ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wiley-Blackwell  (7,565)
  • 2015-2019  (12)
  • 1985-1989  (4,081)
  • 1980-1984  (3,283)
  • 1950-1954  (189)
Collection
Years
Year
  • 11
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 30 (1987), S. 153-156 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The feasibility of using two fertilizers (urea plus superphosphate) in tap water as a medium for the mass culture of green algae (Scenedesmus and Ankistrodesmus) in outdoor plastic-enclosed minipond systems was investigated. Experiments in which the basic fertilizer-tap water medium was enriched with micro- and/or macronutrients revealed no nutrient deficiency symptoms in the algal biomass produced. Biomass production was found to be quantitatively related to the concentration of fertilizer added and maximal production (〉 15 g/m2 day) was achieved following the addition of 30 mg N/L (1.89 g N/m2 day) and 4.5 mg P/L (0.28 g P/m2/day).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 34 (1989), S. 559-562 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 33 (1987), S. 480-487 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The facilitated transport of CO2 through ion exchange membranes containing organic amine counterions was studied. Steady state CO2 fluxes were measured from pure gas streams and mixtures with CH4. Facilitation factors for CO2 up to 26.7 were calculated from transport data. Transport measurements were binary mixtures of CO2 and CH4 yielded ratios of CO2 flux to CH4 flux ranging from 29.0 to 264. Conversion of flux ratios to permeabilities yielded separation factors up to 551 for CO2 over CH4, which are compared to literature data for polymeric membranes. The transport data support a mobile, reactive-carrier facilitated transport mechanism with a carbamate zwitterion complex. Effective diffusivities for CO2 and the carrier-gas complex were determined from transport data. A reaction equilibrium model predicted facilitation factors that were in very good agreement with experimental values. Potential applications are also discussed.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Advanced Materials 1 (1989), S. 399-400 
    ISSN: 0935-9648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 0730-2312
    Keywords: elastase inhibitors ; β-lactams ; lung damage ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Human polymorphonuclear leukocyte elastase (PMN elastase) is inhibited by L-659, 286 (7α-methoxy-8-oxo-3-[[(1,2,5,6-tetrahydro-2-methyl-5,6-dioxo-1,2,4-triaz-in-3-yl)thio]methyl]-5-thia-1-aza-6R-bicyclo [4.2.O]oct-2-ene-2-pyrrolidine carboxamide-5,-dioxide) with a Ki of 0.4 μM. This inhibition is time-dependent, rapid, and only slowly reversible, with a t1/2 of 〉 3 days at 25°C. L-659, 286 is also highly selective for PMN elastase, as it does not inhibit thrombin, trypsin, papain, plasmin, chymotrypsin, or cathepsin G. L-659, 286 administered intratracheally inhibits lung damage caused by administration via the same route of human PMN elastase into hamsters. In marmosets, L-659, 286 is cleared from blood very rapidly after an intravenous injection but is recovered in bronchoalveolar lavage fluid for several hours after intratracheal administration.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 38 (1989), S. 147-162 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The fusion welding behavior of a medium density polyethylene resin has been studied for a wide range of heating rates using a recently developed test methodology. With this method, the thermal and physical phenomena occurring at the interface of two thin polyethylene pieces assembled by fusion can be studied. It consists of a thermal welding phase and a phase of mechanical separation of the welded assembly. For the mechanical phase, an adaptation of the T-peel test was used. These conditions make it possible to determine the thermal welding parameters (temperature, time) for optimal mechanical quality of the joint, according to a criterion established by optimization of the peel test used. The variations in minimum temperature required for an optimum weld, as a function of heating rate, can be simulated with a numerical model based on the concept of macromolecular interdiffusion. Consistent with the experimental behavior, the numerical model involves two parameters characteristic of the diffusion behavior of the polyethylene resin. Thus, these parameters characterize the weldability of the polyethylene resin under study.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for quantitating adenosine concentration by capillary gas chromatography-mass spectrometry-selected ion monitoring (GC-MS-SIM) has been developed and used as a reference method for evaluating a newly developed radioimmunoassay (RIA) for adenosine. Details of the GC-MS-SIM method are presented, along with the comparative results and uncertainties of both methods. General considerations in the statistical analysis of method comparison data are discussed with particular reference to studies using quantitative mass spectrometry as the standard method; the adenosine methods are used as specific examples in this discussion. Simultaneous estimation of the y-intercept and slope of the least squares regression line relating the results of the two methods using the 95% joint confidence ellipse demonstrated the absence of either constant or proportional error between the two methods. The relatively small uncertainty in the GC-MS-SIM measurements had no significant effect on the linear regression. Random error between the two methods was detected, and was estimated by the coefficient of variation in the RIA data as ten percent of the RIA value.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1040-7685
    Keywords: supercrirical fluid chromatography ; mass spectrometry ; capillary column ; inositol ; phosphate ; phytic acid ; silyl derivatives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary supercritical fluid chromatography with flame ionization detection appears promising for the separation and detection of silylated inositol phosphates. Inositol triphosphate and phytic acid, following ion exchange to their fully protonated forms, were silylated in one step with the addition of 9 and 12 trimethylsilyl groups, respectively. The resulting derivatives are well behaved in open-tubular chromatography columns with methyl-silicone stationary phase when CO2 is used as the mobile phase. Both flow-splitting and directinjection methods were evaluated. The identities of the derivatives were confirmed by supercritical fluid chromatography-mass spectrometry using chemical ionization with both ammonia and isobutane, and using electron ionization - CO2 charge exchange.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatographic mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Selected ion monitoring of vitamin D metabolites has previously been described but there has been only one detailed description of the measurement by gas chromatography/mass spectrometry (GC/MS) of a number of metabolites in a single plasma sample. We describe here a GC/MS method, using stable isotope labelled internal standards, which allows the estimation of vitamins D2 and D3, and their 25-hydroxy, 24,25-dihydroxy and 25,26-dihydroxy metabolites in a single 2 ml sample of plasma, although more is needed for the measurement of 1,25-dihydroxyvitamin D3. Plasma was extracted on Bond Elut C18 cartridges and initial fractionation carried out on Sep-Pak SIL. Straight-phase high-performance liquid chromatography was required for separation of polyhydroxylated metabolites prior to GC/MS using an LKB 2091 mass spectrometer with conventional packed columns. n-Butylboronate esters were formed across vicinal hydroxyls, followed by formation of trimethylsilyl ethers using trimethylsilylimidazole. The [M - 90 - 15]+ ion for each compound was monitored. Deuterated internal standards were not available for all metabolites and it was necessary to use (2H6)D3 and (2H6)25OHD3 as standards for the measurement of D2 and D3, and 25OHD3 and 25OHD2, respectively, and (2H6)24,25(OH)2D3 as a standards for 24,25(OH)2D3 and 25,26(OH)2D2. Although the [M - 90 - 15]+ ion of 24,25(OH)2D and 25,26(OH)2D has the same mass: charge ratio, derivatives of these compounds are completely separated in the GC system used. The intra-assay precision for all these assays is usually less than 5%.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...