ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Bone  (29)
  • hypertension  (26)
  • oxidation  (24)
  • Springer  (79)
  • Annual Reviews
  • Oxford University Press
  • 1980-1984  (48)
  • 1975-1979  (31)
Collection
Keywords
Publisher
  • Springer  (79)
  • Annual Reviews
  • Oxford University Press
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 369-374 
    ISSN: 1432-0827
    Keywords: Histomorphometry ; Bone ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary To study bone histomorphometry reproducibility in normal subjects, we performed during orthopedic surgery bone biopsies in 16 post-menopausal women. Each woman had four bone biopsies, two at the usual site in the iliac crest, one on the left and one on the right side, and two other biopsies just behind the usual site, one at each side. We performed measurements of trabecular bone volume, relative osteoid volume, osteoid surfaces, osteoclastic resorption surfaces and calcification front. The average values of the 16 patients were compared, on the one hand, two by two, by a student test, and on the other hand, by a variance analysis. By these two methods the results showed no significant difference between the average values of the 16 patients at each location for any of the histomorphometric parameters studied. However, there was a location variation which was estimated by the intra-individual variation for a given patient. On the other hand, we calculated from the variance analysis the location variance for a group of 10 to 100 patients. In any case all the parameters had a location variation which was high for osteoclastic resorption surfaces and relative osteoid volume when expressed in % of the absolute value of these parameters. The variation of the trabecular bone volume was 0–46. 15% (95% confident limit interval) in a single patient and the hypothetical value of the location variation was 41.6% for a group of 10 patients and 13.0% for a group of 100 patients.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 12 (1977), S. 171-174 
    ISSN: 1432-1041
    Keywords: Tolamolol ; hypertension ; pharmacokinetics ; mean steady-state concentration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Tolamolol was administered in a “double-blind” study to fifteen hypertensive patients by dose-titration against arterial blood pressure. Mean steady-state plasma tolamolol concentrations (Css) were determined for each patient from the area under the plasma concentration — time curve during a dosage interval whilst patients were receiving optimal tolamolol doses. No significant correlation was observed between daily tolamolol dose and Css; the relationship between fall in lying mean arterial pressure and Css also failed to reach conventional levels of statistical significance, but Css was observed to be correlated with the fall in standing pressure. The results suggest that plasma concentrations in excess of 200 ng/ml may be required to achieve an effective hypotensive response with the drug.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 27 (1984), S. 397-405 
    ISSN: 1432-1041
    Keywords: indapamide ; hypertension ; cardiovascular reflexes ; diuretic effect ; blood pressure variability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Nine elderly and 11 young hypertensives underwent continuous ambulatory monitoring of blood pressure (BP), assessment of cardiovascular reflexes and M-mode echocardiography as hospital in-patients prior to treatment with once-daily indapamide (2.5 mg). They were followed as out-patients for 4 months during which time casual BP was measured at monthly intervals. The patients were then readmitted to hospital and studied using the same protocol under similar standardised conditions. The results showed that indapamide reduced casual and ambulatory BP in both young and elderly although the most marked effect was seen on systolic BP. Assessment of cardiovascular reflexes indicates that at least part of the hypotensive action of indapamide is due to a diuretic effect. Treatment with indapamide has comparable results on both young and elderly.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1041
    Keywords: Tolamolol ; methyldopa ; comparative trial ; hypertension ; beta-blockade
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The efficacy and toxicity of tolamolol and methyldopa in hypertensive patients has been compared by a dose-titrated, double-blind, cross-over study. Thirteen patients completed the trial. Within the dose ranges investigated (tolamolol — 300 mg/day — 900 mg/day; methyldopa — 750 mg/day — 2250 mg/day) both drugs produced significant falls in laying and standing, systolic and diastolic blood pressures. Although the hypotensive effects of methyldopa were more marked than tolamolol, these only achieved conventional (P〈0.05) levels of significance for lying blood pressure. There were no objective changes in haematological or biochemical indices during treatment with either drug, but patients complained of tiredness, weak limbs and mouth dryness significantly more during methyldopa treatment, than during either placebo or tolamolol therapy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Oxidation of metals 14 (1980), S. 263-277 
    ISSN: 1573-4889
    Keywords: oxidation ; Ni-Cr alloys ; two-phase alloys
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Oxidation of the relatively simple, two-phase alloy Ni-70 wt.%Cr in oxygen between 1073 and 1473°K results in the formation of a Cr2O3 scale containing less than O.5 wt.% Ni in solid solution. The oxidation kinetics are irreproducible for an initial period, which is brief at 1073 and 1273°K but much more pronounced at 1473°K, both in duration and degree. This behavior is associated with the failure of the protective Cr2O3 scale. However, after longer periods a compact layer of Cr2O3 becomes established under isothermal conditions and results in a change to more reproducible kinetics, especially at 1073 and 1273°K. Oxidation causes chromium depletion and the formation of a single-phase zone which separates the scale and the two-phase bulk alloy. The depth of Cr2O3 internal oxide coincides with this zone. The oxidation behavior is compared with that of more Ni-rich, single-phase Ni-Cr alloys, with particular reference to the effects of the constitution of the underlying alloy and the integrity of the protective oxide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Oxidation of metals 18 (1982), S. 295-314 
    ISSN: 1573-4889
    Keywords: Nickel-manganese alloys ; oxidation ; solid solution scales ; internal oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Ni-Mn alloys containing up to 38% Mn have been oxidized in pure oxygen between 873 and 1273 K and the parabolic rate constants measured. The scale morphologies and oxide compositions are interpreted in terms of modifications to the scale on pure Mn caused by the presence of Ni. The scales are composed predominantly of two layers at all temperatures, giving the sequences of phases alloy/cubic monoxide (Ni, Mn)O/ternary spinel, with the cubic (Ni, Mn)O layer always having the greater thickness. There is limited evidence for a third, very thin, outer layer in the scales on all alloys at 873 K and for Ni-38%Mn at 1073 K, which is tentatively considered to be Mn2O3, giving layers in the order alloy/cubic monoxide/ternary spinel/Mn2O3, by analogy with the scale formed on pure Mn. The distribution of the alloy components in the scale is discussed in relation to the Ni-Mn-O phase diagram and in terms of recent theoretical treatments of solid solution scale formation on binary alloys, as far as the available diffusion data allow. The occurrence of internal and intergranular oxidation and the formation of a Mn-depleted zone coincident with the band of uniform internal oxide are considered briefly.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Oxidation of metals 9 (1975), S. 215-223 
    ISSN: 1573-4889
    Keywords: cation diffusion ; oxidation ; metal partition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract An alternative mass balance at the alloy-scale interface is proposed for the Wagner theory of binary alloy oxidation. A simple relation between the bulk composition of the alloy and the scale composition at the alloy-scale interface, ξ′, is derived in terms of the transport properties of the scale and the limit of application of the relation defined. There is good agreement between calculated and measured values of ξ′.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Oxidation of metals 12 (1978), S. 247-256 
    ISSN: 1573-4889
    Keywords: oxidation ; iron ; magnetite ; oxide thickness ; electron back-scattering Mössbauer spectroscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Magnetite films in the range 265–4520 Å have been grown on natural iron substrates and subsequently investigated by electron back-scattering Mössbauer spectroscopy. In particular, the percentage, P, of the total spectrum area contributed by the oxide has been determined as a function of oxide thickness, d. It was found that d up to ≈ 3000Å may be expressed (to an accuracy of ∼ 5%) by d (Å)=−1.95 × 103 ln (1–0.01 P). The experimental data have been compared with the theoretical predictions of both Huffman and Bainbridge. Good agreement between experiment and Huffman's predictions of P is obtained using values of the electron attenuation coefficient, μ, of 1.10 × 104 cm2 g−1 for the 7.3 keV electrons and 1.73 × 104 cm2 g−1 for the 5.4 keV electrons. A good fit of our data to Bainbridge's expression requires a somewhat lower effective μ, value of 0.8 × 104 cm2 g−1. The experimental P value for the thickest oxide (4520 Å) is lower than the theoretical predictions, probably as a result of a neglected mechanism recently identified by Tricker, Ash, and Cranshaw.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Oxidation of metals 13 (1979), S. 437-456 
    ISSN: 1573-4889
    Keywords: Fe-Cr ; oxidation ; kinetics ; oxide morphology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Ferritic polycrystalline Fe-24 wt.% Cr was oxidized in pure oxygen at 190 ≤ T≤490° C and pressures in the range 5.3×10−2–13.3 Pa for periods of up to 5 hr. The reaction proceeded in three stages. An initial period of accelerating rate was accompanied by oxide island nucleation and growth. Following island coalescence the rate was approximately logarithmic at low temperatures and somewhat slower than parabolic at high temperatures. Rate control during this period was thought to be due to mass transport through the oxide grain boundaries left by the island impingement process. During these first two stages the oxide formed was γ-M2O3 with possibly some spinel. The final stage of reaction involved the appearance of α-M2O3 on the outer oxide surface and a substantial slowing of the oxidation rate due to the low diffusivity in this phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 283-289 
    ISSN: 1432-0827
    Keywords: Bone ; Resorption ; Osteoclast ; Quantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The stimulation of bone resorption, assessed by the release of45Ca from prelabeled bones, was associated with an increase in number of osteoclasts per bone section in parathyroid hormone (PTH)-treated bones, but not in lipopolysaccharide (LPS)-treated bones. By contrast the number of nuclei per osteoclast increased following LPS treatment, but was not affected by PTH. LPS-treated bones had more multinucleated cells, some having as many as 27 nuclei per osteoclast. More osteoclasts were adjacent to the bone collar in bones treated with LPS or PTH than in control bones. In LPS-treated bones this area also contained the largest osteoclasts, as determined by the greatest number of nuclei per osteoclast. The results suggest that LPS and PTH stimulate osteoclastic resorption by different mechanisms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...