ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Second normal stress difference  (1)
  • first normalstress difference  (1)
  • 1990-1994  (2)
  • 1935-1939
Collection
Publisher
Years
  • 1990-1994  (2)
  • 1935-1939
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 29 (1990), S. 261-280 
    ISSN: 1435-1528
    Keywords: Relaxation ; first normalstress difference ; Gaussianerror function ; stress test ; cone and platerheometer ; mirror relation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Abstract By means of a cone and plate rheometer the relaxation of the shear stress and the first normal stress difference in polymer liquids upon cessation of a constant shear rate were examined. The experiments were conducted mostly in a high shear rate region of relevance for the processing of these materials. The relaxation behavior at these shear rates can only be measured accurately under extremely precise specifications of the rheometer. To determine under which conditions the integral normal thrust is a convenient measure for the relaxing local first normal stress difference the radial distribution of the pressure in the shear gap was measured. The shape of relaxation of both the shear stress and the first normal stress difference could be closely approximated for the entire measured shear rate and time range by a two parameter statistical function. In the range of measured shear rates, one of the parameters, the standard deviationS, is equal for the shear and the normal stress, and is independent of the shear rate within the limit of experimental error. The second parameter, the mean relaxation timet′ 50,τ of the shear stress andt′ 50,σ of the first normal stress difference, can be calculated approximately from the viscosity function and only a single relaxation experiment.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 31 (1992), S. 294-305 
    ISSN: 1435-1528
    Keywords: Second normal stress difference ; concentrated suspensions ; coneand-plate rheometer ; steady shear
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Abstract In the present work the measurement and description of the second normal stress difference in pure viscoelastic fluids and in suspensions of these fluids is discussed. The various measurement methods implemented to date are described briefly. Following this, the cone-and-plate distance method, which was introduced by Jackson and Kaye, is discussed. The analysis method of this experimentally relative simply implemented technique is modified. This is done by assuming that the ratio ψ* of the second normal stress difference to the first is independent of shear rate. This permits the precalculation of the measured function with ψ* as a curve parameter. The best possible fit of the measurement leads to the determination of ψ*. This method is used to measure the normal stress ratio of pure polyisobutene and of a 34.5% suspension of the same fluid. The result for the pure fluid matches literature values; ψ* of the suspension was found to have negative sign, as for the pure fluid, but to be of much greater magnitude.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...