ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 321-327 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Increasingly widespread usage of stable isotope tracers to aid clinical diagnosis and support basic research has stemmed from both advances in mass spectrometry and the availability of competitively priced labelled compounds. Stable isotopes have been used generally to investigate normal and abnormal metabolic pathways, to estimate energy expenditure and body composition and to quantitate substrate flux and oxidation rates. Despite the fact that the underlying principles relating to the use of stable isotopes for in vivo studies are straightforward, careful consideration must be given to all aspects of human studies. This review highlights some of these, including choice of label and tracer molecule, mode of tracer administration and sampling site, analytical instrumentation, interpretation of data and ethical constraints.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Electron capture detection ; Octachlorobenzo-p-dioxin ; Heptachlorobenzo-p-dioxin ; Polychlorinated dibenzofurans ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the analysis of contaminated building dust samples and surface swab samples for octachlorodibenzo-p-dioxin (OCDD) and heptachlorodibenzo-p-dioxins (HpCDDs). The samples were analyzed by fused silica capillary GC combined with electron capture detection. Analysis was preceded by a short HPLC cleanup step designed to remove polychlorinated biphenyls (PCBs) and other compounds that might interfere. The method was found to work successfully on surface swab and dust samples known to contain PCBs, OCDD, and HpCDDs. The overall recovery of the analysis procedure for OCDD was found to be approximately 80%. The detection limit for the method was sample dependent, but for one typical set of surface swab samples was 0.2 μg/m2 of OCDD.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 613-616 
    ISSN: 0935-6304
    Keywords: Gas chromatography, capillary, glass ; 5 mikrometer quartz powder roughening layer fused onto boro silicate glass during drawing process ; Complete procedure given reproducible preparation of stable thick film capillaries ; Static impregnation with 1.5% (w/v) rubber solutions possible ; Very low column bleed, ideal for GC-MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detailed method for the routine preparation of glass capillary columns is presented. The method consists of coating a glass tube with quartz powder prior to pulling the tube into a capillary. The inner surface of the capillary consists of an even distribution of quartz particles fused to the walls. This surface has been found readily deactivated by standard procedures and ideal for the preparation of thick-film glass capillary columns. The method has been thoroughly tested in two independent laboratories to ensure that the procedures described are reproducible.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 432-434 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary columns ; Radiation induced polymerization ; Crosslinking ; Immobilized phases ; Column activity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 759-764 
    ISSN: 0935-6304
    Keywords: Supercrirtical fluid extraction (SFE) ; Modified carbon dioxide in SFE ; Liquid trapping ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A polarity test mix consisting of acetophenone, N,N-dimethylaniline, naphthalene, 2-naphthol, and n-tetracosane was spiked onto sand and extracted with carbon dioxide modified with acetonitrile, methanol, or toluene. The extracts were collected in chloroform, hexane, methanol, or a mixed collection solvent consisting of equal parts chloroform-hexane-methanol. The mixed collection solvent which showed excellent recoveries for pure CO2, had the worst recoveries of all the collection solvents with modified CO2. Overall hexane was the best collection solvent studied for these analytes under these extraction conditions.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 361-365 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Electronic pressure control ; Pressure programming ; Constant flow ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary gas chromatographic separations were performed with an electronic pressure control system developed to provide precise closed-loop control of inlet pressure through the use of a solid state micro-machined pressure sensor and electronically controlled proportional valve. The closed-loop control of the electronic system provided better precision than the open-loop control achieved by manual pressure regulation. Closed-loop control can perform pressure programming, which can be combined with temperature programming to optimize separations. The pressure sensor monitors the integrity of the flow system and singals the controller to reduce flow in the presence of a sudden loss of system pressure.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 713-716 
    ISSN: 0935-6304
    Keywords: SFE ; Supercritical carbon dioxide ; Sand ; Test mixture ; Solvent trapping ; Solvent mixtures ; Trapping efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A polarity test mix consisting of acetophenone, N, N-dimethylaniline, naphthalene, decanoic acid, 2-naphthol, and n-tetracosane was spiked onto sand, and extracted with supercritical carbon dioxide, to evaluate the collection efficiency of various solvents and solvent mixtures. Nine single collection solvent systems and four mixed collection solvent systems were studied. When one-component collection solvents were employed, quantitative (above 90%) recovery of all analytes was not possible. With mixed collection solvents, recoveries of 90% or better with all analytes studied were possible.
    Additional Material: 4 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 649-655 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Splitless injection ; Electronic pressure programming ; Reduction in discrimination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An experimental injection port has been designed for split or splitless sample introduction in capillary gas chromatography; the inlet uses electronic pressure control, in order that the column head pressure may be set from the GC keyboard, and the inlet may be used in the constant flow or constant pressure modes. Alternatively, the column head pressure may be programmed up or down during a GC run in a manner analogous to even temperature programming. Using electronic pressure control, a method was developed which used high column head pressures (high column flow rates) at the time of injection, followed by rapid reduction of the pressure to that required for optimum GC separation. In this way, high flow rates could be used at the time of splitless injection to reduce sample discrimination, while lower flow rates could be used for the separation. Using this method, up to 5 μl of a test sample could be injected in the splitless mode with no discrimination; in another experiment, 2.3 times as much sample was introduced into the column by using electronic pressure programming. Some GC peak broadening was observed in the first experiment.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 91-91 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating technique details ; End-sealing without failure, under ethanol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1040-7685
    Keywords: fumonisin B1 ; mycotoxin ; Fusarium moniliforme ; FMOC derivative ; capillary electrophoresis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method has been developed for the analysis of fumonisin B1 in corn using capillary electrophoresis. Fumonisin B1 is the major fumonisin metabolite produced by the fungus Fusarium moniliforme and has been implicated in human and animal diseases. Fumonisin B1 was extracted from corn with acetonitrile/water (50/50) and cleaned up with a Waters C18 Sep-Pak Vac cartridge. Fumonisin B1 was quantitated after elution from the C18 Sep-Pak column using capillary electrophoresis (CE) with a 25 mM sodium borate buffer (pH 9.0) containing 10% acetonitrile and fluorescence detection of the FMOC derivative. The minimum detectable amount in corn was 0.5 ppm. Recovery values in spiked corn averaged over 96% over the range 1-20 ppm. © 1995 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...