ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (196)
  • Springer  (132)
  • Springer Nature  (41)
  • National Academy of Sciences  (23)
  • American Meteorological Society (AMS)
  • 2020-2022  (49)
  • 2000-2004  (30)
  • 1980-1984  (71)
  • 1955-1959  (8)
  • 1950-1954  (10)
  • 1935-1939  (28)
Collection
  • Articles  (196)
Years
Year
Journal
  • 1
  • 2
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The formalism for fragment angular distributions in photofission with unpolarized and linearly polarized photons is summarized. First experiments on232Th using linearly polarized bremsstrahlung are described. The results for the analyzing power show for the first time in a model independent way that the low energy photofission can be explained byelectric dipole excitation. The possibilities of this new method are discussed, in particular when using monoenergetic tagged photons, which are available soon at new high duty cycle electron accelerators.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 30 (1981), S. 176-180 
    ISSN: 1570-7458
    Keywords: Western Spruce Budworm ; Choristoneura occidentalis ; Glypta fumiferanae ; endoparasitoids ; electrophoresis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Zusammenfassung Raupen von Choristoneura occidentalis ohne und mit dem Endoparasitoiden Glypta fumiferanae (Vier.) (Hymenoptera: Ichneumonidae) wurden elektrophoretisch auf Isoenzymbänder untersucht zum Nachweis des Parasitoiden. Für G. fumiferanae typische Bänder wurden in 4 der untersuchten 15 Enzymen beobachtet. Dies waren Aconitase, Esterase, Leucinaminopeptidase und 6-Phosphoglucose-dehydrogenase. Das Vorkommen dieser Isoenzymbänder ist ein zuverlässiges Zeichen der Parasitierung durch G. fumiferanae. Die Brauchbarkeit der Elektrophorese als Mittel zum Routinenachweis von Parasitoiden wird diskutiert.
    Notes: Abstract Parasitoid-free western spruce budworms and western spruce budworm larvae containing the endoparasitoid Glypta fumiferanae (Vier.) (Hymenoptera: Ichneumonidae) were assayed electrophoretically to identify isozyme bands diagnostic for the parasitoid. Bands characteristic of G. fumiferanae were observed with 4 of 15 enzymes tested. These were aconitase, esterase, leucine aminopeptidase and 6-phosphoglucose dehydrogenase. Presence of these isozyme bands is a reliable indication of parasitism by G. fumiferanae. The efficiency of electrophoresis as a tool for routine detection of parasitoids is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1572-8382
    Keywords: dialogue systems ; multilingual NL generation ; natural language processing ; public administration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Law
    Notes: Abstract This paper presents two projects concerned with the application of natural language processing technology for improving communication between Public Administration and citizens. The first project, GIST,is concerned with automatic multilingual generation of instructional texts for form-filling. The second project, TAMIC, aims at providing an interface for interactive access to information, centered on natural language processing and supposed to be used by the clerk but with the active participation of the citizen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 760-769 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Verfasser haben eine semimikro- und eine mikrogravimetrische Methode und ein spektrophotometrisches Verfahren zur Bestimmung von Calcium mit Loretin (7-Jod-8-hydroxychinolin-5-sulfonsäure) ausgearbeitet. Nach Festlegung des Umrechnungsfaktors des Calciumloretinats auf gravimetrischem und thermogravimetrischem Wege wurde gezeigt, daß durch Semimikrogravimetrie Calciummengen von 5 bis 50 mg mit einem mittleren Fehler von 0,35% bestimmbar sind. Die mikrogravimetrische Methode eignet sieh für 0,2 mg Calcium/ml mit einem mittleren Fehler von 0,45%. Der Einfluß einer Reihe von Fremdionen wurde untersucht. Die meisten davon stören nicht, auch wenn sie in bedeutender Menge vorhanden sind. Durch indirekte Spektrophotometrie, nämlich durch Auflösen des Calciumloretinats in überschüssiger Eisen(III)lösung gelang es, Calciummengen in der Größenordnung von 20μg mit einem mittleren Fehler von 0,35% zu bestimmen.
    Abstract: Summary The authors have elaborated a method (semi-micro and micro-gravimetric) and also a spectrophotometric method for determining calcium by means of loretin. After establishing the analytical factor for calcium loretinate by the gravimetric and the thermogravimetric methods, they showed the possibility of determining calcium on the semimicro gravimetric scale for quantities ranging from 5 mg to 50 mg, the mean error being 0.35%. The microgravimetric method allows the minimum quantity to be determined to be reduced to 0.2 mg calcium per ml, the mean error being 0.45%. A study was made of the influence of a number of foreign ions. Most of them do not harm the determination, even though they are present in considerable amounts. By indirect spectrophotometry, notably by dissolving the calcium loretinate in an excess of ferric solution, the writers have succeeded in determining amounts of calcium of the order of 20μg with a mean error of 0.35%.
    Notes: Résumé Les auteurs ont élaboré une méthode semi-micro et micro-gravimétrique et une méthode spectrophotométrique pour le dosage du calcium par la lorétine. Après avoir établi le facteur analytique du lorétinate de calcium par voie gravimétrique et thermogravimétrique, ils ont démontré la possibilité de doser le calcium à l'échelle semi-micro gravimétrique pour des quantités allant de 5 mg à 50 mg, l'erreur moyenne étant de 0,35%. La méthode microgravimétrique permet de ramener la quantité minima à doser à 0,2 mg de calcium par ml, l'erreur moyenne étant de 0,45%. L'influence d'une série d'ions étrangers fut étudiée. La plupart ne gênent pas le dosage, même s'ils sont présents en quantités importantes. Par spectrophotométrie indirecte, notamment en redissolvant le lorétinate de calcium dans un excès d'une solution ferrique, les auteurs ont réussi à doser des quantités de calcium de l'ordre de 20μg avec une erreur moyenne de 0,35%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1436-5073
    Keywords: Key words: Aluminium; plasma-assisted nitriding; AlN; AES; TEM.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract.  Detailed examinations were made by AES depth profiling, SEM, TEM and electron diffraction to get information about the relation between treatment conditions and the state of plasma-nitrided aluminium. The chemical composition and the elemental depth distribution were proofed to be depending on gas phase mixture, pressure and temperature during plasma treatment. The admixture of hydrogen during presputtering for surface cleaning and during nitriding results both in an improved nitriding behaviour and in a reduction of the formation of conical-shaped particles at the surface. The microstructure of the nitride layer isn’t depending on tested process conditions significantly. Surface and interface between layer and substrate are roughly in a scale of a few ten nanometers owing to sputtering effects. The main phase inside the layer is nanocrystalline AlN of the known hexagonal modification. In addition, some crystallites of remaining aluminium are present as a second phase. In contrast to nitrogen-implanted aluminium no preferred lattice orientation of the AlN phase was evident.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 41 (1953), S. 89-118 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es werden etwa 70 mikrochemische und andere Apparate beschrieben, die in den vergangenen 10 Jahren entwickelt wurden. Es handelt sich hierbei um Geräte zum Rühren u. dgl., Einrichtungen für die anorganische qualitative Analyse, Apparate für organische Zwecke, für elektrochemische und volumetrische Verfahren und für verschiedene andere Bedürfnisse.
    Abstract: Résumé On décrit environ 70 articles relatifs à l'appareillage microchimique et général mis au point pendant les 10 dernières années. L'appareillage est classé en 6 sections, c'est-à-dire, dispositifs pour l'agitation et ce qui s'y rapporte, pour l'analyse qualitative minérale, l'appareillage organique, les techniques électrochimiques, l'appareillage pour Volumétrie et des dispositifs variés.
    Notes: Summary About 70 pieces of microchemical and general apparatus developed during the past 10 years are described. The apparatus is classified in 6 sections, viz. stirring and allied devices, equipment for inorganic qualitative analysis, organic apparatus, electrochemical techniques, volumetric apparatus, and miscellaneous devices.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1572-9672
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Two FUV Spectral imaging instruments, the Spectrographic Imager (SI) and the Geocorona Photometer (GEO) provide IMAGE with simultaneous global maps of the hydrogen (121.8 nm) and oxygen 135.6 nm components of the terrestrial aurora and with observations of the three dimensional distribution of neutral hydrogen in the magnetosphere (121.6 nm). The SI is a novel instrument type, in which spectral separation and imaging functions are independent of each other. In this instrument, two-dimensional images are produced on two detectors, and the images are spectrally filtered by a spectrograph part of the instrument. One of the two detectors images the Doppler-shifted Lyman-α while rejecting the geocoronal `cold’ Ly-α, and another detector images the OI 135.6 nm emission. The spectrograph is an all-reflective Wadsworth configuration in which a grill arrangement is used to block most of the cold, un-Doppler-shifted geocoronal emission at 121.567 nm. The SI calibration established that the upper limit of transmission at cold geocoronal Ly-α is less than 2%. The measured light collecting efficiency was 0.01 and 0.008 cm2 at 121.8 and at 135.6 nm, respectively. This is consistent with the size of the input aperture, the optical transmission, and the photocathode efficiency. The expected sensitivity is 1.8×10−2 and 1.3×10−2 counts per Rayleigh per pixel for each 5 s viewing exposure per satellite revolution (120 s). The measured spatial resolution is better than the 128×128 pixel matrix over the 15°×15° field of view in both wavelength channels. The SI detectors are photon counting devices using the cross delay line principle. In each detector a triple stack microchannel plate (MCP) amplifies the photo-electronic charge which is then deposited on a specially configured anode array. The position of the photon event is measured by digitizing the time delay between the pulses detected at each end of the anode structures. This scheme is intrinsically faster than systems that use charge division and it has a further advantage that it saturates more gradually at high count rates. The geocoronal Ly-α is measured by a three-channel photometer system (GEO) which is a separate instrument. Each photometer has a built in MgF2 lens to restrict the field of view to one degree and a ceramic electron multiplier with a KBr photocathode. One of the tubes is pointing radially outward perpendicular to the axis of satellite rotation. The optic of the other two subtend 60° with the rotation axis. These instruments take data continuously at 3 samples per second and rely on the combination of satellite rotation and orbital motion to scan the hydrogen cloud surrounding the earth. The detective efficiencies (effective quantum efficiency including windows) of the three tubes at Ly-α are between 6 and 10%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Applied microbiology and biotechnology 18 (1983), S. 86-91 
    ISSN: 1432-0614
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Summary A method for the production of spherical alginate gels from few μm up to several mm diameter is described. Alginate beads with diameters from 0.5 to 3 mm are used to immobilize microorganisms as biocatalysts. Micro size alginate gels are used as column packing material for inverse steric exclusion chromatography to determine their pore sizes from dextran standards of known molecular weight. The results indicate that alginate gels have pores which are large enough to release catalytic acting enzymes out of the matrix.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für angewandte Mathematik und Physik 5 (1954), S. 168-172 
    ISSN: 1420-9039
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Physics
    Notes: Zusammenfassung Für eine programmgesteuerte Rechenmaschine mit einer magnetischen Trommel als Speicher wird ein für den allgemeinen Gebrauch geeignetes Verzeichnis der arithmetischen Befehle gegeben und der logische Aufbau des Rechenwerks beschrieben. Vorgesehen ist das Rechnen sowohl mit gleitendem Komma (Zahlen der Forma·10 b ) als mit festem Komma, was das automatische Berechnen von Rechenplänen sowie das Rechnen mit verdoppelter Stellenzahl gestattet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...