ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • *Saccades  (1)
  • Lower-limb amputee  (1)
  • 1990-1994  (1)
  • 1980-1984  (1)
  • 1940-1944
  • 1
    facet.materialart.
    Unbekannt
    American Association for the Advancement of Science (AAAS)
    Publikationsdatum: 1983-09-16
    Beschreibung: The saccadic system accurately compensates for perturbations of eye position produced by microstimulation of the superior colliculus. This requires that information about the stimulation-induced change in eye position be provided by an extraretinal source--either proprioceptive endings in extraocular muscles or a centrally generated corollary discharge. It is shown that compensation remains intact after elimination of extraocular muscle proprioception, demonstrating that corollary discharge provides accurate eye position information.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Guthrie, B L -- Porter, J D -- Sparks, D L -- F32 EY05651/EY/NEI NIH HHS/ -- P30 EY03039/EY/NEI NIH HHS/ -- R01 EY01189/EY/NEI NIH HHS/ -- New York, N.Y. -- Science. 1983 Sep 16;221(4616):1193-5.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/6612334" target="_blank"〉PubMed〈/a〉
    Schlagwort(e): Animals ; *Eye Movements ; Macaca mulatta ; Oculomotor Muscles/*physiology ; Photic Stimulation ; Proprioception ; *Saccades ; Superior Colliculi/*physiology
    Print ISSN: 0036-8075
    Digitale ISSN: 1095-9203
    Thema: Biologie , Chemie und Pharmazie , Informatik , Medizin , Allgemeine Naturwissenschaft , Physik
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 30 (1992), S. 89-96 
    ISSN: 1741-0444
    Schlagwort(e): Lower-limb amputee ; Pressure ; Prosthetic interface ; Shear stress ; Transducer
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Although normal pressures at the stump socket interface of the lowerlimb amputee have been investigated, little is known about the shear stresses that also occur. Studies suggest that the combination of both shear and normal stresses significantly exacerbates discomfort and vascular and tissue damage. A means of simultaneously measuring normal and shear stresses will aid in the investigation and improvement of prosthetic fit. A miniature triaxial force transducer (4·9×16 mm diameter) has been developed which can be recessed into the socket wall. The principle of operation, construction, performance and limitations of the device are described. Preliminary measurements of the interface stress variations over the gait cycle in a supra-condylar PTB socket are presented. These show clear differences in the stress patterns present when two different prosthetic feet are used.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...