ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Genetic diversity  (1)
  • Life Sciences (General)  (1)
  • Polymer and Materials Science
  • 2000-2004  (2)
  • 1
    ISSN: 1432-2242
    Keywords: Key words Microsatellite markers ; Wheat ; Genetic diversity ; Genotype identification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract  A set of 20 wheat microsatellite markers was used with 55 elite wheat genotypes to examine their utility (1) in detecting DNA polymorphism, (2)in the identifying genotypes and (3) in estimating genetic diversity among wheat genotypes. The 55 elite genotypes of wheat used in this study originated in 29 countries representing six continents. A total of 155 alleles were detected at 21 loci using the above microsatellite primer pairs (only 1 primer amplified 2 loci; all other primers amplified 1 locus each). Of the 20 primers amplifying 21 loci, 17 primers and their corresponding 18 loci were assigned to 13 different chromosomes (6 chromosomes of the A genome, 5 chromosomes of the B genome and 2 chromosomes of the D genome). The number of alleles per locus ranged from 1 to 13, with an average of 7.4 alleles per locus. The values of average polymorphic information content (PIC) and the marker index (MI) for these markers were estimated to be 0.71 and 0.70, respectively. The (GT)n microsatellites were found to be the most polymorphic. The genetic similarity (GS) coefficient for all possible 1485 pairs of genotypes ranged from 0.05 to 0.88 with an average of 0.23. The dendrogram, prepared on the basis of similarity matrix using the UPGMA algorithm, delineated the above genotypes into two major clusters (I and II), each with two subclusters (Ia, Ib and IIa, IIb). One of these subclusters (Ib) consisted of a solitary genotype (E3111) from Portugal, so that it was unique and diverse with respect to all other genotypes belonging to cluster I and placed in subcluster Ia. Using a set of only 12 primer pairs, we were able to distinguish a maximum of 48 of the above 55 wheat genotypes. The results demonstrate the utility of microsatellite markers for detecting polymorphism leading to genotype identification and for estimating genetic diversity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.
    Keywords: Life Sciences (General)
    Type: Journal of the American College of Cardiology (ISSN 0735-1097); 36; 3; 900-7
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...