ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Lunar and Planetary Science and Exploration  (23)
  • Life Sciences (General)  (16)
  • Optics
  • 2005-2009  (15)
  • 2000-2004  (28)
  • 1
    Publication Date: 2011-08-24
    Description: Defining optimal nutrient requirements is critical for ensuring crew health during long-duration space exploration missions. Data pertaining to such nutrient requirements are extremely limited. The primary goal of this study was to better understand nutritional changes that occur during long-duration space flight. We examined body composition, bone metabolism, hematology, general blood chemistry, and blood levels of selected vitamins and minerals in 11 astronauts before and after long-duration (128-195 d) space flight aboard the International Space Station. Dietary intake and limited biochemical measures were assessed during flight. Crew members consumed a mean of 80% of their recommended energy intake, and on landing day their body weight was less (P = 0.051) than before flight. Hematocrit, serum iron, ferritin saturation, and transferrin were decreased and serum ferritin was increased after flight (P 〈 0.05). The finding that other acute-phase proteins were unchanged after flight suggests that the changes in iron metabolism are not likely to be solely a result of an inflammatory response. Urinary 8-hydroxy-2'-deoxyguanosine concentration was greater and RBC superoxide dismutase was less after flight (P 〈 0.05), indicating increased oxidative damage. Despite vitamin D supplement use during flight, serum 25-hydroxycholecalciferol was decreased after flight (P 〈 0.01). Bone resorption was increased after flight, as indicated by several markers. Bone formation, assessed by several markers, did not consistently rise 1 d after landing. These data provide evidence that bone loss, compromised vitamin D status, and oxidative damage are among critical nutritional concerns for long-duration space travelers.
    Keywords: Life Sciences (General)
    Type: The Journal of nutrition (ISSN 0022-3166); Volume 135; 3; 437-43
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: INTRODUCTION: Sustained microvolt-level T wave alternans (TWA) is a marker of increased risk for malignant ventricular arrhythmia. There is a significant risk of arrhythmia and sudden death after repair of congenital heart disease. The aim of this study was to determine the prevalence and characteristics of TWA after repair of tetralogy of Fallot (TOF). METHODS AND RESULTS: TWA was evaluated during bicycle exercise in 49 subjects who had consecutively undergone transatrial-transpulmonary repair. Median values for age, age at repair, and follow-up duration were 14.9 years (11.5-20.8), 1.6 years (0.2-4.9), and 11.6 years (9.4-17.2), respectively. All patients were in New York Heart Association functional class I and were asymptomatic. Median QRS duration was 120 msec (80-150). Sustained TWA was detected in 7 (23%) of 31 subjects with adequate tests. In these 7 subjects, median onset heart rate (HR) was 120 (98-155). Median HR threshold as a percentage of predicted maximum HR (220 - age) was 58% (48-77). Sustained TWA prevalence was not significantly different compared with normal subjects (7/31 vs 9/83; P = 0.1). Onset HR in the TOF group was significantly lower [mean (SD) of 122 (20) vs 139 (12), P 〈 0.05]. In the TOF group with sustained TWA, the TWA occurred in 4 of 7 at 〈60% predicted maximum HR versus 1 of 9 normal subjects (P 〈 0.05); 3 of 7 had onset HR 〈120 versus 0 of 9 normal subjects (P 〈 0.03). There was no significant difference in age, gender, transannular patch use, restrictive right ventricular physiology, QRS duration, QTc, QT/QRS dispersion, or nonsustained ventricular tachycardia in subjects with or those without sustained TWA. CONCLUSION: The onset HR for sustained TWA is significantly lower after repair of TOF. Further study is required to determine whether this represents an increased risk for arrhythmia in this patient group.
    Keywords: Life Sciences (General)
    Type: Journal of cardiovascular electrophysiology (ISSN 1045-3873); Volume 13; 7; 657-61
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P 〈 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.
    Keywords: Life Sciences (General)
    Type: Calcified tissue international (ISSN 0171-967X); Volume 74; 4; 336-41
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-24
    Description: Adequate nutrition is critical during long-term spaceflight, as is the ability to easily monitor dietary intake. A comprehensive nutritional status assessment profile was designed for use before, during and after flight. It included assessment of both dietary intake and biochemical markers of nutritional status. A spaceflight food-frequency questionnaire (FFQ) was developed to evaluate intake of key nutrients during spaceflight. The nutritional status assessment protocol was evaluated during two ground-based closed-chamber studies (60 and 91 d; n = 4/study), and was implemented for two astronauts during 4-mo stays on the Mir space station. Ground-based studies indicated that the FFQ, administered daily or weekly, adequately estimated intake of key nutrients. Chamber subjects maintained prechamber energy intake and body weight. Astronauts tended to eat 40--50% of WHO-predicted energy requirements, and lost 〉10% of preflight body mass. Serum ferritin levels were lower after the chamber stays, despite adequate iron intake. Red blood cell folate concentrations were increased after the chamber studies. Vitamin D stores were decreased by 〉 40% on chamber egress and after spaceflight. Mir crew members had decreased levels of most nutritional indices, but these are difficult to interpret given the insufficient energy intake and loss of body mass. Spaceflight food systems can provide adequate intake of macronutrients, although, as expected, micronutrient intake is a concern for any closed or semiclosed food system. These data demonstrate the utility and importance of nutritional status assessment during spaceflight and of the FFQ during extended-duration spaceflight.
    Keywords: Life Sciences (General)
    Type: The Journal of nutrition (ISSN 0022-3166); Volume 131; 7; 2053-61
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-24
    Description: Ground-based analogs of spaceflight are an important means of studying physiologic and nutritional changes associated with space travel, and the NASA Extreme Environment Mission Operations V (NEEMO) is such an analog. To determine whether saturation diving has nutrition-related effects similar to those of spaceflight, we conducted a clinical nutritional assessment of the NEEMO crew (4 men, 2 women) before, during, and after their 14-d saturation dive. Blood and urine samples were collected before, during, and after the dive. The foods consumed by the crew were typical of the spaceflight food system. A number of physiologic changes were observed, during and after the dive, that are also commonly observed during spaceflight. Hemoglobin and hematocrit were lower (P 〈 0.05) after the dive. Transferrin receptors were significantly lower immediately after the dive. Serum ferritin increased significantly during the dive. There was also evidence indicating that oxidative damage and stress increased during the dive. Glutathione peroxidase and superoxide dismutase decreased during and after the dive (P 〈 0.05). Decreased leptin during the dive (P 〈 0.05) may have been related to the increased stress. Subjects had decreased energy intake and weight loss during the dive, similar to what is observed during spaceflight. Together, these similarities to spaceflight provide a model to use in further defining the physiologic effects of spaceflight and investigating potential countermeasures.
    Keywords: Life Sciences (General)
    Type: The Journal of nutrition (ISSN 0022-3166); Volume 134; 7; 1765-71
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-24
    Description: An axial extensometer able to measure global bone strain magnitudes and rates encountered during physiological activity, and suitable for use in vivo in human subjects, is described. The extensometer uses paired capacitive sensors mounted to intraosseus pins and allows measurement of strain due to bending in the plane of the extensometer as well as uniaxial compression or tension. Data are presented for validation of the device against a surface-mounted strain gage in an acrylic specimen under dynamic four-point bending, with square wave and sinusoidal loading inputs up to 1500 mu epsilon and 20 Hz, representative of physiological strain magnitudes and frequencies. Pearson's correlation coefficient (r) between extensometer and strain gage ranged from 0.960 to 0.999. Mean differences between extensometer and strain gage ranged up to 15.3 mu epsilon. Errors in the extensometer output were directly proportional to the degree of bending that occurs in the specimen, however, these errors were predictable and less than 1 mu epsilon for the loading regime studied. The device is capable of tracking strain rates in excess of 90,000 mu epsilon/s.
    Keywords: Life Sciences (General)
    Type: Journal of biomechanics (ISSN 0021-9290); Volume 34; 3; 385-91
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-24
    Description: A radiative transfer model is used to quantitatively investigate aspects of the martian ultraviolet radiation environment, past and present. Biological action spectra for DNA inactivation and chloroplast (photosystem) inhibition are used to estimate biologically effective irradiances for the martian surface under cloudless skies. Over time Mars has probably experienced an increasingly inhospitable photobiological environment, with present instantaneous DNA weighted irradiances 3.5-fold higher than they may have been on early Mars. This is in contrast to the surface of Earth, which experienced an ozone amelioration of the photobiological environment during the Proterozoic and now has DNA weighted irradiances almost three orders of magnitude lower than early Earth. Although the present-day martian UV flux is similar to that of early Earth and thus may not be a critical limitation to life in the evolutionary context, it is a constraint to an unadapted biota and will rapidly kill spacecraft-borne microbes not covered by a martian dust layer. Microbial strategies for protection against UV radiation are considered in the light of martian photobiological calculations, past and present. Data are also presented for the effects of hypothetical planetary atmospheric manipulations on the martian UV radiation environment with estimates of the biological consequences of such manipulations.
    Keywords: Lunar and Planetary Science and Exploration
    Type: Icarus (ISSN 0019-1035); Volume 146; 2; 343-59
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2018-06-08
    Keywords: Lunar and Planetary Science and Exploration
    Type: 26th General Assembly of the European Geophysical Society; Nice; France
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2018-06-06
    Description: We present the mass X-ray observable scaling relationships for clusters of galaxies using the XMM-Newton cluster catalog of Snowden et al. Our results are roughly consistent with previous observational and theoretical work, with one major exception. We find 2-3 times the scatter around the best fit mass scaling relationships as expected from cluster simulations or seen in other observational studies. We suggest that this is a consequence of using hydrostatic mass, as opposed to virial mass, and is due to the explicit dependence of the hydrostatic mass on the gradients of the temperature and gas density profiles. We find a larger range of slope in the cluster temperature profiles at radii 500 than previous observational studies. Additionally, we find only a weak dependence of the gas mass fraction on cluster mass, consistent with a constant. Our average gas mass fraction results also argue for a closer study of the systematic errors due to instrumental calibration and modeling method variations between analyses. We suggest that a more careful study of the differences between various observational results and with cluster simulations is needed to understand sources of bias and scatter in cosmological studies of galaxy clusters.
    Keywords: Lunar and Planetary Science and Exploration
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2018-06-06
    Description: Determination of the shape of very thin x-ray mirrors employed in spaced-based telescopes continues to be challenging. The mirrors shapes are not readily deduced to the required accuracy because the mount induced distortions are often larger than the uncertainty tolerable for the mission metrology. In addition to static deformations, dynamic and thermal considerations are exacerbated for this class of mirrors. We report on the performance of one temporary mounting scheme for the thin glass mirrors for the Constellation-X mission and prospects for deducing their undistorted shapes.
    Keywords: Optics
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...