ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0935-6304
    Keywords: On-line extraction ; Large volume introduction ; Capillary gas chromatography ; Atomic emission detection ; Solvent venting ; Pesticides ; Ground water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The on-line coupling of a liquid-liquid extraction system with capillary gas chromatography using atomic emission detection (GC-AED) has been studied. The required large volumes of about 100 μl of an iso-octane solution can be introduced into the GC-AED system by using the AED solvent vent and a solvent vapor exit in front of the capillary analytical column. Test solutions containing several pesticides were detected using the carbon, chlorine, nitrogen and sulfur channels. Analyte detectability (in concentration units) was improved significantly and low concentractions of the test compounds could be determined (1-5 ng/ml). Aqueous samples were on-line extracted and analyzed. The precision of the large-volume injection itself as well as the total extraction-GC-AED system was satisfactory (RSD of ca. 2 and 4%, respectively). As a real-life application, several ground water samples were screened.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 495-500 
    ISSN: 0935-6304
    Keywords: CZE ; mobility ratio ; migration time prediction ; mathematical model ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The electrophoretic mobility ratio (R value) of any two ions is constant and independent of the capillary type and electrophoretic conditions if their electrical charges and hydration radii are constant. The use of strong acid salts and quaternary ammonium salts is therefore proposed for the determination of R values. Such analytes are called markers. The following determinations can be carried out: (i) the determination of the migration time corresponding to the electroosmotic flow (EOF) in any capillary under any electrophoretic condition by measuring the migration times of two markers in the condition studied (useful when the EOF is weak); (ii) the determination of the migration time of an analyte in any capillary by knowing the migration time of the markers in the capillary studied. If the pH is changed and the ionization of the analyte is pH dependent, the resulting migration time for the analyte can be calculated. The constancy of the mobility ratios of seven markers was checked experimentally at eight different pH values (between pH 3 and 10), at three temperatures, and for two buffer concentrations. The predicted and experimental migration times were also compared in two different types of capillaries.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Capillary GC ; Continuous liquid-liquid extraction ; Environmental applications ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The applicability of a liquid-liquid extraction system which is coupled on-line with a capillary gas chromatograph was studied for environmental and ecotoxicological analyses. The optimized and automated system was used for the determination of apolar and rather non-volatile organic compounds in aqueous samples. Relevant aspects of sample introduction, phase separation and selection of extraction solvent are discussed. Three routine-tipe applications are described, viz. an improved method for the determination of hexachlorocyclohexanes in ground water and the determination of the so-called NCC-ether and ACC-ether in ecotoxicological studies. Depending on the application studied, the concentration levels varied from 0.1 to 6000 μg/I, using ECD and/or FID detection. Typical coefficients of variation obtained with the total extraction-GC procedure were 2-25%.The system was found to be rugged, it saves time compared with set-ups involving off-line liquid-liquid extraction and considerably reduces the manual work load.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0935-6304
    Keywords: Capillary GC ; On-line extractive alkylation ; On-line acylation ; Carboxylic acids ; Amines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Gas chromatographic procedures are described for the determination of carboxylic acids and chlorinated anilines in water samples.Propionic acid and 2,6-difluorobenzoic acid in aqueous solution have been simultaneously alkylated and extracted by means of a continuous two-phase reaction system, and then quantitated by on-line coupled capillary gas chromatography; tetrahexyl-ammonium hydrogen sulfate was used as phase transfer catalyst and pentafluorobenzyl bromide as reagent.A factorial design approach was used to optimize on-line derivatization of aqueous propionic acid with regard to pH and concentration of phase transfer catalyst. Alkylation and extraction, under optimized conditions, followed by quantitation of the pentafluorobenzyl ester by flame ionization detection furnished a linear calibration for concentrations between 0.1 and 10 μg/ml. The relative standard deviation was 9-15 %.The continuous two-phase reaction system was also used to determine (chlorinated) anilines present in water at concentrations of 0.1-1 μg/ml; pentafluorobenzoyl chloride was used as reagent and analysis was performed by capillary gas chromatography with flame ionization or electron capture detection. The on-line acylation of p-chloroaniline was optimized with regard to pH, reagent concentration, and reaction time.The on-line reaction system worked satisfactorily for both applications, although excess reagent caused some problems with the chromatography.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1040-7685
    Keywords: capillary GC ; reversed-phase LC ; on-line coupling ; solvent vapor exit ; pressure-balanced carrier gas system ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A large-volume introduction system for capillary gas chromatography (GC) is described which can be coupled on-line with reversed-phase liquid chromatography (LC) using 2 mm i.d. LC columns. An on-column interface with a special retention gap, coated with a very thin film (0.02 μm) of Carbowax was used. Insertion of a solvent vapor exit before the analytical gas chromatography column allowed the solvent evaporation rate for an azeotropic acetonitrile/water mixture (84:16, v/v) to increase from 20 to 175 μL min-1 at 91°C and 150 kPa inlet pressure. A volume of 200 μL of this mixture containing phenanthrene and the potential basic drug eltoprazine, could be injected into the retention gap at introduction rates up to 200 μL min-1, under partially concurrent solvent evaporation conditions. Repeatability (CV = 2.4%) and linearity (at least 10-1000 ng mL-1) were satisfactory. The Carbowax-coated retention gap has a relatively large retention power for the polar solute. This means that the solvent can be completely evaporated through the vapor exit without loss of analyte. With apolar solutes, losses will occur if evaporation is unduly prolonged. In order to allow the use of a nitrogen-phosphorus detector, a special pressure-balanced carrier gas circuit was designed and tested for total solvent-free performance of the detector. With this set-up, 150 μL injections of eltoprazine in the acetonitrile/water azeotrope were made at an introduction rate of 200 μL min-1. No traces of acetonitrile were detected, while analyte detectability was 20-fold higher than with the FID.Finally, the practicability of reversed-phase LC-GC was demonstrated by on-line heart-cutting of the phenanthrene-containing fraction from a 2 mm i.d. LC column using acetonitrile/water (84:16, v/v) as eluent, and analyzing it by capillary GC-FID.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-07-27
    Description: Key points this analysis will address: 1) What physically is going on in the cloud when there is a jump in lightning? -- Updraft variations, Ice fluxes 2) How do these processes fit in with severe storm conceptual models? 3) What would this information provide an end user? --Relate LJA to radar observations, like changes in reflectivity, MESH, VIL, etc. based multi -Doppler derived physical relationships
    Keywords: Meteorology and Climatology
    Type: M12-2364 , American Meteorological Society (AMS) Annual Meeting; 6 = 10 Jan 2013; Austin, TX; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-19
    Description: The Deep Convective Clouds and Chemistry (DC3) field campaign investigates the impact of deep, midlatitude convective clouds, including their dynamical, physical and lighting processes, on upper tropospheric composition and chemistry. DC3 science operations took place from 14 May to 30 June 2012. The DC3 field campaign utilized instrumented aircraft and ground ]based observations. The NCAR Gulfstream ]V (GV) observed a variety of gas ]phase species, radiation and cloud particle characteristics in the high ]altitude outflow of storms while the NASA DC ]8 characterized the convective inflow. Groundbased radar networks were used to document the kinematic and microphysical characteristics of storms. In order to study the impact of lightning on convective outflow composition, VHF ]based lightning mapping arrays (LMAs) provided detailed three ]dimensional measurements of flashes. Mobile soundings were utilized to characterize the meteorological environment of the convection. Radar, sounding and lightning observations were also used in real ]time to provide forecasting and mission guidance to the aircraft operations. Combined aircraft and ground ]based observations were conducted at three locations, 1) northeastern Colorado, 2) Oklahoma/Texas and 3) northern Alabama, to study different modes of deep convection in a variety of meteorological and chemical environments. The objective of this paper is to summarize the Alabama ground operations and provide a preliminary assessment of the ground ]based observations collected over northern Alabama during DC3. The multi ] Doppler, dual ]polarization radar network consisted of the UAHuntsville Advanced Radar for Meteorological and Operational Research (ARMOR), the UAHuntsville Mobile Alabama X ]band (MAX) radar and the Hytop (KHTX) Weather Surveillance Radar 88 Doppler (WSR ]88D). Lightning frequency and structure were observed in near real ]time by the NASA MSFC Northern Alabama LMA (NALMA). Pre ]storm and inflow proximity soundings were obtained with the UAHuntsville mobile sounding unit and the Redstone Arsenal (QAG) morning sounding.
    Keywords: Meteorology and Climatology
    Type: M12-2056 , 93rd American Meteological Society (AMS) Annual Fall Meeting 2012; Jan 06, 2013 - Jan 10, 2013; Austin, TX; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-19
    Description: The presence and rates of total lightning are both correlated to and physically dependent upon storm updraft strength, mixed phase precipitation volume and the size of the charging zone. The updraft modulates the ingredients necessary for electrification within a thunderstorm, while the updraft also plays a critical role in the development of severe and hazardous weather. Therefore utilizing this relationship, the monitoring of lightning rates and jumps provides an additional piece of information on the evolution of a thunderstorm, more often than not, at higher temporal resolution than current operational radar systems. This correlation is the basis for the total lightning jump algorithm that has been developed in recent years. In order to become a viable option for operational forecasters to incorporate into their severe storm monitoring process, the total lightning jump must be placed into the framework of several severe storm conceptual models (e.g., radar evolution, storm morphology) which forecasters have built through training and experience. Thus, one of the goals of this study is to examine and relate the lightning jump concept to often used radar parameters (e.g., dBZ vertical structure, VIL, MESH, MESO/shear) in the warning environment. Tying lightning trends and lightning jump occurrences to these radar based parameters will provide forecasters with an additional tool that they can use to build an accurate realtime depiction as to what is going on in a given environment. Furthermore, relating the lightning jump concept to these parameters could also increase confidence in a warning decision they have already made, help tip the scales on whether or not to warn on a given storm, or to draw the forecaster s attention to a particular storm that is rapidly developing. Furthermore the lightning information will add vital storm scale information in regions that are not well covered by radar, or when radar failures occur. The physical basis for the lightning jump algorithm in relation to severe storm dynamics and microphysics is a key component that must be further explored. Many radar studies have examined flash rates and their relation to updraft strength, updraft volume, precipitation -sized ice mass, etc.; however, very few have related the concept of the lightning jump and manifestation of severe weather to storm dynamics and microphysics using multi -Doppler and polarimetric radar techniques. Therefore, the second half of this study will combine the lightning jump algorithm and these radar techniques in order to place the lightning jump concept into a physical and dynamical framework. This analysis includes examining such parameters as mixed phase precipitation volume, charging zone, updraft strength and updraft volume. Such a study should provide increased understanding of and confidence in the strengths and limitations of the lightning jump algorithm in the storm warning process.
    Keywords: Meteorology and Climatology
    Type: M12-2002 , 93rd Annual American Meteorological Society (AMS) Meeting; Jan 06, 2013 - Jan 10, 2013; Austin, TX; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-19
    Description: On April 27, 2011, the southeastern United States was raked with several episodes of severe weather. Numerous tornadoes caused extensive damage, and tragically, the deaths of over 300 people. In Alabama alone, there were 61 confirmed tornados, 4 of them produced EF5 damage, and several were on the ground an hour or more with continuous damage tracks exceeding 80km. The use of Doppler radars covering the region provided reflectivity and velocity signatures that allowed forecasters to monitors the severe storms from beginning to end issuing hundreds of severe weather warnings throughout the day. Meteorologists from the the NWS performed extensive surveys to assess the intensity, duration, and ground track of tornadoes reported during the event. Survey activities included site visits to the affected locations, analysis of radar and satellite data, aerial surveys, and interviews with eyewitnesses. Satellite data from NASA's MODIS and ASTER instruments played a helpful role in determining the location of tornado damage paths and in the assessment. High resolution multispectral and temporal composites helped forecasters corroborate their damage assessments, determine starting and ending points for tornado touchdowns, and helped to provide forecasters with a better big-picture view of the damage region. The imagery also helped to separate damage from the April 27th tornados from severe weather that occurred earlier that month. In a post analysis of the outbreak, tornado damage path signatures observed in the NASA satellite data have been correlated to "debris ball" signatures in the NWS Doppler radars and a special ARMOR dual-polarization radar operated by the University of Alabama Huntsville during the event. The Doppler radar data indicates a circular enhanced reflectivity signal and rotational couplet in the radial velocity likely associated with the tornado that is spatially correlated with the damage tracks in the observed satellite data. An algorithm to detect and isolate the "debris ball" from precipitation signatures in the dual polarization radar data has been developed and verified using the NASA damage track data.
    Keywords: Meteorology and Climatology
    Type: M11-0946 , 2011 AGU Fall Meeting; Dec 05, 2011 - Dec 09, 2011; San Francisco, CA; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-13
    Description: The ultraviolet (1150 - 2850 A) spectra of a number of active galactic nuclei (AGNs) observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) have been used to study the properties of the Galactic halo. The objects that served as probes are 3C 273, PKS 0454-220, Pg 1211+143, CSO 251, Ton 951, and PG 1351+640. The equivalent widths of certain interstellar ions have been measured, with special attention paid to the C IV/C II and Si IV/Si II ratios. These ratios have been intercompared, and the highest values are found in the direction of 3C 273, where C IV/C II = 1.2 and Si IV/Si II greater than 1. These high ratios may be due to a nearby supernova remnant, rather than to ionized gas higher up in the Galactic halo. Our data give some support to the notion that QSO metal-line systems may arise from intervening galaxies which contain high supernova rates, galactic fountains, and turbulent mixing layers.
    Keywords: ASTRONOMY
    Type: Astrophysical Journal, Part 1 (ISSN 0004-637X); 437; 2; p. 630-637
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...