    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 2 (1988), S. 77-78 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A Kratos MS-25RFA medium resolution mass spectrometer and a Concept IS high resolution mass spectrometer were used to analyse a range of highly substituted aromatic alcohols for kinetic studies.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1988), S. 377-380 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new inorganic mass spectrometric technique is described which allows sensitive, rapid and economic determination of trace element concentrations and isotope ratios in aqueous samples. This paper illustrates the potential of the technique in one particular application area, namely the measurement of strontium isotope ratios in human blood and urine following ingestion of an enriched stable strontium isotope. The data from a human volunteer experiment illustrate the viability of the analytical method, with measurement precisions of ± 0.2% (1σ) achieved for the isotope ratio in urine samples, which contained approximately 300 ng 86Sr in the volume required for analysis. Measurement precision is limited by counting statistics.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Resonance effects on measured isotope ratios in lead using three-photon one-colour resonance ionization mass spectrometry are discussed. The shape of the ionization signal is considered for the case of a non-monochromatic laser field. The intensity of the laser radiation is adjusted to be low enough not to cause saturation of the transitions. The variation of the measured isotope ratio as a function of laser frequency is considered. It is shown that the deviation of the measured from the expected isotope ratio, for a Lorentzian laser lineshape equals the ratio of the isotope shift to the laser bandwidth. Unfortunately, the background noise in the experiments makes verification of this behaviour difficult for the isotopes of low abundance.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 690-696 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The ion detection process in a discrete-dynode electron multiplier can result in significant mass resolution losses in time-of-flight mass spectrometry (TOF-MS) for higher mass-to-charge (m/z) ion species. This resolution loss is attributed to propagation time delays and signal broadening in the ion detector. This is presumed tobe due to the generation o a distribution of secondary ion species produced initially upon impact of a primary ion with the first ynoe surface of the ion detector. Comparisons are made between the signals produced by a standard discrete dynode ion detector (which amplified the negatively chqrged species produced by impact of a primry ion) and a detector modified to respond to only the positively charged secondary ion species produced by a primary ion impact. Ion signals for higher m/z ions with the standard detector geometry are see to be due to a narrow signal component, most likely due to the generation o secondary electrons and/or very low mass secondary ions (H-), and a broad signal component, apparently due to secondary ions which take signifiant amounts of time to traverse the low potential fields between the first and second detector dynode. This results in ion signal tailing for higher m/z ion species. Numerical subtraction of the ion signal obtained with the standard and modified detector geometries (singly protonated molecular ion species of equine myoglobin) results in an improvement in mass resolution, such that a new adduct ion species (from trifluoroacetic acid) can be resolved.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 697-701 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Results are oresented for various instrumental configurations employed for matrix-assisted laser desorption mass spectrometry. Mass resolution is determined for a linear time-of-flight mass spectrometer for various lengths of the field-free region. A wire ion guide is utilized and is shown to improve ion transport efficiencies for longer field-free regions. It is also determined experimentally that a modest mass resolution increase is often obtained in configurations employing the wire ion guide when compared to the mass resolution obtained with the same geometr without the wire ion guide. Optimal applied potentials are determined for the wire ion guide. No mass dependence on the opitmal applied potential (-100 V) for the wire ion guide is observed for samples of equine myoglobin (MW 16 951.5 Da) and a bacterial protease (MW 27 228.4 Da). The optimal applied voltage was also found to b identical (-100 V) for the singly through quadruply charged molecular ion species of rabbit gamma globulin (MW ≍ 150 000 Da). It is shown that a 2 m flight tube with a wire ion guide provides better signal-to-noise mass spectra than a 1 m flight tube without the wire ion guide and can more than double the mass resolution obtainable. Utilization obtainable. Utilization of a 4 m flight tube gives minimal mass resolution enhancement at the expense of signal-to-noise.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0095-9898
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The Fast Atom Bombardment mass spectra of a number of xanthane dyes are reported. These dyes are insufficiently volatile to give spectra by conventional electron impact ionization. Fragmentation pathways have been determined by metastable linked scan techniques and accurate masses obtained by peak matching. The xanthane dyes may be readily identified from their FAB spectra by the presence of characteristic ions.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 22 (1987), S. 647-650 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    BioEssays 17 (1995), S. 803-812 
    ISSN: 0265-9247
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Endosperm is emerging as a system for investigating the genetic control of wall placement and deposition in plant development. Development of endosperm progresses in distinct stages from a wall-less syncytial stage to a cellular stage that is entirely typical of plant meristems where the division plane is predicted by a preprophase band of microtubules (PPB) and cytokinesis is completed by formation of a cell plate in association with a phragmoplast. Four developmentally different types of walls, each associated with a different microtubule system, are sequentially produced: (1) free growing walls deposited in the absence of mitosis and phragmoplasts; (2) walls guided by cytoplasmic phragmoplasts formed adventitiously in the absence of mitosis; (3) walls formed by interzonal phragmoplasts in a cell cycle that lacks PPBs; and (4) wall deposition driven by interzonal phragmoplasts in a cycle that includes PPBs. We are using methods of differential screening to isolate cDNA clones corresponding in temporal and spatial pattern to the types of wall development, and are studying mutants for clues to the genetic controls of wall development.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 17 (1986), S. 351-354 
    ISSN: 0377-0486
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: 15NH4ReO4 was synthesized and the Raman spectrum recorded at various temperatures between 10 and 300 K. 15N isotopic shifts of both internal and external modes of the ammonium ion relative to 14NH4ReO4 were observed. The temperature dependence of the external modes was studied. The librational lattice mode associated with the ammonium ion disappeared above about 180 K. At this temperature anomalies were observed in the temperature dependence of the perrhenate ion lattice modes.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...