ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Polymer and Materials Science  (2.117)
  • Organic Chemistry  (298)
  • Wiley-Blackwell  (2.415)
  • Springer
  • 1980-1984  (1.376)
  • 1975-1979  (1.031)
  • 1905-1909  (8)
Sammlung
Verlag/Herausgeber
  • Wiley-Blackwell  (2.415)
  • Springer
Erscheinungszeitraum
Jahr
  • 1
    ISSN: 0018-019X
    Schlagwort(e): Chemistry ; Organic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Pure pencillin N α-sulfoxide (1) and penicillin N β-sulfoxide (2) were obtained by HPLC and tested as substrates for deacetoxycephalosporin C synthetase (DXCS). Neither one of the sulfoxides was utilized under conditions of conversion of penicillin N (8) to deacetoxycephalosporin C (9). The cephalosporin C α and β-sulfoxides (3 and 4, resp.) were also prepared. Relative stabilities of the sulfoxides 3 and 4 are discussed by interpretation of the 13C-NMR spectra.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0021-8383
    Schlagwort(e): Chemistry ; Organic Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Studies on Sulphochlorination of Paraffins. V. Kinetic Studies on the Sulphochlorination of Pure AlkanesulphochloridesThe mixtures of disulphochlorides formed by sulphochlorination of 1-alkanesulphochlorides C4—C9 may be analyzed gaschromatographically after transformation into the corresponding dimethylamides. The individual peaks could be identified in some cases with the aid of pure isomeric disulphochlorides, in other cases they were identified by analogy. The mixtures formed by sulphochlorination of the isomeric heptane sulphochlorides also could be analyzed after transformation into the dimethylamides; the identification of all peaks was possible by comparison of the mixtures obtained from different heptane sulphochlorides.For the alkane sulphochlorides studied the relative rates of sulphochlorination (with reference to n-octane) were determined, and therefore the relative reaction rates of the individual C—H-bonds with reference to one primary C—H-bond of n-octane could be calculated.The results show a geminal or vicinal disubstitution not to take place in noticeable amount. In position 3 or in greater distance the influence of the sulphochloride group on the reactivity of the C—H-bonds is not significant.
    Zusätzliches Material: 7 Tab.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 509-519 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The deterioration of polyolefin, poly(ethylene terephthalate), and polyamide films under soil burial conditions extending up to 32 months has been investigated. Based on changes in their elongation at break, the films can be ranked in order of increasing sensitivity to degradation: Polyester ≃ polypropylene 〈 low-density polyethylene ≃ high-density polyethylene 〈 nylon 6.6. The degraded nylon 6.6 and polyethylene films were characterized by infrared and luminescence spectroscopy and scanning electron microscopy, as well as by wet analysis for hydroperoxides. From a comparison with the well-known oxidative sensitivity of nylon 6.6 in oxygenated water at slightly elevated temperatures, the rapid deterioration of nylon 6.6 film during soil burial was also concluded to be an oxidative process. The somewhat smaller, but significant, embrittlement of the polyethylenes studied could not be simply explained by thermal oxidation (with only trace oxidation products detectable) or microbiological attack (deterioration being unaffected by surface activation to enhance wettability).
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 22 (1978), S. 2217-2228 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The destruction of various UV stabilizers in polypropylene films during irradiation has been examined both in the presence and absence of air and oxidation products. Although some stabilizers were destroyed in the absence of oxygen, all were more sensitive when irradiated in the presence of air. Several stabilizers were highly effective but were destroyed so rapidly that photoprotection of the polymer must have resulted from stabilizer products. Work with preoxidized polymer and with model hydroperoxides and peroxides indicated that most stabilizers were destroyed by the attack of oxygen-centered radicals, with peroxy radical attack appearing to dominate.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: A D2-m-dodecacarboranesiloxane containing alternating block copolymer \documentclass{article}\pagestyle{empty}\begin{document}$\rlap{--}[{\rm A}\hbox{---}{\rm B}\rlap{--}]_n$\end{document} was prepared by the reaction of a ureidosilane-terminated polysulfone hard block with a carboranesilanol-terminated carboranesiloxane oligomer. The resulting block copolymer exhibited thermoplastic elastomeric behavior. This unique polymer had excellent thermal stability up to 400°C.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 59-70 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Porous high-density polyethylene specimens were implanted in the femurs of mongrel canines. At the end of the residency period (3 or 6 months), the animals were sacrificed and the implants were retrieved. The work-of-fracture of the implant specimens was then determined using the technique of Tattersall and Tappin. The work required to fracture a specimen in three-point bending by controlled crack propagation through a triangular cross section was obtained directly from the load-deflection curve. The area of the resulting fracture surface was measured by macro-photographic techniques, and the work-of-fracture was calculated as work per unit area. The implants were subsequently sectioned and examined microradiographically to determine the extent of bone ingrowth. Bone specimens adjacent to the implants and porous high-density polyethylene controls (no ingrowth) were also tested to determine their work-of-fracture. The results showed that bone adjacent to the implant specimens had a higher work-of-fracture than normal medial, canine femoral bone and was not appreciably different from the composite. The work-of-fracture of porous high-density polyethylene was not significantly increased by an increase in bone infiltration, and this anomalous behavior was attributed to a degradation of the polyethylene during implant residence. Control studies supported this hypothesis.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 489-502 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Physical and in vivo (burned rat model) evaluations as wound coverings were performed for 1) a freeze-dried collagen/poly (∊-caprolactone) (PCL) film laminate, 2) a freeze-dried PCL “foam”/PCL film laminate, and 3) a heat-dried collagen/PCL film laminate. Porcine skin and cadaver skin were also evalulated in vivo for the purpose of comparison. Water-vapor transmission rates and Young's moduli were measured. The degrees of adherence of the coverings to the wound were measured. Grafts which became significantly adherent (〉150 dyne/cm2) to the wound within 1 day were most successful in promoting the formation of a viable tissue bed which appeared ready to accept further grafting. The force required to remove the PCL foam laminate from a full-thickness excision wound was found to increase from 170 dyne/cm2 on the first day postgraft to 1500 dyne/cm2 by the tenth day. The force required to remove freeze-dried collagen laminate remained constant at 200 dyne/cm2 over the 10 day test period. For the heat-dried collagen laminate, a force of only 50 dyne/cm2 was required on day 1, increasing to 200 dyne/cm2 on day 6. Insensible water-loss rates of animals grafted with the laminates were found to be similar to those from animals with human cadaver skin grafts and less than that from animals with porcine skin grafts. When moistened, the laminates prepared using the freeze-dried materials were flexible and somewhat transparent permitting observation of the wound.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 13 (1979), S. 765-782 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Kinetic and equilibrium studies of blood platelet binding to copolypeptide films show that attachment and serotonin release are not dependent upon the composition of the copolypeptide. Data may be explained by postulating that platelets frequently collide elastically with the surface but leave behind material that modifies subsequent behavior. Similarly, material released from platelets adsorbs at the interface and the extent of attachment and serotonin release are modified and controlled by these adsorbed species. Basically, if the platelet is exposed to a clean surface, its collision with the surface leads to activation and release. In the presence of inert protein, the collision is cushioned by the protein and platelets do not attach or release to any extent. Finally, if protein (or other entities) released from the platelet provide attachment sites, than attachment occurs without release. It is postulated that the behavior of platelets at surfaces is controlled by these interrelated processes.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 0142-2421
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: The provision of accurate composition-depth profiles to depths 〉 1 μm is important in the characterization and investigation of thick films, surface coatings, surface treatments and many other technologically important applications. At present, such profiles are usually achieved by sequential ion bombardment and surface analysis and hence involve many difficulties in interpretation due to the non-uniform erosion of surfaces under ion bombardment. In this paper a method of obtaining accurate depth profiles is described using a ball-cratering device. The method employs a rotating ball to fashion a well-defined spherical crater in the sample surface, the depth and width of which can be accurately controlled. The specimen is then cleaned in situ using a scanning ion beam for a short period and the composition-depth profile is obtained either by point-by-point analysis down the sloping sides of the crater wall or by using Auger line-scan techniques across the crater. Coating-substrate interface analysis can also be obtained by sputter-depth profiling at a point on the coating close to the exposed substrate. The method is not only considerably faster than ion etching, but the resulting depth profile also has a well-defined depth resolution. Composition-depth profiles through nitrocarburized mild steel surfaces and protective surface coatings are presented to illustrate the usefulness of the technique.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...