ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (96)
  • Cell & Developmental Biology
  • 1995-1999
  • 1980-1984  (148)
  • 1930-1934
  • 1984  (148)
Collection
Publisher
Years
  • 1995-1999
  • 1980-1984  (148)
  • 1930-1934
Year
  • 1
    ISSN: 0148-7280
    Keywords: spermatozoa ; flow cytometry ; DNA staining ; nuclear morphology ; ultrastructure ; mammals ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: The morphological and ultrastructural changes that occur during preparation of porcine, bovine, and murine spermatozoa for flow cytometric quantification of the relative DNA content of the X- and Y-chromosome-bearing sperm populations were examined. Ejaculated spermatozoa from the boar and bull were washed using a series of dimethyl sulfoxide (DMSO) solutions prior to fixation, whereas the epididymal mouse spermatozoa were washed only in phosphate-buffered saline (PBS). Spermatozoa from all three species were then fixed in ethanol and processed for fluorochrome staining by a treatment regimen consisting of sulfhydryl reduction and proteolysis. The processed sperm nuclei were stained for DNA with the fluorochrome, 4′-6-diamidino-2-phenylindole (DAPI) before quantification by flow cytometry. Scanning and transmission electron micrographs of sperm heads taken at various steps of the preparation and staining procedures show 1) that the rigorous washing procedure disrupted the plasma and outer acrosomal membranes, 2) that ethanol fixation resulted in removal of the outer membranes and disintegration of the nuclear envelope, and 3) that thiol and proteolysis treatment removed the remaining cellular organelles including the tail and rapidly induced partial decondensation of the tightly packed chromatin. Sequential micrographs showed that the nuclear matrix of all three species increased in thickness about twofold during the preparation and staining. Consequently, the harsh procedures currently used for quantitative staining of DNA for high-resolution flow cytometric analyses destroy most cellular organelles and thereby prevent simultaneous characterization of DNA content and other sperm cell constituents.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effects of protonation and hydrogen bonding in linear Schiff bases obtained from n-butylamine with butyraldehyde, crotonaldehyde, sorbaldehyde and all-trans-retinal were studied by means of 15N and 13C NMR. The protonation-induced chemical shifts (Δδ) are an order of magnitude larger for 15N than for 13C. For 15N, this effect was found to increase with the extent of conjugation, culminating in the retinylideneimine (Δδ = -146 ppm), which constitutes a model for the study of the structure of the Schiff base linkage in visual pigments and related systems. Theoretical calculations of protonation-induced Δδ values based on MINDO/ 3 are in agreement with experimental results.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 180 (1984), S. 29-35 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: This study describes intercellular bridges in the ovaries of neonatal gerbils. Electron microscopy has revealed the presence of true intercellular bridges, connecting oogonia or oocytes, in ovaries of newborn gerbils. The cytoplasm of the intercellular channels is similar to that of the connected cells, with mitochondria, smooth and rough endoplasmic reticulum, and free ribosomes present. Lysosomes are also occasionally present in the intercellular bridges and they may be involved in early waves of oocyte atresia. An electrondense substance, 350-500 Å thick, is located immediately beneath the unit membrane of the intercellular bridges. Accumulation of electron-dense material increases the thickness of the walls of the intercellular bridges, supporting and maintaining the patency of the channels. It is suggested that the intercellular channels probably allow the interchange of nutrients, organelles, and possibly regulatory materials as well.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 180 (1984), S. 243-252 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: A small short muscle frequently acts across a joint in parallel with a vastly larger and longer muscle; therefore it should play a minimal role in the mechanical control of that joint. This study provides evidence suggesting that the small member of such a “parallel muscle combination” (PMC) may serve an important sensory feedback role. The spindle densities of large and small members of PMCs in man and the dog were determined and compared. Epaxial PMCs controlling canine intervertebral joints were dissected and tissue samples were embedded in paraffin, sectioned transversely to the muscles' long axis and, stained with hematoxylin-periodic acid-Schiff (PAS). Representative tissue sections were projected on to stereological grids and the percentage volume of spindles was determined. Data existing in the literature were used to ascertain spindle densities in human PMCs controlling joints in the cervico-occipital region and the extremities. The spindle density for each muscle in a group of PMCs controlling a particular motion was listed, and the mean spindle densities were determined for both the large and the small members of the group. Student's unpaired t test was used to determine the significance of the differences between mean spindle densities. Linear regression was calculated and the data were plotted graphically.In all PMCs examined, the spindle density of the small muscles was significantly higher than that of their large counterparts. It is therefore proposed that the small muscles of PMCs may function as “kinesiological monitors” generating important proprioceptive feedback to the central nervous system.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 196-202 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; LC/MS ; Mass spectrometry ; Field desorption ; Chemical ionization ; Gossypol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Conditions are reported for the reverse-phase HPLC analysis of gossypol and of some of its derivatives, including anhydrogossypol, gossypolone, gossypol hexaacetate, and Schiff's base derivatives. It is shown that field desorption (FD) and chemical ionization (CI) mass spectrometry have advantages over electron impact (EI) mass spectrometry for the characterization of these compounds and that combined high-performance liquid chromatography/mass spectrometry (LC/MS), especially when used in the CI mode, is particularly effective.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 13 (1984), S. 69-77 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A study of the low-energy region (below 1. 5 keV) of energy dispersive x-ray spectra has been carried out. Firstly, because some counting systems do not provide a reliable dead time correction, a new method of dealing with the problem is given. Next, the effects of different positioning of the energy discriminator within the analyser circuitry are discussed with reference to the consequences for light element analysis. Electronic noise counts can present a problem for analysis of x-rays of less than 300 eV and a straightforward method for noise removal is described. Finally, an unexpected artifact in the spectrum below 500 eV is identified; its size is related to the total number of counts in the spectrum and a practical method of dealing with it is demonstrated. Once the above factors have been taken into account a low energy spectrum is produced, consisting solely of characteristic x-ray lines and a true continuum background.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The analysis of antimalarials by high-performance liquid chromatography (HPLC)/mass spectrometry demonstrates a new dimension in specificity along with increased sensitivity compared to conventional HPLC detection methods. Both direct liquid introduction and thermospray HPLC/mass spectrometry interfaces provided molecular weight information as well as characteristic fragment ions for antimalarials not normally amenable to direct probe or gas chromatographic/mass spectrometric techniques. The direct liquid introduction interface, which incorporated a 1/100 split, showed a detection limit of 30 ng using selected ion monitoring. The thermospray technique showed less than 1 ng detection limits using selected ion monitoring.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Negative ionization resulted in the simplification of a previously published method. The new method permits the determination of 0.25 nmol l-1 nitroglycerol in plasma with a coefficient of variation of 9.1%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 22 (1984), S. 167-170 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glutacononitrile (1,3-dicyanopropene) (2) was converted to its anion (1) by treatment with sodium hydride in tetrahydrofuran. Both 13C and 1 NMR showed that the sodium salt of 1 in THF existed in three slowly interconverting geometries (U, W and S). These geometries were present in similar amounts but the relative amounts of each proved to be concentration dependent. Irradiation of a 0.01 M solution of 1 at -80°C led to the conversion of a mixture of the U, W and S forms of 1 to only the W and S forms. Upon warming to 0°C equilibrium was re-established with a half-life of approximately 8 h.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Electron Microscopy Technique 1 (1984), S. 299-309 
    ISSN: 0741-0581
    Keywords: Electron microscopy ; Ion microscopy ; Correlative microscopy ; Electron probe microanalysis ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Natural Sciences in General
    Notes: In order to correctly interpret the chemical images obtained using ion microscopy (IM), it is useful to correlate them with the information provided by conventional light microscopy (LM), secondary electron imaging (SEI), backscattered electron imaging (BEI), and electron probe microanalysis (EPMA). Accordingly, we have devised a technique of specimen preparation which allows for the application of several different microanalytical techniques to a single histologic section mounted on the same substrate. Sections are cut onto polyester plastic coverslips (devoid of peaks for any element with atomic number 〉 9 using EPMA) and studied by LM. After a light rotary coating with carbon (to prevent charging), the section can then be examined by SEI, BEI, and EPMA. Specific areas can be marked for IM study either with an objective-mounted pin tissue microlocater, or by placing small pieces of metal foil, cut in specific geometric shapes, over features of interest. After sputter-coating the sample with platinum, metal-free shadows are visible using a low-power reflected light microscope available on a typical IM sample chamber as a guide for ion beam placement. The conductive coatings also minimize specimen charging during IM. Post-IM light microscopy, SEI, and BEI are used to confirm the location of specific areas probed in the IM experiments and to provide information on differential ion-sputtering artifacts and tissue contaminants. This new correlative technique should permit better understanding of the images obtained with these diverse instruments.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...