ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (12)
  • 42.75
  • Verspreiding
  • 1990-1994  (12)
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Zone-electrophoretic sample treatment ; Basic and acidic compounds ; Biological samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A modified valve arrangement for zone-electrophoretic sample treatment (ZEST)-which is coupled on-line with column liquid chromatography — is used to pretreat biological (plasma) samples. Carry-over of plasma proteins depends on the pH of the electrophoresis buffer. The determination of propranolol, metoprolol, cromolyn and salicylic acid demonstrates that both basic and acidic analytes can be isolated from the plasma matrix with high selectivity. Analogous piperazines, with different protein binding properties, were used to study the influence of protein binding on the recovery. It is shown that high protein can cause a decreased recovery.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Sample treatment ; Zone electrophoresis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The design of a new valve arrangement for zone-electrophoretic sample treatment (ZEST) coupled online with high performance liquid chromatography is described. Characteristics of this valve, such as the internal heat development as a function of the current, have been investigated. By using quinidine and desipramine as model compounds it is shown that charged compounds can be isolated from biological samples, in about 15 min, with high selectivity. The carry-over of proteins to the analytical column has been compared with the carry-over using a pre-column sample clean-up method. The detection limits of quinidine and hydroquinidine (50 ng/ml), using zone-electrophoretic sample treatment coupled with column liquid chromatography, are in the same range as with direct injections using pre-columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; On-line coupling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An electrodialytic sample treatment method coupled on-line with high-performance liquid chromatography (EDIST-HPLC) is discussed in this paper. The performance of EDIST as a function of the donor-phase (sample solution) flow rate, the voltage applied over the electrodialysis block, and the time of dialysis has been studied using the basic drug ephedrine as a model compound. Enrichment of the analyte by a factor of 10–20 was possible. The determination of human plasma spiked with ephedrine is briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrodialytic sample treatment ; Computer models ; Analyte enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Basic considerations for analyte enrichment and recovery obtainable by electrodialysis as a sample treatment method are given. Equations are derived which describe the dependence of the concentration profiles of ionic compounds on the electric field strength in a set-up with stagnant donor and acceptor solutions. It is shown that analyte recovery increases when less ion-selective membranes are used in the electrodialysis cell. Computer models are used to estimate the analyte enrichment for a flowing donor (sample) and a stagnant acceptor phase. About 10-fold enrichment can be obtained in an electrodialytic sample treatment system within 20 min under maximum current conditions. A compromise has to be found between analyte recovery and the donor (sample) flow rate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Membrane-extraction disks ; On-line trace enrichment ; Polar pollutants ; Surface water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line trace-enrichment system, using a bifunctional membrane extraction-disk cartridge, has been combined with a column liquid chromatography separation for the simultaneous determination of basic, neutral and acidic pollutants in surface water. The enrichment device consisted of a specially constructed holder containing both C-18 and cation-exchange disks. The holder can contain up to 25 disks of 0.5 mm thickness and 4.6 mm diameter. Before trace enrichment of 20 ml of surface water (pH 3.0), calcium ions were removed from the sample by means of an oxalic acid precipitation. Desorption of the cartridge was at elevated temperature using reversed-phase gradient elution; detection was performed with a diode-array UV absorbance detector. The detection limits for the test compounds in surface water are typically 0.5–2 μg/l; the calibration graphs are linear from the lower limit of determination up to 50 μg/l.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Immunoaffinity precolomn ; Oestrogens ; Bioanalysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An automated liquid chromatographic system is described using immunoaffinity precolumns for sample pretreatment. The system consists of a column-switching unit allowing preconcentration from a large volume of sample (e.g. 15 ml of urine) onto an immunoaffinity precolumn (containing polyclonal antibodies immobilized on Sepharose). After sorption, the analytes are desorbed by a mixture of two cross-reacting solutes, followed by reconcentration on a C-18-bonded silica precolumn, and then separation on a C-18-bonded silica analytical column. Using oestrogen steroids as model compounds and UV absorbance detection, the minimum detectable concentration is ca. 200 ng/l with a repeatability of 6–8%. The total analysis time is 45 min which allows the unattended analysis of 30 samples per day. The features of the sample pretreatment method, especially of the immunoselective desorption, are evaluated and the general applicability of the system is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; On-line preconcentration ; Polar pollutants ; Water (tap and surface)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An isocratic column liquid chromatographic system with UV absorbance detection at 230 nm has been developed for the rapid trace-level determination of a large number of polar pollutants in water. The systems contains two precolumns, in series, which are packed with a styrenedivinylbenzene (PLRP-S) polymer. The second precolumn is also loaded with sodium dodecylsulphate before use. Each precolumn is combined with a PLRP-S analytical column, and aqueous acetonitrile mixtures (pH 3) are used for the separation of neutral as well as acidic and basic pollutants. With 10-ml water samples the detection limits for all analytes, in tap water, are in the low to sub μg/l range. Relevant analytical data are reported and the advantage of using a dodecylsulphate-loaded precolumn over a cation-exchange precolumn is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polar pollutants in water ; On-line trace enrichment ; Humic substances
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A practical liquid chromatographic early-warning system for polar pollutants in water ought to have detection limits at a level below a microgram per litre. Using ultraviolet absorbance detection this normally necessitates trace enrichment of the samples. In this study ten different sorbents have been tested with respect to their enrichment capacity. The hydrophobic polymeric PLRP-S material, in combination with a C-18 modified analytical column, proved to be the best choice. The influence of humic substances, present in surface water, was also studied. Lowering of the sample pH, resulted in a significant increase in the interferences due to the humic substances.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Particle beam interface-mass spectrometry ; Water analysis and identification of unknown ; pollutants ; Phenylurea herbicides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Trace enrichment on a precolumn packed with copolymer material, coupled on-line with reversed-phase, column liquid chromatography-particle beammass spectrometry (RPLC-PB-MS) has been used for both target and non-target analysis of water samples. RPLC is carried out on a C-18-bonded silica column using a linear acetonitrile-0.1 M ammonium acetate gradient. Using optimised PB-MS conditions and 100–250 ml water samples, the detection limits for several phenylureas are in the 0.03–0.05 μg l−1 range using the full-scan mode; repeatability is good and the LC-PB-MS system is robust. Several surface and drinking water samples have been analysed and low levels of various environmental contaminants have been identified using electron impact mass spectra. Applying chemical ionisation with methane as reagent gas in both the positive and negative mode in conjunction with PB-MS provides relevant confirmatory information.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gas chromatography-mass spectrometry ; Water analysis ; Triazine herbicides ; Chemical ionization mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Mass spectra of 12 triazines were obtained by electron impact (EI), positive-ion chemical ionization (PCI) and negative-ion chemical ionization (NCI) using methane and isobutane as reagent gases. EI mass spectrometry is more sensitive than PCI and NCI, although the chemical ionization modes increase selectivity markedly. A pre-column packed with polymer stationary phase was employed to preconcentrate surface and drinking water samples. After desorption of the analytes with ethyl acetate, an aliquot was injected directly into the GC-MS system. Atrazine and simizine were found in these samples at 10–80 ppt levels. The limits of detection for both herbicides were below 10 ppt in drinking water.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...