ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Key words: Small rats — Bone mineral density — Bone mineral content — Dual energy X-ray absorptiometry — Methodological evaluation  (1)
  • Springer  (1)
  • American Chemical Society
Collection
Publisher
  • Springer  (1)
  • American Chemical Society
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 67 (2000), S. 455-459 
    ISSN: 1432-0827
    Keywords: Key words: Small rats — Bone mineral density — Bone mineral content — Dual energy X-ray absorptiometry — Methodological evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract. The feasibility of dual energy X-ray absorptiometry (DXA) using the Norland XR-26 Mark II bone densitometer for measurements of bone mineral content (BMC) and bone mineral density (BMD) in small rats was evaluated. Thirty-two young, isogenic, Lewis rats (weights from 119 g to 227 g) were used; normal rats (n = 7) and rats with low BMD obtained from three different vitamin D-depleted models (n = 25). DXA measurements were performed using the special software for small animals. Duplicate scans of excised femurs performed at 2 mm/second (pixel size of 0.5 mm × 0.5 mm) were very precise measurements with a coefficient of variation (CV) below 1.6% in animals with normal BMD; in rats with low BMD, the CV was significantly higher (P= 0.02–0.04), 7.8% and 4.4% for BMC and BMD, respectively. Regression analysis demonstrated that these measurements were related to the ash weight (R2 〉 98.6%). The CV for measurements of the lumbar spine at 10 mm/second (pixel size 0.5 mm × 0.5 mm) was 2.6% and 2.2% for BMC and BMD, respectively in rats with normal BMD, and again higher (P= 0.03–0.14) in rats with low BMD, 7.3% and 4.7%, respectively, for BMC and BMD. Even though low CVs were obtained for total body duplicate scans (scan speed of 20 mm/second and a pixel size of 1.5 mm × 1.5 mm), the measurements were problematic for accuracy because of an overestimation of both BMC and the area of bone. Using these scan parameters the measurements of total body bone mineral could not be recommended in small rats with low BMD.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...