ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Springer  (79)
  • Wiley-Blackwell  (25)
  • National Academy of Sciences  (7)
  • Nature Publishing Group  (3)
  • American Association for the Advancement of Science (AAAS)
  • 1990-1994  (41)
  • 1980-1984  (35)
  • 1970-1974  (28)
  • 1965-1969  (10)
Collection
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 208 (1965), S. 1226-1227 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Since a major step in the formation of gall-stones appears to be the bacterial 7-dehydroxylation of allocholic acid, it is reasonable to assume that the reduction or elimination of the bacteria responsible for the conversion might interfere with gall-stone formation. Because of its well-known ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 243 (1971), S. 154-165 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The generalized Veneziano Model has been applied by Chanet al. to the processes (K¯KΠN¯N) with very impressive results, but in this treatment baryon spin was neglected. In this work we give a covariant spin and isospin decomposition of the above class of processes. Postulating factorization at the lowest meson and baryon poles and using the very stringent duality diagram prescription we are led to a Veneziano type ansatz for the various invariant amplitudes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 313 (1983), S. 369-370 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract It is shown how for temperatures below the critical one (Tc≈20 MeV) the phase diagram of hot nuclear matter may be reconstructed by using experimentally determined cluster abundances from nucleus-nucleus collisions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 16 (1983), S. 347-352 
    ISSN: 1434-6052
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The extended technicolor modelSU(8) ⊃SU(5)×SU(3) c ×U(1)⊃SU TC(3)×SU w(2)×SU c(3) ×U(1) with fermion representations containing three quark lepton families attracts attention because of its unique technicolor coupling: it increases in the infrared circumventing a no-go theorem and further-more stays big over the whole technicolor range. Hence an enhancement of fermion and pseudogoldstone masses proposed by Holdom might happen, allowing for a large sideways scale. A scalar field in the 1015 GeV range introduced in order to break an exact global flavour symmetry of the model is argued to influence strongly the vacuum alignment in the technicolor sector. It permits an explanation of the quark lepton mass pattern even with-out a detailed fit.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Annales geophysicae 12 (1994), S. 1197-1206 
    ISSN: 0992-7689
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract In a series of ozone-sonde soundings at the Hohenpeißenberg observatory, starting in 1967, the most striking features are increases of \sim2.2% per year in all tropospheric heights up to 8 km during the past 24 years. These facts have recently been published and discussed by several authors. In this paper, we present some evidence for the increase of tropospheric ozone concentrations during the past 50 years 1940–1990 in the territory of the northern edge of the Bavarian Alps, including the Hohenpeißenberg data. In December 1940 and August 1942, probably the first exact wet-chemical vertical soundings of ozone up to 9 km height were made by an aircraft in the region mentioned. These results were published in the earlier literature. We have converted the results of the flights on 4 days in December 1940 and on 6 days in August 1942 to modern units and have compared them with the Hohenpeißenberg ozone-sonde data of the December and August months. We also compared the data at the ground with the August results of Paris-Montsouris 1886-1898. Our results show an increase of ozone concentration at all tropospheric heights in Upper Bavaria during the past 50 years, compared with the Montsouris data in August during the past 105 years. In the recently published papers, the increases since 1967 were approximated linearly.Our results, extended to the past, show non-linear trends, with steeper increases since 1975-1979. Possible reasons for these findings are discussed. Quite recently (in case of the December months since 1986/87, the August months since 1990), the ozone mixing ratios at and above Hohenpeißenberg seem to have decreased.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 53 (1966), S. 582-582 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 58 (1971), S. 96-96 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-0649
    Keywords: 85.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Meteorology and atmospheric physics 19 (1970), S. 407-438 
    ISSN: 1436-5065
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geography , Physics
    Description / Table of Contents: Summary For examining the variations of the size distribution in aerosols a recording photoelectrical nucleus counter with three variable expansion degrees has been developed. It is absolutely calibrated by simultaneously photographing the fog droplets in the expansion tube and measuring the extinction. This method gives a secure calibration for every expansion ratio. The recorded concentrations are essentially higher than the values determined with the counter of Scholz, with which a calibration was made by comparison in the usual manner. In contradiction to the statements in other papers a satisfying dissolution into components can be obtained for aerosols which are not too concentrated only be very weak expansions through narrow nozzles. Instead of using the uncertain calculated supersaturation ratios the efficacy of the expansion ratios in dry resp. moist air is determined from direct measurements of the temperature decreases. With the assumption of wettable particles the supersaturation spectra obtained in this way can be transformed into size spectra. These spectra show the variations of the size distribution. The new nucleus counter functions unobjectionably and gives values which are always controlable and without subjective influences.
    Abstract: Résumé Pour des recherches sur les variations de la distribution de la grandeur des aérosols un compteur de noyaux photoélectrique enregistrant avec trois degrés d'expansion a été développé. Son étalonnage a lieu absoluement en photographiant les goutteletes de brouillard dans le tuyau d'expansion sous détermination simultanée de l'extinction. Cette méthode fournit un étalonnage sûr pour chaque degré d'expansion. Les concentrations des noyaux enregistrés sont essentiellement plus hautes que les valeurs du compteur de Scholz, avec lequel un étalonnage de comparaison a été fait de la manière usuelle. Au contraire des résultats publiés dans d'autres publications une décomposition satisfaisante en composantes des aérosols pas trop concentrés peut être obtenue seulement avec des expansions très faibles par des tuyères étroites. Au lieu des valeurs incertaines de sursaturation calculées le rendement des degrés d'expansion pour de l'air sec ou humide est determiné par des mesures directes, des abaissements de la température. Les spectres de sursaturation obtenus peuvent être transformés sour la supposition de particules mouillables, à des distributions de grandeur et laissent reconnaitre les variations des dernières. Le nouveau compteur de noyaux fonctionne irrécusablement et donne des valeurs toujours contrôlables et sans influences subjectives.
    Notes: Zusammenfassung Zu Untersuchungen über die Änderungen der Größenverteilung in Aerosolen wurde ein registrierender fotoelektrischer Kernzähler mit drei variablen Expansionsstufen entwickelt. Seine Eichung erfolgt absolut durch Fotografieren der Nebeltröpfchen im Expansionsrohr bei gleichzeitiger Bestimmung der Extinktion. Diese Methode liefert für jeden Expansionsgrad eine sichere Eichung. Die registrierten Kernkonzentrationen sind wesentlich höher als die Werte beim Scholzschen Kernzähler, mit welchem in der üblichen Weise eine Vergleichseichung vorgenommen wurde. Im Gegensatz zu den in der Literatur veröffentlichten Befunden kann eine befriedigende Komponentenzerlegung bei nicht zu dichten Außenluftaerosolen erst mit sehr schwachen Expansionen durch enge Düsen erzielt werden. Anstelle der unsicheren berechneten, Übersättigungswerte wird der Wirkungsgrad der Expansionsstufen in trockener bzw. feuchter Luft aus direkten Messungen der Temperaturabsenkungen bestimmt. Die so erhaltenen Übersättigungsspektren können unter der Annahme benetzbarer Teilchen befriedigend in Größenverteilungen umgesetzt werden und lassen Änderungen der letzteren deutlich erkennen. Der neue Kernzähler arbeitet einwandfrei und liefert stets kontrollierbare, von subjektiven Einflüssen freie Werte.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Meteorology and atmospheric physics 20 (1971), S. 13-34 
    ISSN: 1436-5065
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geography , Physics
    Description / Table of Contents: Summary The course of temperature during the expansion is measured; by this it is demonstrated in which manner differences between the construction and operation of condensation nuclei counters affect the process of expansion and the degrees of supersaturation reached and falsify the informations about nucleus concentration.
    Abstract: Résumé En mesurant le cours de la température pendant l'expansion on peut constater comment des différences entre la construction et le fonctionnement des compteurs de noyaux de condensation affectent le procès d'expansion et les degrées de sursaturation atteints et comment ils falsifient les informations sur la concentration en noyaux de condensation.
    Notes: Zusammenfassung Durch Messung des Temperaturverlaufs während der Expansion kann festgestellt werden, wie sich Unterschiede in der Konstruktion und der Arbeitsweise bei Kondensationskernzählern auf den Expansionsvorgang und die dabei erzielten Wasserdampfübersättigungen auswirken und die Kernkonzentrationsangaben verfälschen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...