICAL ENGINEERING
    Type: IECEC ''91: Intersociety Energy Conversion Engineering Conference; Aug 04, 1991 - Aug 09, 1991; Boston, MA; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...