ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 42.65. - k  (1)
  • Column technology  (1)
  • Springer  (2)
  • American Association for the Advancement of Science
  • 2015-2019
  • 2005-2009
  • 1995-1999  (2)
Collection
Publisher
  • Springer  (2)
  • American Association for the Advancement of Science
Years
  • 2015-2019
  • 2005-2009
  • 1995-1999  (2)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 61 (1995), S. 377-384 
    ISSN: 1432-0649
    Keywords: 42.65. - k ; 78.66.Qn ; 82.30.Qt
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Studies on the dynamic behaviours of laser-induced gratings through two-photon absorption and single-photon absorption were carried out in an azobenzene-doped PMMA film. The experimental results exposed the structures of energy levels and the relaxation between them, in which different lifetimes of the triplet states of trans and cis isomers of azobenzene molecule were recognized. The temporal characteristics of the diffracted signal from the induced-gratings showed also the dynamic processes of the photoisomerization reaction between two isomers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Capillary electrophoresis ; Column technology ; Deactivation ; Polyethyleneoxides ; Ribonucleotides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this study, a variety of fused silica capillaries with different combinations and sequences of treatments with HMDS and polyethylene oxide were prepared in order to develop an optimized column modification method for analysis of ribonucleotides. The 12 most common ribonucleotides (UTP, CTP, ATP, GTP, UDP, CDP, ADP, GDP, UMP, CMP, AMP, and GMP) in human cells were used as test solutes. Column performance measurements, including electroosmotic flow (EOF), solute migration speed and retention, column efficiency, peak shape, and resolution were investigated. By analyzing solute migration speed and retention of various hydrophilic/hydrophobic solutes, the column wall effects (EOF and adsorption) can be distinguished. This analysis method can give guidance in optimizing polymer coating properties (hydrophilicity/hydrophobicity) for CE columns. By studying the performance of these columns after various surface treatments, we were able to improve the separation of ribonucleotides from real samples to within 16 minutes with high efficiency and stability (over 300 analyses) using columns first deactivated with hexamethyldisilazane, and then coated with polyethylene oxide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...