ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (1,202)
  • Analytical Chemistry and Spectroscopy  (1,111)
  • Industrial Chemistry
  • 1980-1984  (1,029)
  • 1965-1969  (169)
  • 1945-1949  (4)
Collection
  • Articles  (1,202)
Publisher
Years
Year
  • 1
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 371-374 
    ISSN: 0935-6304
    Keywords: Free radical crosslinking ; Capillary gas chromatography ; Azo compounds ; Nonextractable Polysiloxane stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: There has been much effort spent in recent years developing the technology for free radical crosslinking of polysiloxane polymers to prepare capillary columns coated with thermally stable and nonextractable stationary phases. Organic peroxides have been used extensively as the free radical initiators for the in situ polymerization of the stationary phases. However, these peroxides adversely affect the phase polarity and column activity. Seven azo compounds were studied for crosslinking efficiency. Azo compounds can be used as free radical initiators to prepare nonextractable stationary phases without the adverse effects caused by peroxides.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Three basic hexapeptides which have two adjacent arginyl residues were studied by field desorption mass spectrometry. At low emitter temperature singly and doubly charged pseudomolecular ions [M + 1]+ and [M + 2]2+ were observed. At higher temperature, these peptides gave a relatively complex fragmentation pattern which can be explained as resulting from preferential cleavages involving the Arg-Arg sequence. A mechanistic interpretation is proposed for this type of fragmentation.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 11 (1984), S. 535-538 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: It is shown that a fast evaluation of field desorption mass spectrometric profiles can be obtained, using quotient spectra and calculation of quotient weight factors. The characteristics of a program developed for this purpose are described and as an example this approach has been applied to detect metabolites in urine samples.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 21 (1983), S. 555-563 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The 1H NMR chemical shifts and the spin-spin coupling constants of the non-exchangeable protons of the N-terminal 13-residue C-peptide of ribonuclease A, obtained by cleavage of the enzyme with cyanogen bromide, have been measured in a 5 mM solution in D2O (pH 3.0, 24°C) at 360 MHz. The titration parameters for end groups (Lys-1 and homo-Ser-13) and side chains (Lys-1, Glu-2, Lys-7, Glu-9 and His-12) have been determined. The chemical shifts, their temperature coefficients and the vicinal coupling constants, 3J(HNCH-α), for the exchangeable NH protons have been measured in a 5 mM solution in D2O/H2O (1:9 v/v) at pH 3.0. An assignment of observed signals to individual residue protons based on characteristic shifts, standard double resonance experiments, spectral simulations and titration shifts is proposed. All experimental evidence indicates that under the conditions studied the C-peptide is in a random coil form.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 19 (1982), S. 63-65 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The eight spin NMR spectrum (400 MHz) of bicyclopropylidene oriented in a nematic phase has been analysed. The absolute signs and values of 5J(HH) long-range spin-spin coupling constants have been determined for the first time for this molecule. The ratios of interatomic H—H distances have been deduced from the direct coupling constants.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 400-404 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; Thin-layer chromatography, TLC ; Amniotic fluid ; Fetal lung maturity ; Phospholipids ; Lecithin/Sphingomyelin ratio, L/S ; Shake test ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the HPLC separation of phosphatidylglycerol (PG), phosphatidylinositol (PI), phosphatidylcholine (PC), and sphingomyelin (SPH) was achieved using five in-series columns packed with LiChrosorb, Partisil, and μ-Porasil adsorbents, a solvent mixture of chloroform/methanol/ammonium hydroxide (50 : 36 : 6.7, by volume), and a Pye LCM2 Moving Wire (FID) detector. The same phospholipid mixture was also separated using four μ-Porasil columns with the same eluent and detector. The latter conditions were found to be suitable for the analysis of phospholipids obtained after centrifuging, extraction, and precipitation of surface-active lipid components of patient amniotic fluid collected at amniocentesis section. The lecithin/sphingomyelin (L/S) ratios, determined by the HPLC method, correlated well with those determined by the TLC technique in four normal pregnancies, whereas results of shake tests did not correlate too well with L/S ratios determined by the above two chromatographic methods. Besides the lecithin/sphingomyelin ratio, the present method was able to supply additional information: the concentrations of phosphatidylglycerol and phosphatidylinositol, for prediction of fetal lung maturity, and the palmitic acid content of amniotic fluid phosphatidylcholine.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 574-576 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Extraction ; Liquid-liquid ; Low-volume ; THM's ; Water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 605-611 
    ISSN: 0935-6304
    Keywords: High resolution chromatography ; Marine hydrocarbons ; Biota samples ; Organochlorinated compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Analyses of hydrocarbon fractions from different areas of the marine environment are described to illustrate the possibilities and limitations of high resolution gas chromatography (HRGC) in the analysis of environmental samples. Examples are given of dissolved, particulate, and sedimentary hydrocarbons and organochlorine compounds; the importance of an adequate sampling of the marine environment is stressed. HR chromatographic profiles obtained in two columns of low and high polarity (SE-52 and PEG 20M) permit the sources and transport pathways of both natural and anthropogenic hydrocarbons to be traced. Analysis of tissues of marine mammals, which metabolize or excrete many of the biogenic and petrogenic hydrocarbons present in other areas of the marine environment, may provide an opportunity to obtain relatively clean profiles of many anthropogenic compounds of interest. The plotting of mass chromatograms from data compiled by COM-GC-MS remains the most appropriate method for the conclusive indentification of these compounds.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 13-18 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Biphenyl polysiloxane ; Stationary phase ; Polarizable phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A crosslinkable biphenylmethylpolysiloxane stationary phase was synthesized for capillary column gas chromatography and compared with methyl, phenyl, and cyanopropyl polysiloxane stationary phases for the separation of isomeric polycyclic aromatic compounds. While the new phase gave similar separations of nonpolar isomers when compared to the nonpolar phases, separations of polar isomers were greatly improved because of the induced polarity of the biphenyl group of the stationary phase by the solute molecules. This polarizable stationary phase offers a unique selectivity which is not available in other stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...