ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 6 (1994), S. 115-125 
    ISSN: 1040-7685
    Keywords: gas chromatography ; stationary phases ; liquid crystal polysiloxane ; C18 polysiloxane ; shape selectivity ; polycyclic aromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Column selectivity is examined for a series of smectic liquid crystalline columns and is compared with methyl and C18 polysiloxane columns for the separation of polycyclic aromatic hydrocarbon (PAH) isomers. A set of extended and condensed solute probes is described that provides a sensitive indication of variations in column shape selectivity. Examples of shape selectivity differences are presented for smectic liquid crystalline columns and 5% phenyl polysiloxane columns using various PAH isomer sets. Variations in selectivity have been observed among different smectic liquid crystalline columns, and this problem appears more significant than for methyl polysiloxane columns. The selectivity ration for tetraphenylmethane and p-terphenyl provides a sensitive indication of column shape selectivity, with a change in elution order occurring between ordered (smectic liquid crystalline) columns and non-ordered (methyl polysiloxane) columns. Shape selectivity differences indicated by this test mixture are apparent for more complex PAH isomer mixtures. Despite stationary phase selectivity variability, smectic liquid crystalline columns offer considerable potential for solving difficult separation problems involving structured solutes.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 953-956 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A mixture of four squalestatins was separated anil characterized by gradient packed capillary liquid chromatography combined with electrospray collision-induced dissociation mass spectrometry (ESI/CID/MS). Negative-ion ESI was found to afford spectra typified by strong pseudo-molecular ions but providing little structural information. Structural information was obtained using an ion-focusing RF-only octapole lens to provide conditions for CID. The new method showed improvements in sensitivity when compared to existing thermospray and dynamic liquid secondary-ion mass spectrometry methods.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Molecular Reproduction and Development 36 (1993), S. 313-319 
    ISSN: 1040-452X
    Keywords: Carbohydrate metabolism ; Aerobic glycolysis ; Amino acids ; Viability ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: The uptake of pyruvate and glucose by individual sheep oocytes and preattachment sheep embryos at each state of development up to the hatching blastocyst was determined using a microfluorescence technique. After an initial increase at fertilization, pyruvate uptake was relatively constant (˜15 pmol/embryo/h) from the zygote through to the morula. Upon blastocyst formation and hatching, there were significant increases in uptake (39 pmol/embryo/h, P 〈 0.001; and 53 pmol/embryo/h, P 〈 0.001, respectively). In contrast to that of pyruvate, glucose uptake was very low (˜1 pmol/embryo/h) up to the time of genome activation (eight- to 16 cell stage), after which there were significant increases in uptake at each successive stage of development. By the hatching blastocyst stage, glucose uptake had reached 54 pmol/embryo/h. The ability of day-7 hatching blastocysts to oxidize pyruvate and glucose was determined indirectly by measuring the production of lactate when either substrate was present as the sole energy source. Unlike the mouse blastocyst, which has a considerable oxidative capacity for both pyruvate and glucose, the day-7 sheep blastocyst showed limited ability to oxidise either substrate. Rather, in the sheep blastocyst, 65% of pyruvate and 98% of glucose taken up could be accounted for as lactate. Such low levels of substrate oxidation appear to be inconsistent with the energy requirements of the proliferating preattachment ruminant blastocyst. The utilization of alternative substrates at the blastocyst, such as amino acids, is proposed. © 1993 Wiley-Liss, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 1055-1058 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A System to automate the analysis of routine mass spectrometry samples, using either a thermospray or particle-beam interface, has been developed. This has allowed unattended operation and has freed expert mass spectrometrists to address ‘real’ problems. The system also acts as a filter to the problem-solving service.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 1059-1061 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The non-ionic surfactant Triton X-100, 1-(1,1,3,3,-tetramethylbutyl)-4-[poly(1,2-ethanediol)]benzene, has been evaluted as a reference material for positive-ion high-resolution ammonia chemical ionization (CI) mass spectrometry and as a tuning and calibration material for positive-ion thermospray mass spectrometry (TSP). When ammonia is used as the CI reagent gas, Triton-X-100 produces evenly spaced ions that 44 u apart. Triton X-100 cab be volatilized from a solids prove and is routinely used as the reference material for high-resolution measurements. A reference table has been constructed from the theoretical values for the different masses. Triton X-100-Reduced and Triton X-405-Reduced were also evaluated as additional reference com-pounds. As a calibration and tuning compound for TSP, Triton X-100 affords an envelope of ions centred around m/z 600-700 with ions observed above m/z 1000. Triton X-100-Reduced affords a similar envelope although the ions observed are 6 u higher in mass.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 492-495 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A mixture of four squalestatins was separated and characterized by gradient-packed capillary liquid chroma-tography combined with dynamic liquid secondary-ion mass spectrometry (LSIMS). Thioglycerol/glycerol matrix was added post-column. Negative-ion LSIMS was found to afford spectra typified by strong molecular ions with structurally informative fragments. The new method showed improvements in sensitivity and specificity for this class of compound when compared to existing thermospray methods.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, N.Y. : Wiley-Blackwell
    Journal of Cellular Biochemistry 53 (1993), S. 248-248 
    ISSN: 0730-2312
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: In human mammary carcinoma, positive immunohistochemical staining for p53 protein is not always indicative of mutation in the p53 gene. Although positive staining is seen in excess of 50% of tumours, mutations have been found in only some 20% of cases. In this presentation, positive p53 staining in mammary carcinomas will be related to the presence and absence of mutation and other possible underlying mechanisms.In some positively stained tumours a mutation has been found. In others, no mutation has been demonstrated and apart from possible stabilisation by a protein such as MDM2, there are alternative underlying mechanisms for this discrepancy. Wild type p53 is elevated in response to DNA damage. This effect can be seen in patients given pre-operative chemotherapy and in cell lines irradiated with UV light and with x-rays. Strong positive staining in scattered nuclei has been found in cell lines with activated ras and myc genes. We postulate that this may also be the reason for similar patterns observed in human tumours.Comparable mechanisms may be active in inherited cancers. Although positive p53 staining in some Li-Fraumeni syndrome patients is associated with mutation, in other Li-Fraumeni-like families, no mutation has been found despite positive staining in tumour and normal tissues.Whatever the mechanism underlying the stabilisation of the protein, increased expression of p53 protein in the majority of tumour cells appears to be associated with poor prognosis in breast carcinoma.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    BioEssays 15 (1993), S. 689-690 
    ISSN: 0265-9247
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...