ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (401)
  • Springer  (240)
  • American Chemical Society  (81)
  • Wiley  (33)
  • American Institute of Physics (AIP)  (30)
  • Springer Nature  (17)
  • National Academy of Sciences
  • Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics  (364)
  • Electrical Engineering, Measurement and Control Technology  (40)
Collection
  • Articles  (401)
Publisher
Journal
Topic
  • 1
    Publication Date: 2017-10-23
    Print ISSN: 1944-8244
    Electronic ISSN: 1944-8252
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Focusing optics have been installed on the 5.0 T Wiggler beam line of the SRS at Daresbury Laboratory for use with x-ray diffraction measurements of surfaces and interfaces. A significant increase in the flux has been achieved without excessive degradation of the resolution in the vertical plane. The full width at half-maximum of the focused image compares well with the predictions of ray tracing analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 3178-3183 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design and operation of a gas aggregation source is described. The source combines the attributes of high-temperature operation (enabling preparation of transition metal clusters), mass selection, ultrahigh vacuum compatibility, and transportability. This makes it ideally suited to in situ studies such as scanning tunneling microscope or synchrotron radiation experiments. Data are presented to illustrate the performance of the source; recent results obtained in synchrotron radiation studies are highlighted. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 1853-1857 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design and operation of a high temperature gas aggregation source, capable of in situ deposition of mass-selected atomic clusters of transition metals onto a substrate in an ultrahigh vacuum chamber, is described. Mass-selection is achieved by an ultrahigh mass quadrupole filter operating at masses up to 3×104 amu. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 2048-2052 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A first adaptive x-ray mirror prototype was built in 1992 and is now installed on the ESRF beamline 2 (Materials Science). This system consists of a water-cooled 1 m long Pt-coated Si mirror, supported by two rows of 11 piezoelectric actuators. The shape of the mirror is continuously monitored by an optical analyzer; its readout being used by a feedback loop in a real-time algorithm. A workstation associated to real-time electronics calculates the relevant parameters for driving the actuators as a function of both the desired shape and the possible thermal deformation due to the incident beam. Preliminary experiments carried out on the wiggler beamline showed that the system runs correctly: the feedback loop permits a control of the mirror shape in the microrad range at a frequency of 10 Hz. Various shapes (cylinder, parabola, or ellipse) can be produced at will to within the above accuracy. The different components of the device are described and the alignment and calibration procedures are discussed. The first results dealing with the properties of the reflected beam (size, divergence, and shape) versus both the calibration quality and the incoming power are presented. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 4119-4126 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design, construction and operation of a tomographic imaging system on the Compact Toroid Injection Experiment is described. The system measures the total radiated power over energies from visible light up into the extreme ultraviolet. It then reconstructs two dimensional profiles from the data. The reconstruction routine is based on a method known as second order regularization which finds a compromise between smoothness and fit to the data. This method was found to have the best overall fidelity to test images. The hardware and overall reconstruction were calibrated using two different sources. First results from the system under real experimental conditions are presented. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 1624-1626 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An instrument is described which can obtain x-ray spectral power measurements utilizing the diffraction pattern produced when x rays pass through a slit. Traditionally, these types of measurements yielding low to moderate spectral resolution have been made with filtered x-ray diodes or with a transmission grating. The instrument described below has several advantages over filtered x-ray diodes in determining the spectral power profile such as an insensitivity to surface contamination. In addition, this instrument does not require the use of filters which can be destroyed during a shot making absolute measurements difficult and very time consuming. The advantages over a transmission grating system include cost, mechanical robustness, and fewer components which require spectral calibration. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 2012-2015 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A technique is described to determine the spatial x-ray flux emitted from a hohlraum wall and subsequently transmitted through a diagnostic hole. This technique uses x-ray diodes, bolometers, and a time-resolved pinhole camera to determine the spatial flux of x rays emitted through a hohlraum's diagnostic hole. The primary motivation for this analysis was the relatively long duration, nearly 100 ns, of the x-ray drive present in z-pinch driven hohlraums. This radiation causes plasma to ablate from the hohlraum walls surrounding the diagnostic hole and results in a partial obscuration that reduces the effective area over which diagnostics view the radiation. The effective change in area leads to an underestimation of the wall temperature when nonimaging diagnostics such as x-ray diodes and bolometers are used to determine power and later to infer a wall temperature. An analysis similar to the one described below is then necessary to understand the radiation environment present in x-ray driven hohlraums when these diagnostics are used and hole closure is important. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 1256-1260 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The article presents the design and the first results of a new eight camera, soft x-ray (SXR) and bolometric tomography which has been installed in RFX, a large (R=2 m, a=0.46 m), high current reverse field pinch experiment operating in Padova. The main features of the diagnostic, which has been designed with standards compatible with the requirements of large fusion experiments, are: (a) it allows simultaneous reconstruction of both SXR and total radiation emissivity structures with high spatial and time resolution (bandwidth up to 200 kHz for SXR and 10 kHz for bolometry). Moreover, computer controlled remote actions which interchange up to five material filters in front of the detectors allow the exploration of different energy ranges; (b) it can be easily decoupled from the machine without breaking the main vacuum and can be operated during first wall baking up to 300 °C thanks to a cooling circuit; (c) the detection chain is designed to measure very low signals [in the order of 1 nA for SXR diodes and of 100 μV for bolometers]; (d) it is equipped with a VME based 1 MHz data acquisition system which allows on-line processing of a large amount of data. To accomplish these features the diagnostic consists of eight fully remotely controlled manipulators which can insert eight photocameras, carrying 78 top-rated Si SXR and 48 miniaturized metal film bolometric detectors in their operating positions. Initial results are presented. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The article presents the design and the first results of a new eight camera, soft x-ray (SXR) and bolometric tomography which has been installed in RFX, a large (R=2 m, a=0.46 m), high current reverse field pinch experiment operating in Padova. The main features of the diagnostic, which has been designed with standards compatible with the requirements of large fusion experiments, are: (a) it allows simultaneous reconstruction of both SXR and total radiation emissivity structures with high spatial and time resolution (bandwidth up to 200 kHz for SXR and 10 kHz for bolometry). Moreover, computer controlled remote actions which interchange up to five material filters in front of the detectors allow the exploration of different energy ranges; (b) it can be easily decoupled from the machine without breaking the main vacuum and can be operated during first wall baking up to 300 °C thanks to a cooling circuit; (c) the detection chain is designed to measure very low signals [in the order of 1 nA for SXR diodes and of 100 μV for bolometers]; (d) it is equipped with a VME based 1 MHz data acquisition system which allows on-line processing of a large amount of data. To accomplish these features the diagnostic consists of eight fully remotely controlled manipulators which can insert eight photocameras, carrying 78 top-rated Si SXR and 48 miniaturized metal film bolometric detectors in their operating positions. Initial results are presented. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...