ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Breast volume  (1)
  • Solid-State Physics  (1)
  • Evolutionarily stable strategies
  • Population dynamics modeling
  • 1985-1989  (2)
Collection
Publisher
Years
Year
  • 1
    ISSN: 1573-9686
    Keywords: Stereophotogrammetry ; Validity ; Reliability ; Breast volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract A measurement technique has been developed for application in the area of noninvasive breast cancer detection. The measurement process involves the use of closerange stereophotogrammetry as a data acquisition device necessary for determination of breast volume and volume distribution. This report details the methodology used to acquire and analyze stereopair photographs necessary to document the validity and reliability of this application. The volume of a test object was determined by both water displacement and stereophotogrammetric analysis to estimate the precision of the proposed methodology. Additionally, the reliability component of the study was documented by analyzing variability of coordinates representing a series of locations marked on the surface of an irregularly shaped object. Both tests confirm that this stereometric analysis is a reliable and valid method of measurement and may be well suited for further development in the field of breast cancer detection.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-08-15
    Description: A method of zone refining a crystal wafer (116 FIG. 1) comprising the steps of focusing a laser beam to a small spot (120) of selectable size on the surface of the crystal wafer (116) to melt a spot on the crystal wafer, scanning the small laser beam spot back and forth across the surface of the crystal wafer (116) at a constant velocity, and moving the scanning laser beam across a predetermined zone of the surface of the crystal wafer (116) in a direction normal to the laser beam scanning direction and at a selectible velocity to melt and refine the entire crystal wafer (116).
    Keywords: Solid-State Physics
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...