ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (412)
  • Wiley-Blackwell  (412)
  • American Institute of Physics
  • Springer Nature
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 400-404 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Low temperature plasma etching ; Polymer film on the inner surface from organosilicone monomer ; Flexibility of this new method discussed ; Discharge chamber described ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel method is described for the preparation of stable glass capillary columns (glass open tubular columns), including the etching and formation of a polymer film on the inner glass capillary surfaces. The approach used here is based on low-temperature plasma etching and polymerization. Under the influence of a field of radio frequency discharge, low pressure gases of fluoric compounds, introduced into the glass capillary tube, generate excited fluorine radicals which etch the inner surface. The plasma of organosilicone monomer in the glass capillary yields a uniform polymerized film on the inner surface. The resultant material functions as a good stationary phase for glass capillary gas chromatography (GC2). The inner surfaces treated with such a plasma, can be studied by means of a scanning electron microscope (SEM). The flexibility of this method permits the use of various stationary phases and surface modification.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Thermodynamic properties measured, interaction energy vapour polymers ; Precise Vgº-data measured ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The interaction energies (X1) between the polymers polypropylene, poly(vinylidene chloride), sulphonyldiphenyl formaldehyde resin and poly(vinyl pyrrolidone) and the solvents toluene, ethylbenzene, isopropylbenzene, ortho, meta, and para-xylene are determined by gas chromatography. As shown in earlier publications, this technique for the determination of X1, can be extended to similar systems of theoretical as well as of practical importance, although the selection of the present systems was primarly made on the fact that these systems are of industrial interest and have not so far been investigated by gas-liquid chromatography. The studies were carried out at two temperatures and the results obtained show a decrease of X1 with an increase of temperature.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 253-256 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Thermodynamic data determination ; Diffusivity and activation energy, measured and calculated for selected polypropylene solvent systems ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A thorough survey of the past and current available literature shows that the diffusion of the solvents toluene, ethylbenzene, ortho-, meta-, and para-xylenes in polypropylene has not been studied so far, although such studies find practical applications in various industrial problems. Diffusitives and the activation energies of the above mentioned solvents in polypropylene were determined in the temperature range of 45-120°C by gas chromatography. The values obtained in this communication compare fairly with those determined by conventional techniques for analogous systems, confirming the reliability of the gas chromatography as a powerful tool for diffusion measurement and the authenticity of the data presented herein.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed columns ; Glass transition temperatures of 3 polymers ; Polystyrene ; Poly(vinyl chloride) ; Poly(methyl methacrylate) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The glass transition temperatures, Tg, of polystyrene, poly (vinyl chloride) and poly(methyI methacrylate) have been determined from gas chromatographic measurements using n-hexane, n-heptane, meta-xylene and para-xylene solvents. The glass transition temperatures were detected on the z-shaped retention diagrams which were produced from the plot of the logarithm of the specific retention volumes of the above-mentioned solvents against the reciprocal of temperature, i.e. log Vgº vs. 1/T. The glass transition temperature is specified by the temperature where the slope of log Vgº vs. 1/T changes abruptly. The observed glass transition temperature of polystyrene produced by this technique was found to be in good agreement with those produced by other techniques such as the differential scanning colorimeter.The industrial importance of the glass transition temperature, Tg, might be due to the dramatic changes in the physical properties of the polymer, such as hardness and elasticity, which take place in the vicinity of this temperature. However, perfectly crystalline polymers do not exhibit glass transitions, because their chains are incorporated in regions of three-dimensional order, called crystallites. Completely amorphous polymers and semi-crystalline polymers usually exhibit both glass transition and melting.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; dead time ; multiparametric least-squares adjustment ; homologous series ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---In reversed phase liquid chromatography (RP-HPLC), the validity of a multiparametric non-linear least-squares regression iterative method for the determination of the column dead time tM and the regression parameter (slope b), based on the use of alkan-2-ones, alkyl aryl ketones, and 1-nitroalkanes has been evaluated. The determination of tM and b has been extensively studied for two mobile phase systems acetonitrile-water and methanol-water on seven octadecyl-C18 and one octyl C8 analytical columns. The calculated tM and b values were compared with those obtained by Guardino's and Grobler's methods. The influence exerted thereon by the nature of the homologous series, the mobile phase composition, and the packing materials were investigated.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 45-46 
    ISSN: 0935-6304
    Keywords: Gel filtration ; Plasmid ; TSKgel G6000PW ; Rapid purification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 198-200 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic capillary chromatography ; Capillary electrophoresis ; Nitroaromatics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 137-140 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, Micro-HPLC ; Purpurea glycosides ; Digitalis purpurea ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A micro high-performance liquid chromatographic (micro-HPLC) method was developed for the determination of purpurea glycoside A, purpurea glycoside B, and glucogitaloxin in Digitalis purpurea leaves. The extract of dry leaf powder was applied to a Sep-Pak silica cartridge followed by preparative thin-layer chromatography prior to micro-HPLC analysis. The analysis was performed on an ODS micro column, using acetonitrile-methanol-water (21:20:45) and ultraviolet detection (220 nm). The amounts of purpurea glycoside A, purpurea glycoside B, and glucogitaloxin per 100 mg of dry leaf powder were estimated to be 52.6, 50.7, and 108.6 μg, respectively.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 602-605 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Analytical HPLC ; On-line sample preparation ; Anti-estrogen ; Tamoxifen ; Tamoxifen metabolites ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 360-361 
    ISSN: 0935-6304
    Keywords: Pyrolysis gas chromatography ; Fused silica open tubular column ; Crude drugs ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...