ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Institute of Physics  (44)
  • Oxford University Press  (22)
  • American Institute of Physics (AIP)  (19)
  • American Chemical Society (ACS)
  • Wiley-Blackwell
  • 2000-2004  (78)
  • 1955-1959  (14)
Collection
Publisher
Years
Year
  • 11
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 89 (2001), S. 7603-7605 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We report results for μMAG standard problem No. 4, a 500 nm×125 nm×3 nm rectangle of material with properties to mimic Permalloy. Switching dynamics are calculated for fields applied instantaneously to an initial s state: Field 1 at 170° and Field 2 at 190° (−170°) from the positive long axis. Reversal in Field 1 proceeds by propagation of end domains toward the sample center. Reversal in Field 2 involves rotation of the end domains in one direction while the center of the particle rotates in the opposite direction, resulting in collapsing 360° walls with complex dynamics on fine length scales. Approaching the static coercivity, Hc, in small field steps, we find that the ring down frequency, f, and susceptibility, χ, are in approximate agreement with a single spin model that predicts f∝(Hc−H)1/4 and χ∝(Hc−H)−1/2. We show a correlation between the modes of oscillation that become unstable at the critical field and the switching behavior. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 87 (2000), S. 5520-5522 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: For a uniformly magnetized rectangular particle with dimensions in the ratio 5 : 1 : 0.1, the coercive and switching fields in the (1,1,1) direction are determined to be Hc/Ms=0.057069478 and Hs/Ms=0.057142805. Previous micromagnetic computations of coercive and switching fields that did not approach these values for small particles are analyzed. It is shown that the disagreement was primarily due to a disparity in the method of calculating demagnetization energy. Corrected simulations are shown to agree with analytically determined values. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12° above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Three x-ray spectrometers, each with a transmission grating dispersion element, are routinely used at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. Our goal is to make these measurements within an accuracy of ±10%. We periodically characterize the efficiency of the gratings used in the spectrometers by using an electron-impact soft x-ray source, a monochromator, grazing-incidence mirrors, thin filters, and an x-ray charge-coupled device (CCD) detector. We measure the transmission efficiency of the gratings at many photon energies for several grating orders. For each grating, we calculate efficiency as a function of photon energy using published optical constants of gold and multiple-slit Fraunhofer diffraction theory and fit the calculation to the measurements using the physical parameters of the grating as variables. This article describes the measurement apparatus and calibration techniques, discusses the grating efficiency calculation and fitting procedure, and presents recent results.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: X-ray powers on the order of 10 TW over an area of 4.5 mm2 are produced in the axial direction from the compression of a low-density foam target centered within a z-pinch on the Z generator.1 The x rays from this source are used for high-energy–density physics experiments, including the heating of hohlraums for inertial confinements fusion studies.2 In this article, detailed characteristics of this radiation source measured using an upgraded axial-radiation-diagnostic suite3 together with other on- and off-axis diagnostics are summarized and discussed in terms of Eulerian and Lagrangian radiation–magnetohydrodynamic code simulations. The source, characterized here, employs a nested array of 10-mm-long tungsten wires, at radii of 20 and 10 mm, having a total masses of 2 and 1 mg, and wire numbers of 240 and 120, respectively. The target is a 14 mg/cc CH2 foam cylinder of 5 mm diameter. The codes take into account the development of the Rayleigh–Taylor instability in the r–z plane, and provide integrated calculations of the implosion together with the x-ray generation. The radiation exiting the imploding target through the 4.5 mm2 aperture is measured primarily by the axial diagnostic suite that now includes diagnostics at an angle of ∼30° to the z axis. The near on-axis diagnostics include: (1) a seven-element filtered silicon-diode array,4 (2) a five-element filtered x-ray diffraction (XRD) array,5 (3) a six-element filtered PCD array,6 (4) a three-element bolometer,7 (5) time-resolved and time-integrating crystal spectrometers, and (6) two fast-framing x-ray pinhole cameras having 11 frames each. The filtered silicon diodes, XRDs, and PCDs are sensitive to 1–200, 140–2300, and 1000–4000 eV x rays, respectively. They (1) establish the magnitude of the prepluse generated during the run in of the imploding wire arrays, (2) measure the Planckian nature of the dominant thermal, and (3) nonthermal component of the emission. The bolometers and XRDs mounted on the near-normal and 30° LOS (line-of-sight) measure the total power and check the Lambertian nature of the emission. Additionally, a suite of filtered fast-framing x-ray pinhole cameras and silicon-diode arrays behind a transmission grating, mounted on LOSs nearly normal to the z axis, quantify the plasma plume exiting the aperture. The hard bremsstrahlung generated is estimated with both on- and off-axis shielded scintillator photomultiplier diagnostics. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 1223-1223 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Measurements of the hohlraum wall temperature in Z-pinch driven hohlraum experiments require looking through small (2–4 mm diameter) diagnostic holes that undergo some degree of hole closure. The existing soft x-ray diagnostics on Z measure the total flux exiting this diagnostic hole and are therefore affected by this hole closure. To avoid having to measure the effective diagnostic hole area we have designed and constructed an imaging diode array (IDA) that incorporates pinhole imaging and an array of filtered silicon diodes to measure the absolute x-ray intensity from a spatially resolved region of a target. The instrument uses silicon diodes with subnanosecond time response that are sensitive to soft x rays in the range 100–3000 eV. An image of the target area is projected onto the silicon diodes using pinholes. Between each pinhole and it's respective diode is a soft x-ray filter. The material and thickness of the filter are selected to allow unfolding of spectral information in the 100–3000 eV spectral region. We plan to insert a set of grazing-incidence mirrors between each of the filter/diode pairs in a future version of this instrument to better define the spectral bandpass of each diode channel. Radiation from the target region is monitored by a gated microchannel-plate-intensified image recording device that is located immediately behind the diode array. A small shadow in the recorded image corresponds to the specific area of the target that is imaged onto each silicon diode. We are presently fielding this instrument in experiments on the Z facility located at Sandia National Laboratories in Albuquerque, NM. The instrument is located on the same line-of-sight and measures the same spatial region as a filtered fast-framing x-ray pinhole camera and a transmission grating spectrometer. This article describes the design of the IDA diagnostic and presents the results of measurements obtained in hohlraum experiments conducted on Z. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 77 (2000), S. 2491-2493 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We report the results of successful growth of GaN on the C-terminated surface of SiC. A combination of direct heating and hydrogen plasma treatment was employed for surface preparation. High-quality epitaxy was achieved in epilayers as thin as 2000 Å, as evidenced by the x-ray diffraction full width at half maximum of 90 arc sec and 4.2 K donor-bound exciton peak width of 1.4 meV. The epilayers exhibit clear signatures of compressive strain, suggesting a more favorable growth mode than can be achieved on the Si-terminated surface. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 77 (2000), S. 2186-2188 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: High carbon concentrations at distinct regions at thermally-grown SiO2/6H–SiC(0001) interfaces have been detected by electron energy loss spectroscopy (EELS). The thickness of these C-rich regions is estimated to be 10–15 Å. The oxides were grown on n-type 6H–SiC at 1100 °C in a wet O2 ambient for 4 h immediately after cleaning the substrates with the complete RCA process. In contrast, C-rich regions were not detected from EELS analyses of thermally grown SiO2/Si interfaces nor of chemical vapor deposition deposited SiO2/SiC interfaces. Silicon-rich layers within the SiC substrate adjacent to the thermally grown SiO2/SiC interface were also evident. The interface state density Dit in metal–oxide–SiC diodes (with thermally grown SiO2) was approximately 9×1011 cm−2 eV−1 at E−Ev=2.0 eV, which compares well with reported values for SiC metal–oxide–semiconductor (MOS) diodes that have not received a postoxidation anneal. The C-rich regions and the change in SiC stoichiometry may be associated with the higher than desirable Dit's and the low channel mobilities in SiC-based MOS field effect transistors. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 114 (2001), S. 7795-7804 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: We investigate the efficient construction of guiding wave functions for use in diffusion Monte Carlo calculations of electronic excited states. We test guiding wave functions obtained from singles-only configuration interaction, time-dependent density functional theory, and complete active space self-consistent field methods. The techniques are used to study the first ionization potentials and excited states of silane and methane. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 90 (1957), S. 957-962 
    ISSN: 0009-2940
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Die Kondensation, welche Catechine unter der Einwirkung von Säuren erleiden, besteht in der Substitution einer reaktionsfähigen CH-Gruppe des einen -Moleküls durch das Kohlenstoffatom 2 (Phenylcarbinoläthergruppe) des anderen. Dieses Ergebnis wird an vereinfachten Modellen aus der Gruppe der Catechine abgeleitet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...