ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2,405)
  • Polymer and Materials Science  (1,933)
  • Biochemistry and Biotechnology  (368)
  • Physics  (322)
  • Physical Chemistry
  • 1995-1999  (1,462)
  • 1975-1979  (943)
  • 1
    ISSN: 0021-9304
    Keywords: biomaterials ; polyurethanes ; infection ; infection resistance ; surface modification ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Tissue reactions to implantable pacemaker leads were investigated in an early infection model in rabbits. Both standard leads and surface-modified leads were used. The surface modification technique was applied to achieve controlled release of the antibiotic gentamicin. The insulating polyurethane tubing material of the leads was provided with an acrylic acid/acrylamide copolymer surface graft and then loaded with gentamicin. Implantation periods varied from day 4, to week 3½, to week 10. We investigated tissue reactions in the absence of an infectious challenge and also the efficacy of surface-modified leads in preventing infection after challenge with Staphylococcus aureus was evaluated. It was demonstrated that the applied surface modification did not induce adverse effects although during early postimplantation an increase in infiltration of granulocytes and macrophages and wound fluid and fibrin deposition were observed. After bacterial challenge, standard leads were heavily infected at each explantation period, denoted by abscesses, cellular debris, and bacterial colonies. In contrast, little or no infection was observed, either macroscopically or by bacterial cultures, with the surface-modified leads. Microscopy showed little evidence of the bacterial challenge, and that primarily at day 4. It was concluded that the applied surface modification demonstrated enhanced infection resistance and thus represents a sound approach to the battle against infectious complications with biomaterials. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 41, 142-153, 1998.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0006-3592
    Keywords: anaerobic biodegradation ; polychlorinated aliphatics ; acclimation ; enrichment ; polyurethaneactivated carbon carrier ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The simultaneous biodegradation of toxic compounds in mixtures is a major current concern. To bioremediate a toxic mixture, we designed a strategy combining an ad-sorbent carrier with an ecological and nutritional system which allowed work close to heavily polluted conditions in nature. Starting from a methanogenic community, we developed a microbial consortium acclimated to a mixture of about 30 chlorinated aliphatics in a fixed-film stationary-bed bioreactor. Prior to the establishment of a durable period of dechlorination, an interval of progressive dechlorination of the toxic mixture was observed during which the excess of the toxic compounds was stored on the carrier. The latter, consisting of activated carbon in a polyurethane foam, allowed us to work at concentrations far above the solubility of the toxic compounds (apparent concentrations of about 10 g/L). The complete disappearance of hexachloroethane as well as its lower homologues, penta-, tetra-, and trichloroethane, present in the toxic mixture, was observed. Additionally, octachlorocyclopentene, carbon tetrachloride, trichloro-ethylene, tetrachloroethylene, and hexachloro-1,3-butadiene also completely disappeared. For the four latter compounds, from mass balances in the bioreactor, degradation rates around 10 μmol/L per day were determined with total dechlorination. The enrichment culture thus developed exhibited high degradation performances similar to those reported in the literature for pure or enriched anaerobic microbial cultures in contact with a single toxic compound. The results demonstrate the possibility of concurrent high-rate degradation of several highly chlorinated toxic compounds, under conditions approximating field situations.© 1995 John Wiley & Sons, Inc
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The “condensed” counterions which characterize high-charge-density polyelectrolyte solutions can be analyzed into two subpopulations: (1) site-bound counterions and (2) atmospherically entrapped counterions. The distinction is achieved experimentally by combining the data from self-diffusion coefficient or electrical mobility measurements, which give the amount of “condensed” ions, and those from nmr, chemical shift measurements, which indicate the amount of site-bound ions. In the case of a solution of chondroitin sulfate with excess Co++ counterions, it can be estimated that 20% of the structural charge of the polyion is neutralized by site-bound, dehydrated, condensed counterions, while a further 30% is neutralized by atmospherically entrapped, hydrated counterions.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0887-6266
    Keywords: poly(chlorotrifluoroethylene) ; self-orientation ; anisotropic ; annealing ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A peculiar phenomenon is reported whereby a melt-extruded, low-crystallinity, unoriented film of poly(chlorotrifluoroethylene) upon unconstrained thermal treatment, self-extends in the machine direction (MD) while shrinking along the transverse (TD) and normal/thickness (ND) directions. In addition to the expected increase in crystallinity, the annealing process leads to an unexpected development of crystalline orientation along the MD. This phenomenon is an example of “processing-induced memory effects” since it depends on the processing history of the starting film, e.g., melt-extrusion leads to the subject behavior whereas compression molding does not. We must mention that the melt-extruded films of poly(chlorotrifluoroethylene) are isotropic to start with, that is, MD and TD are indistinguishable prior to the annealing process. Furthermore, this phenomenon has not been observed for any other semicrystalline polymer and is believed to be the first citation for poly(chlorotrifluoroethylene) since its commercialization in 1957. Thermomechanical analysis (TMA) is the analytical technique that led to this novel phenomenon which was later substantiated by x-ray diffraction (XRD). ©1995 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 34 (1996), S. 2919-2940 
    ISSN: 0887-6266
    Keywords: interdiffusion ; polymer interfaces ; dynamics ; reptation ; neutron reflection ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Neutron Reflection (NR) and Dynamic Secondary Ion Mass Spectroscopy (DSIMS) experiments were conducted on symmetrically deuterated polystyrene triblock bilayers (HDH/DHD) which directly probed the interdiffusion dynamics of the chains during welding. The HDH chains had their centers deuterated 50%, the DHD chains had their ends deuterated (25% at each end) such that each chain contained approximately 50% D. During welding, anisotropic motion of the chains produces a time-dependent oscillation (ripple) in the H and D concentration at the interface, which bears the characteristic signature of the polymer dynamics. These oscillations were compared with those predicted by Rouse, polymer mode coupling (PMC), and reptation dynamics. The following conclusions can be made from this study. (a) During the interdiffusion of high molecular weight HDH/DHD pairs, higher mobility of the chain ends caused a concentration oscillation which increased to a maximum amplitude, and eventually vanished at times, t 〉 τD. The amplitude, or excess enrichment found, was appreciably more than that predicted by Rouse and PMC simulations, and was only slightly less than that predicted from reptation simulations. (b) The oscillations were completely missing in the 30 and 50K HDH/DHD polymers, which are only weakly entangled. The lack of oscillations for the 30 and 50K pairs may be due to a combination of surface roughness and fluctuations of order 30 Å. (c) It was found that the position of the maximum in this ripple stayed at the interface during its growth. This is also consistent with reptation and has not been explained by other theories. (d) All dynamics models for linear polymers produce ripples, many of which are qualitatively similar to that predicted for reptation. However, each ripple bears the fingerprint of the dynamics in terms of its time-dependent shape, position, and magnitude, and the models are clearly distinguishable. Our results, in summary, support reptation as a candidate mechanism of interdiffusion at polymer(SINGLEBOND) polymer interfaces and its uniqueness is being further pursued. © 1996 John Wiley & Sons, Inc.
    Additional Material: 22 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 34 (1996), S. 3063-3072 
    ISSN: 0887-6266
    Keywords: nano-structured foams ; semicrystalline polymers ; small-angle scattering ; platelet model ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Semicrystalline polymers gelled from thermally quenched semidilute solutions can, in some cases, be supercritically dried to produce nano-structured foams of exceedingly high specific surface area. This article investigates the nano-morphology of these semicrystalline foams. The common morphological feature that these systems display in small-angle scattering can be described by uncorrelated lamellar platelets. The morphological details, which can be obtained using microscopy and small-angle scattering, indicate that these low-density systems occupy a morphological niche between polymeric crystallites from dilute solutions, and spherulitic crystals derived from concentrated solutions and melts. Because these crystalline morphologies occur in concentration ranges between dilute and concentrated, they may offer simple insight into the mechanisms available for distortion of ideal, dilute-solution-derived crystallites as polymer concentration is increased. Several mechanisms for the observed distortions are proposed. © 1996 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 5 (1995), S. 87-99 
    ISSN: 1057-9257
    Keywords: purity ; CdZnTe ; characterization ; IR ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Impurites were tracked from raw material purification through to CdZnTe processing in an effort to identify the sources of elements which impact on IR photodetector performance. Chemical analyses by GDMS and ZCGFAA effectively showed the levels of impurities introduced into CdZnTe substrate material from the manufacturing processes. A new purification process (ISDZR) for raw materials was developed, resulting in improved CdZnTe substrate purity. Substrate CU contamination was found to have detrimental effects on LPE layer and device electrical properties for lightly doped HgCdTe.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0006-3592
    Keywords: diffusion ; biofilms ; gels ; NMR ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The mobility of water in intact biofilms was measured with pulsed field gradient nuclear magnetic resonance (PFG-NMR) and used to characterise their diffusive properties. The results obtained with several well-defined systems, viz. pure water, agar, and agar containing inert particles or active bacteria were compared to glucose diffusion coefficients measured with micro-electrodes and those calculated utilising theoretical diffusion models. A good correspondence was observed indicating that PFG-NMR should also enable the measurement of diffusion coefficients in heterogeneous biological systems. Diffusion coefficients of several types of natural biofilms were measured as well and these results were related to the physical biofilm characteristics. The values had a high accuracy and reflected the properties of a sample of ca. 100 biofilms, while non-uniformity or non-geometrical shapes did not negatively influence the results. The monitored PFG-NMR signal contains supplementary information on e.g. cell fraction or spatial organisation but quantitative analysis was not yet possible. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 60: 283-291, 1998.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 149-155 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The influence of ethylene oxide gas treatment on the in vitro degradation behavior of noncrosslinked, glutaraldehyde crosslinked or hexamethylene diisocyanate crosslinked dermal sheep collagen (DSC) using bacterial collagenase is described. The results obtained were compared with the degradation behavior of either nonsterilized or γ-sterilized DSC. Upon ethylene oxide sterilization, reaction of ethylene oxide with the free amine groups of DSC occurred, which resulted in a decreased helix stability, as indicated by a lowering of the shrinkage temperature of all three types of DSC. Except for the low strain modulus the mechanical properties of the ethylene oxide sterilized materials were not significantly altered. γ-Sterilization induced chain scission in all three types of DSC, resulting in a decrease of both the tensile strength and the high strain modulus of noncrosslinked and crosslinked DSC. When exposed to a solution of bacterial collagenase, ethylene oxide sterilized materials had a lower rate of degradation compared with nonsterilized DSC. This has been explained by a reduced adsorption of the collagenase onto the collagen matrix as a result of the introduction of pendant N-2-hydroxy ethyl groups. © 1995 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...