ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography
  • Springer  (5)
  • Wiley-Blackwell  (4)
  • American Chemical Society
  • American Physical Society
  • Cambridge University Press
  • International Union of Crystallography (IUCr)
  • 1985-1989  (9)
  • 1980-1984
  • 1965-1969
  • 1955-1959
  • 1945-1949
  • 1989  (9)
Collection
Publisher
  • Springer  (5)
  • Wiley-Blackwell  (4)
  • American Chemical Society
  • American Physical Society
  • Cambridge University Press
  • +
Years
  • 1985-1989  (9)
  • 1980-1984
  • 1965-1969
  • 1955-1959
  • 1945-1949
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 28 (1989), S. 24-26 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Anesthetics ; Pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A sensitive capillary gas chromatographic method is described for the simultaneous determination of lidocaine, tetracaine, procaine and dibucaine. The method was applied to the determination of anesthetics in tissue homogenates incubated at 38°C at doses between 10 and 400 mg/kg. In the liver tissue thein vitro metabolization of the studied anesthetics is most rapid for tetracaine, also fast for procaine, while for lidocaine and dibucaine the metabolization is very slow. In brain tissue thein vitro metabolization of anesthetics is very slow. The method shows good analytical parameters: linearity between 5 and 40 μg/ml; day-to-day reproducibility ca. 8% for a concentration of 20 μg/ml, precision ca. 7% for a concentration of 20μg/ml. Accuracy is also very good.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; FAME fingerprinting ; Animal fats ; Transesterification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The triglycerides of animal fats from milk, meat or cheese can also be characterized by the gaschromatographic pattern of the fatty acid methylesters (FAME) after conversion by an unsophisticated transesterification procedure. Even from the FAME pattern falsifications of commercial animal fats can be revealed by the fast separation of the FAME using a standard CW 20 M (polyethyleneglycol) capillary column. Characteristic patterns of FAME originating from different animals are shown. The patterns of the FAME from different races of the same animal are very similar, so that the characterisation according to the type of animal is not disturbed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 27 (1989), S. 182-184 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Micropacked columns ; Alkyl-modified silica ; Hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Micropacked columns for liquid chromatography were evaluated for the gas chromatographic separation of hydrocarbons. A glass-lined stainless-steel tube of 30 cm×0.3 mm i.d., packed with 5-μm alkyl-modified silica, was employed as the separation column. The micropacked columns were successfully applied to the separation of components of a light oil and a kerosine.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 27 (1989), S. 436-440 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid crystal stationary phases ; PAH ; FAME ; Mesomorphic polysiloxane phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The gas-chromatographic properties of two mesomorphic polysiloxane (MEPSIL) stationary phases, one smectic (SB) and the other nematic (N), were investigated. The retention indices and separation factors (relative retentions), α, of several pairs of polycyclic aromatic hydrocarbon (PAH) and fatty acid methyl ester (FAME) isomer solutes were used to gauge differences in the selectivity provided by each. The heats of solution of the PAH showed that the smectic MEPSIL is more selective for solutes with different length-to-breadth ratios. Also, five peaks were resolved for sixcis andtrans octadecenoic FAME isomers with this solvent. The nematic MEPSIL, on the other hand, was found to be more useful at higher temperatures because of its higher clearing point. In addition, solute capacity factors were smaller than those observed with the smectic MEPSIL, as evidenced by lower retention indices. The former was therefore more useful for the analysis of high molecular-weight PAH.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Microwave plasma detector ; Thiophenes ; Shale oil distillates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A series of alkylthiophenes and dimethyl disulfide were tentatively identified in an oil shale retort gas condensate from a 6-kg bench-scale retort using gas chromatography with a microwave-induced helium plasma detector (GC-MIP). The sulfur species were present in concentrations ranging from 1.5 to 10.7 mol ppm in the undiluted offgas. The GC-MIP technique was successful in selectively detecting the sulfur components in the complex mixture. Quantitation was simplified relative to GC with flame-photometric detection because of the absence of quenching or other interference problems at the concentrations studied. Attempts to determine stoichiometry of the sulfur components by comparison of carbon, hydrogen, and sulfur ratios with those of standards were unsuccessful because of the complexity of the carbon and hydrogen chromatograms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 193-207 
    ISSN: 0935-6304
    Keywords: Multidimensional chromatography ; Liquid chromatography ; Gas chromatography ; Gupercritical fluid chromatography ; Fuels ; Foodstuffs ; Environmental ; Biological ; Pharmaceutical ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Although coupled liquid chromatographygas chromatography (LC-GC) was first demonstrated ten years ago, only in the last few years has there been a sudden surge of interest in the technique. Approximately 70% of the total number of LC-GC applications have been published in the last two years (1987-88) alone. This review categorizes LC-GC publications into four main application areas: fossil fuels, foods, environmental samples, biologiical/pharmaceutical samples, and miscellaneous samples. Multidimensional separations carried out using other coupled-column chromatographic techniques (such as supercritical fluid chromatography (SFC) with GC, and on-line trace enrichment-GC) have also been included in this review.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Purge-and-trap ; Cryogenic focusing ; Splitless injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new configuration for coupling a purge-and-trap unit to a capillary column gas chromatograph via a cryogenic focusing interface has been developed. In this configuration, the precolumn of the cryogenic focusing interface was inserted through the septum of a split/splitless injection port where it served as both sample transfer and carrier gas supply lines. The injection port of the gas chromatograph was modified by plugging the carrier gas and the septum purge lines. This configuration allowed for the desorption of analytes at high flow rates while maintaining low, analytical-column flow rates which are necessary for optimum capillary column operation. The capillary column flow rate is still controlled by the column backpressure regulator. Chromatograms of purgeable aromatics exhibited improved resolution, especially for early eluting components compared to those obtained by direct liquid injection using the normal splitless injection mode. Quantitative sample transfer to the analytical column afforded excellent linearity and reproducibility of compounds studied.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 234-238 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed column ; Wide bore column ; Fused silica column ; Amino acids ; Cerebrospinal fluid (CSF) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the present study, the use of gas chromatography (GC) for the determination of amino acids in human cerebrospinal fluid (CSF) is described. Although some amino acids may be determined using a packed column following the removal of glucose, the major interfering component, the inadequate resolution of other amino acids from remaining unidentified components results in poor quantitation. The use of wide bore columns improves reproducibility considerably, but still it does not provide sufficient resolution to enable quantitative determination of all amino acids in human CSF. Good reproducibility data, with CV values for all amino acids of 7% or less and recoveries generally between 80% and 100%, can only be obtained using the fused silica open tubular (FSOT) column. Normal amino acid levels are presented for 10 samples of human CSF, which compare well with data previously reported in the literature.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 437-441 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica column ; Amino acids ; Urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This report describes a convenient means of reducing the complex matrix which is responsible for interference during gas chromatographic determination of amino acids in urine. The pre-chromatographic clean-up employs the principle of solid phase extraction using bonded silica incorporating cation exchange groups. This approach avoids the detrimental effects on amino acid recoveries associated with resin-based cation exchangers. In spite of significant reduction in the complexity of chromatograms, only the high efficiency and resolving power offered by the analytical capillary column (e. g. fused silica open tubular, FSOT) is sufficient for quantitative and analysis of amino acids in urine. Reproducibility data from the complete procedure are determined, coefficients of variation (CV) for most amino acids being better than 5% with a mean recovery of 96%.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...