ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 8 (1987), S. 173-181 
    ISSN: 0197-8462
    Keywords: DC electric fields ; 5-hydroxyindoleacetic acid ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Exposure to electrically charged gas molecules (air ions) has been reported to influence physiological and behavioral functions in animals and humans although there is controversy as to whether these findings are valid. A popular hypothesis concerning the reported effects of air ions is that alterations in serotonin (5HT) metabolism, particularly in the brain, are involved. We measured the concentration and turnover of 5HT in rats exposed to 5.0 × 105 ions/cm3 for up to 66 hours. Contrary to previous reports of other investigators, we were unable to demonstrate any effect of exposure to air ions or associated DC electric fields on the concentration or turnover of 5HT in rats under carefully controlled and characterized exposure conditions.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2013-08-31
    Description: The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). A Description of the Sensor, Ground Data Processing Facility, Laboratory Calibration, and First Results; Airborne Visible(Inf
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-06-28
    Description: Results are presented for the first two tasks to develop resistive strain gage systems for use up to 1250 K on blades and vanes in gas turbine engines under tests. The objective of these two tasks was to further improve and evaluate two static strain gage alloys identified as candidates in a previous program. Improved compositions were not found for either alloy. Further efforts on the Fe-11.9Al-10.6Cr weigth percent alloy were discontinued because of time dependent drift problems at 1250 K in air. When produced as a 6.5 micrometer thick sputtered film, the Pd-13Cr weight percent alloys is not sufficiently stable for this use in air at 1250 K and a protective overcoat system will need to be developed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-CR-180811 , NAS 1.26:180811 , R87-916527-1
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-06-28
    Description: The objective is to develop a new thin film resistance strain gage system which will be suitable for use inside gas turbine engines on blades or vanes at temperatures up to 1250 K. These gages are to be capable of making strain measurements to plus or minus 2000 microstrain with total errors of no more than plus or minus 10 percent during a 50 hour period. In addition to survival and stability in this hostile environment, attaining a low temperature coefficient of resistance, of the order of 20 ppm/K or less, is an important goal. This requirement arises from the presently unavoidable uncertainties in the measurement of exact temperatures inside gas turbine engines for use in making corrections for apparent strain.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA, Lewis Research Center, Turbine Engine Hot Section Technology, 1987; p 43-51
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...