ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (17)
  • Springer  (17)
  • American Chemical Society
  • American Institute of Physics
  • American Institute of Physics (AIP)
  • Nature Publishing Group
  • Oxford University Press
  • Wiley
  • 2020-2022
  • 1990-1994  (17)
  • 1993  (17)
Collection
Keywords
Publisher
  • Springer  (17)
  • American Chemical Society
  • American Institute of Physics
  • American Institute of Physics (AIP)
  • Nature Publishing Group
  • +
Years
  • 2020-2022
  • 1990-1994  (17)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 295-301 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Used column packings ; Particle size distribution ; Scanning electron microscopy ; Column age
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Particle size distribution analysis and scanning electron microscopy (SEM) were carried out on eight used HPLC columns containing either irregular silica based, spherical silica based or spherical polymer based packing material. Particle size distributions of the used irregular silica based columns were at least bimodat at the outlet ends and either biomodal or log-normal at the inlet ends with regular progressions between the two extremes through the column. A new ODS-3 column showed log-normal size distributions from the inlet to the outlet ends. Spherical silica based column particle size distributions showed distinct shoulders on large central distribution peaks in most column sections with various degrees of shoulder erosion. The spherical resin based column showed a broader inlet particle size distribution progressing to a very narrow outlet distribution. SEMs of both irregular and spherical silica based columns revealed a larger number of undersized particles and debris at the outlet than inlet ends which could have resulted from stationary phase degradation, since this was not seen in the new ODS-3 column. While several SEMs of the spherical silica based columns revealed hollow spheres and twins, the spherical resin based column packing showed stress fractures or wrinkle lines resulting from use or dehydration.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fullerenes ; FullereneSep® ; Separation factor ; HPLC-particle beam mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary High-performance liquid chromatographic separation of fullerene mixtures in the range C60 to C100 can be achieved using a novel stationary phase which rivals the performance of the more expensive ‘Pirkle-type’ columns currently employed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Glutamine ; Pyroglutamic acid ; Amino acids formulations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The aminoacid glutamine in aqueous solution and in conditions of high temperature and long term storage is partly transformed into pyroglutamic acid which exhibits potential neurotoxic effects. Commercially available aminoacid mixtures supplemented with glutamine are heat-sterilized and some losses of glutamine and formation of pyroglutamic acid may occur. The aim of the work was to set up an easy and reliable HPLC method which allows the determination of pyroglutamic acid as a degradation product of glutamine. The column was a 5 μm Hypersil ODS (100×4.6 mm) and the mobile phase 100% 0.007 M phosphate buffer pH 3.5. Stability studies in different conditions of temperature and time of storage were performed on aminoacid mixture available in the commerce.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Immunoaffinity chromatography ; Proteins ; Surface plasmon resonance detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The BIAcoreTM Biosensor System utilizes a detection principle known as Surface Plasmon Resonance (SPR) which, in simple terms, detects changes in the refractive index of a solution in contact with a gold film. The gold film is surface modified with carboxymethylated dextran to produce a hydrophillic matrix onto which macromolecules may be covalently immobilized. In this respect, the BIAcoreTM is similar to any other insoluble matrix, such as a chromatographic support. The SPR detection principle, however, allows one to directly ‘visualize’ the interaction under study, in real time and without the need for reporter molecules such as enzyme-labels. In addition, the very small sample requirements, automated robotics unit and ease of data analysis suggest the potential use of the BIAcoreTM instrumentation for assay development and possibly process development, especially where bio-specific interactions such as immunoaffinity chromatography are used as a step in the process. In this report, we demonstrate the use of the BIAcoreTM SPR detector for the micro-scale determination of conditions for immunoaffinity chromatography of soluble complementreceptor 1, sCR1.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 55-60 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Carbohydrates ; Ion-pair separation ; Glycoconjugates ; PRP-1 and PLRP-S
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new technique for the separation of carbohydrates as ion-pairs in strongly alkaline solution is presented. Carbohydrates are weakly acidic and partly present as anions at pH≥12 [1]. They are retained as ion-pairs on polymeric solid phases (PRP-1 and PLRP-S) with a hydrophobic quaternary ammonium counter ion present in the mobile phase. The effects of nature and concentration of mobile phase components on the retention of carbohydrates have been investigated and an ion-pair distribution model is proposed. The influence of temperature indicated no changes in retention mechanism with high counter ion concentration, but the resolution decreased with increasing temperature. Saccharides added to the mobile phase were shown to increase the retention and the selectivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; 18 β-glycyrrhetinic acid ; Glycyrrhizinic acid ; Toothpastes ; Solid phase extraction (SPE)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary HPLC methods suitable for the selective and sensitive determination of 18 β-Glycyrrhetinic acid (GT) and Glycyrrhizinic acid (GZ) in toothpastes have been developed. The methods involve a preliminary quantitative solid phase extraction (C-18 sorbent) for sample clean-up and analyte concentration. Chromatographic separations were performed on reversed phase (C-8; C-18) columns using mixtures of methanol and phosphate buffers (pH 3.0) as the mobile phase under isocratic or gradient elution conditions. The method were applied successfully to the analysis of commercial toothpastes containing low levels (0.013–0.065%) of GT and GZ.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Pre-column derivatisation ; Morpholine and degradation products ; Boiler feed water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Morpholine and its amine-type thermal degradation products present in boiler feed water and steam condensate were derivatised with N-succinimidyl-p-nitrophenylacetate. These pre-column derivatives were determined by high-performance liquid chromatography with UV detection at 280 nm. The analytical column was Supelco-sil-ODS with an isocratic mobile phase. Morpholine and its breakdown products were monitored in the range 0.01–10 μg ml−1 with a relative standard deviation of 0.4–3.0%. Chromatographic analysis of boiler feed water and steam condensate samples collected from a boiler servicing a petroleum refinery is described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; 1,4-Benzoxazin-3-ones ; Cyclic hydroxamic acids ; β-Cyclodextrin modified silica gel ; Enantiomer separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A liquid chromatographic procedure on a 5 μm LiChroCART column using chemically bonded β-cyclodextrin (ChiraDex) as chiral selector was developed for the enantiomeric separation of four 2H-1,4-benzoxazin-3(4H)-ones which are close analogs of the cyclic hydroxamic acids 2,4-dihydroxy-2H-1,4-benzoxazin-3(4H)-one (DIBOA) and 2,4-dihydroxy-7-methoxy-2H-1,4-benzoxazin-3 (4H)-one (DIMBOA) naturally occurring inGramineae species.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 435-438 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Pirarubicin and metabolites ; Anthracyclines
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new and highly sensitive HPLC method for the simultaneous determination of pirarubicine (THP-doxorubicin) and its metabolites, adriamycin and adriamycinol, in human plasma, is described. Samples were treated by liquid-liquid extraction, the organic phase removed and the residue dissolved in methanol. Separation was on a Lichrocart Supersher RP 8 column, (250×4 mm) 4 μm, with a mobile phase of acetonitrile/methanol/formate-buffer.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; UV and electrochemical detectors ; Phenolic antioxidants ; Migration studies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The performance of UV diode-array, spectrometric and electrochemical detectors was compared in the chromatographic analysis of trace amounts of six phenolic antioxidants. Quantitative validation was undertaken; the linearity range was wider using UV detection although the limits of detection were lower with electrochemical detection. UV detection was applied both to identification of an antioxidant in a hydrophilic suspension and to a migration study.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...