ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Physics  (17)
  • Analytical Chemistry and Spectroscopy  (12)
  • General Chemistry  (7)
  • GEOPHYSICS  (2)
  • 1980-1984  (34)
  • 1960-1964  (4)
Collection
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 73 (1961), S. 7-11 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Kurzlebige Reaktionszwischenprodukte lassen sich beobachten, indem man die Reaktion durch einen Photolyseblitz startet und das Absorptionsspektrum der Photolyseprodukte aufnimmt. Die Leistungsfähigkeit dieser Blitzlicht-Photolyse wird am Beispiel der Jod-Rekombination im Gaszustand und der chinon-sensibilisierten Oxydation mit O2 in Lösung aufgezeigt.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 76 (1964), S. 821-822 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 75 (1963), S. 422-422 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1982), S. 81-85 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Phenol and five acyclic isomeric compounds have been investigated using electron impact and field ionization techniques, mass analysed ion kinetic energy spectrometry and collision induced dissociation mass analysed ion kinetic energy spectrometry. The kinetic energy release data corresponding to the elimination of carbon monoxide from the molecular ions show that at least two structures of the reactant ion are involved. The electron impact and field ionization collision induced dissociation mass analysed ion kinetic energy spectra indicate that under electron impact conditions, the phenol ion partially isomerizes to another ion structure. An isomerization of about 40% to the structure of cis-2-hexen-4-yn-1-al is in good accordance with the spectral data.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1982), S. 331-334 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Translational energy release measurments on metastable ions are used in the comparison of the structures of isomeric ions. Metastable ions, m2+, formed from m1+ ions as the result of a high energy process in the ion source are compared with isomeric metastable ions formed as daughters from fragmentation of metastable m1+ ions in a field. In the case of o-, m- and p-nitrophenol the structure of the [C5H5O]+ ions formed from [C6H5O]+ ions by these two independent methods is different as verified by comparison of the behaviour of [C5H5O]+ ions formed from several other compounds.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1981), S. 101-114 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Using nitrobenzene as an example, various ways in which a contemporary mass spectrometer can be utilized to yield a wealth of information about the compound studied are reviewed. Applying a variety of different techniques and procedures, in addition to the conventional low resolution mass spectrum, the following nitrobenzene spectra have been obtained: collision induced dissociation mass spectrum, mass analysed ion kinetic energy spectra, collision induced dissociation mass analysed ion kinetic energy spectra, spectra obtained at constant B/E, spectra obtained at constant B2/E, high voltage scans of metastable ion fragmentation processes, consecutive fragmentations in different field free regions, charge exchange mass spectra, charge stripping mass spectra, doubly charged ion mass spectra, chemical ionization mass spectra, negative ion mass spectra, negative ion mass analysed ion kinetic energy spectra, negative ion mass analysed ion kinetic energy collision induced dissociation spectra, charge inversion spectra, etc. The complementary types of information available from the above studies are discussed to show the unique versatility of mass spectrometry as a technique for the examination of organic compounds.
    Additional Material: 32 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 19 (1984), S. 199-199 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1981), S. 312-322 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Consecutive reactions involving the ejection of molecules of carbon monoxide from quinone systems have been studied. Using a reversed geometry double focusing mass spectrometer, the individual steps of a consecutive reaction may be separated into different field free regions. The structure of ions formed in the ion source may be compared with those formed from the fragmentation of metastable ions in a field free region by studying differences in the pattern of translational energies released when they break. In the case of anthraquinone it is found that two structures exist for the [M—CO]+· ion. Critical energy measurements strengthen this argument. Furthermore, 18O labelling has been used to distinguish between the loss of carbon monoxide from different positions on the molecular ion of 1-hydroxyanthraquinone.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1980), S. 564-567 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Characterization and assignment of the products of metastable decompositions which are transmitted by a double focusing mass spectrometer, is often complicated by the inability to measure precisely the parent/daughter ion mass values directly from the spectra which appear on chart paper. This is often because there are considerably fewer peaks in these types of spectra compared with a normal mass spectrum obtained from high energy reactions in the ion source. Electronic circuits are described which permit accurate parent/daughter ion mass values to be obtained when the products of metastable decompositions are transmitted through the ZAB-2F double focusing mass spectrometer. Digital logic circuitry is also described which is used to mark mass values during a scan by driving either a solenoid pen drive unit for a chart recorder or a galvanometer on a multi-range ultraviolet oscillograph recorder.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...