ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • GEOPHYSICS  (2.582)
  • Analytical Chemistry and Spectroscopy  (1.796)
  • 1990-1994  (1.362)
  • 1985-1989  (1.648)
  • 1980-1984  (1.368)
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
Jahr
  • 1
    Publikationsdatum: 2011-08-19
    Beschreibung: An investigation of zircon data from the Mulcahy Lake gabbro, a 63 sq km layered mafic intrusion in the Wabigoon subprovince of Ontario, which show that the gabbro crystallized at 2733.2 +1.0, -0.9 Ma, is considered. It is shown that the gabbro intrudes tholeiites of the Crow Lake-Savant Lake greenstone belt. Whole rock samples and mineral separates from the Mulcahy Lake intrusion are dated by Rb-Sr, Sm-Nd, and Ar-30-Ar-40 techniques. Disturbances in the system are revealed by the Rb-Sr data and an initial Sr ratio of 0.7007 for an age of 2733 Ma is indicated by samples with low Rb/Sr ratios. The age determined for the Sm-Nd data is 2744 + or 55 Ma with an epsilon Nd value of +2.6 + or - 1.2 which indicates a source region depleted in a light rare earth element. Primary hornblende is analyzed for Ar-40/Ar-39 and an age of 2703 + or - 20 is obtained. Some implications for the development of greenstone-granite belts are discussed.
    Schlagwort(e): GEOPHYSICS
    Materialart: Earth and Planetary Science Letters (ISSN 0012-821X); 73; 2-3,
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A method for the quantitative determination of chlorpromazine and five of its major metabolites in a single sample of biological fluid in the ng/ml range has been developed utilizing gas chromatography/mass spectrometry with selected ion recording. The assay is highly specific and quantification is accomplished by an inverse stable isotope dilution technique, using deuterium-labeled variants of the compounds as internal standards. In this way the concentrations of chlorpromazine and five of its major metabolites (the sulfoxide, the N-oxide, the monodemethylated, the didemethylated, and the 7-hydroxylated compounds) can be determined in biological fluids. Levels in humans have been measured both in plasma and in red blood cells and are compared to those found in related in vitro studies.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Publikationsdatum: 2019-07-13
    Beschreibung: Auroral hiss is observed to propagate over distances comparable to an Earth radius from its source in the auroral oval. The role of Landau damping is investigated for upward propagating auroral hiss. By using a ray tracing code and a simplified model of the distribution function, the effect of Landau damping is calculated for auroral hiss propagation through the environment around the auroral oval. Landau damping is found to be the likely mechanism for explaining some of the one-sided auroral hiss funnels observed by Dynamics Explorer 1. It is also found that Landau damping puts a lower limit on the wavelength of auroral hiss. Poleward of the auroral oval, Landau damping is found in a typical case to limit omega/k(sub parallel) to values of 3.4 x 10(exp 4) km/s or greater, corresponding to resonance energies of 3.2 keV or greater and wavelengths of 2 km or greater. For equatorward propagation, omega/k(sub parallel) is limited to values greater than 6.8 x 10(exp 4) km/s, corresponding to resonance energies greater than 13 keV and wavelengths greater than 3 km. Independent estimates based on measured ratios of the magnetic to electric field intensity also show that omega/k(sub parallel) corresponds to resonance energies greater than 1 keV and wavelengths greater than 1 km. These results lead to the difficulty that upgoing electron beams sufficiently energetic to directly generate auroral hiss of the inferred wavelength are not usually observed. A partial transmission mechanism utilizing density discontinuities oblique to the magnetic field is proposed for converting auroral hiss to wavelengths long enough to avoid damping of the wave over long distances. Numerous reflections of the wave in an upwardly flared density cavity could convert waves to significantly increased wavelengths and resonance velocities.
    Schlagwort(e): GEOPHYSICS
    Materialart: Journal of Geophysical Research (ISSN 0148-0227); 99; A2; p. 2471-2488
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A new method for quantitating adenosine concentration by capillary gas chromatography-mass spectrometry-selected ion monitoring (GC-MS-SIM) has been developed and used as a reference method for evaluating a newly developed radioimmunoassay (RIA) for adenosine. Details of the GC-MS-SIM method are presented, along with the comparative results and uncertainties of both methods. General considerations in the statistical analysis of method comparison data are discussed with particular reference to studies using quantitative mass spectrometry as the standard method; the adenosine methods are used as specific examples in this discussion. Simultaneous estimation of the y-intercept and slope of the least squares regression line relating the results of the two methods using the 95% joint confidence ellipse demonstrated the absence of either constant or proportional error between the two methods. The relatively small uncertainty in the GC-MS-SIM measurements had no significant effect on the linear regression. Random error between the two methods was detected, and was estimated by the coefficient of variation in the RIA data as ten percent of the RIA value.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 108-113 
    ISSN: 0951-4198
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: A method is described whereby, under software control, the scan function employed to collisionally excite ions in an ion-trap mass spectrometer is regulated so as to obtain parent ion (fixed product) tandem mass spectral data. At the same time, constant neutral-loss information is also provided. Key features are the automatic ‘intelligent’ selection of parent ions from observation of the initial mass spectrum and the scanning of the applied ‘tickle’ frequency in order to locate the precise resonance points for excitation of these ions. Results for the model compounds perfluorotributylamine (‘FC43’) and n-butylbenzene are reported and complicating effects such as the unimolecular decay of the precursor ion species and charge exchange between product ions and the original sample material are discussed.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 415-417 
    ISSN: 0951-4198
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: The aims of the investigation were to use the method of dynamically programmed scans to study in detail some tandem mass spectrometric characteristics of the ion-trap mass spectrometer and then to use the programs to investigate the possibility of performing benchtop gas chromatography/tandem mass spectrometry experiments on the standard instrument. In particular we have examined the effect of applying a DC ramp during the ‘tickle’ period as a means of broadening the range of resonant frequencies, thereby facilitating the tuning required to effect excitation.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1040-7685
    Schlagwort(e): supercrirical fluid chromatography ; mass spectrometry ; capillary column ; inositol ; phosphate ; phytic acid ; silyl derivatives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Capillary supercritical fluid chromatography with flame ionization detection appears promising for the separation and detection of silylated inositol phosphates. Inositol triphosphate and phytic acid, following ion exchange to their fully protonated forms, were silylated in one step with the addition of 9 and 12 trimethylsilyl groups, respectively. The resulting derivatives are well behaved in open-tubular chromatography columns with methyl-silicone stationary phase when CO2 is used as the mobile phase. Both flow-splitting and directinjection methods were evaluated. The identities of the derivatives were confirmed by supercritical fluid chromatography-mass spectrometry using chemical ionization with both ammonia and isobutane, and using electron ionization - CO2 charge exchange.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatographic mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Selected ion monitoring of vitamin D metabolites has previously been described but there has been only one detailed description of the measurement by gas chromatography/mass spectrometry (GC/MS) of a number of metabolites in a single plasma sample. We describe here a GC/MS method, using stable isotope labelled internal standards, which allows the estimation of vitamins D2 and D3, and their 25-hydroxy, 24,25-dihydroxy and 25,26-dihydroxy metabolites in a single 2 ml sample of plasma, although more is needed for the measurement of 1,25-dihydroxyvitamin D3. Plasma was extracted on Bond Elut C18 cartridges and initial fractionation carried out on Sep-Pak SIL. Straight-phase high-performance liquid chromatography was required for separation of polyhydroxylated metabolites prior to GC/MS using an LKB 2091 mass spectrometer with conventional packed columns. n-Butylboronate esters were formed across vicinal hydroxyls, followed by formation of trimethylsilyl ethers using trimethylsilylimidazole. The [M - 90 - 15]+ ion for each compound was monitored. Deuterated internal standards were not available for all metabolites and it was necessary to use (2H6)D3 and (2H6)25OHD3 as standards for the measurement of D2 and D3, and 25OHD3 and 25OHD2, respectively, and (2H6)24,25(OH)2D3 as a standards for 24,25(OH)2D3 and 25,26(OH)2D2. Although the [M - 90 - 15]+ ion of 24,25(OH)2D and 25,26(OH)2D has the same mass: charge ratio, derivatives of these compounds are completely separated in the GC system used. The intra-assay precision for all these assays is usually less than 5%.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 0030-4921
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The effects of protonation and hydrogen bonding in linear Schiff bases obtained from n-butylamine with butyraldehyde, crotonaldehyde, sorbaldehyde and all-trans-retinal were studied by means of 15N and 13C NMR. The protonation-induced chemical shifts (Δδ) are an order of magnitude larger for 15N than for 13C. For 15N, this effect was found to increase with the extent of conjugation, culminating in the retinylideneimine (Δδ = -146 ppm), which constitutes a model for the study of the structure of the Schiff base linkage in visual pigments and related systems. Theoretical calculations of protonation-induced Δδ values based on MINDO/ 3 are in agreement with experimental results.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...