ISSN:
0021-9304
Schlagwort(e):
Chemistry
;
Polymer and Materials Science
Quelle:
Wiley InterScience Backfile Collection 1832-2000
Thema:
Medizin
,
Technik allgemein
Notizen:
Bioelectric charge transfer at the blood-wall interface may be a crucial factor affecting thrombosis on implant materials. A program of studies was conducted to determine the electrokinetic and other physical properties of a wide spectrum of materials including organic polymers, metals, inorganics, heterogeneous compounds, and animal tissue. From these tests, materials were selected for in-vivo cannulation experiments. In this manner, a search was made to find a correlation between surface charge characteristics and thrombosis on cardiovascular implant materials. It was found that materials exhibiting a substantial positive charge were prone to rapid thrombosis. No clear correlation can be stated, as yet, regarding the thrombogenecity of highly charged negative surfaces or slightly charged surfaces. However, many heterogeneous materials have exhibited prolonged in-vivo patency. It appears necessary to isolate surface effects from volumetric effects to seek the role of bioelectric charge transfer in blood thrombus formation.
Zusätzliches Material:
9 Ill.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1002/jbm.820020105
Permalink