ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (1,617)
  • Chemical Engineering  (206)
  • 1980-1984  (1,475)
  • 1960-1964  (142)
  • 1983  (521)
  • 1982  (470)
  • 1981  (484)
  • 1960  (142)
Collection
Years
  • 1980-1984  (1,475)
  • 1960-1964  (142)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 23 (1981), S. 863-877 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Results of pilot plant studies using a glass airlift fermentation device (55 liter fermentation volume) have proven the relative merits of such a system in the fermentation of a filamentous mold, Monascus purpureus, on 4% (w/w) starch media. The resultant overall yield of cell mass (Yx/s) of 0.38 was an appreciable increase over the 0.32 obtained with a pilot scale stirred tank fermentor previously studied. Power requirements of the airlift fermentor were approximately 50% of those for the mechanically agitated system. The lack of mechanical shear in the airlift system provides a more gentle environment or the cultivation of organisms than does the high degree of shear prevalent in the mechanically agitated vessels. Mass transfer of oxygen to the aqueous phase of the fermentation volume is improved significantly through use of the airlift device. Mass transfer coefficients in the range of 200 reciprocal hr were obtained to approximately 80 reciprocal hr in the stirred tank fermentor.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 509-519 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The deterioration of polyolefin, poly(ethylene terephthalate), and polyamide films under soil burial conditions extending up to 32 months has been investigated. Based on changes in their elongation at break, the films can be ranked in order of increasing sensitivity to degradation: Polyester ≃ polypropylene 〈 low-density polyethylene ≃ high-density polyethylene 〈 nylon 6.6. The degraded nylon 6.6 and polyethylene films were characterized by infrared and luminescence spectroscopy and scanning electron microscopy, as well as by wet analysis for hydroperoxides. From a comparison with the well-known oxidative sensitivity of nylon 6.6 in oxygenated water at slightly elevated temperatures, the rapid deterioration of nylon 6.6 film during soil burial was also concluded to be an oxidative process. The somewhat smaller, but significant, embrittlement of the polyethylenes studied could not be simply explained by thermal oxidation (with only trace oxidation products detectable) or microbiological attack (deterioration being unaffected by surface activation to enhance wettability).
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 59-70 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Porous high-density polyethylene specimens were implanted in the femurs of mongrel canines. At the end of the residency period (3 or 6 months), the animals were sacrificed and the implants were retrieved. The work-of-fracture of the implant specimens was then determined using the technique of Tattersall and Tappin. The work required to fracture a specimen in three-point bending by controlled crack propagation through a triangular cross section was obtained directly from the load-deflection curve. The area of the resulting fracture surface was measured by macro-photographic techniques, and the work-of-fracture was calculated as work per unit area. The implants were subsequently sectioned and examined microradiographically to determine the extent of bone ingrowth. Bone specimens adjacent to the implants and porous high-density polyethylene controls (no ingrowth) were also tested to determine their work-of-fracture. The results showed that bone adjacent to the implant specimens had a higher work-of-fracture than normal medial, canine femoral bone and was not appreciably different from the composite. The work-of-fracture of porous high-density polyethylene was not significantly increased by an increase in bone infiltration, and this anomalous behavior was attributed to a degradation of the polyethylene during implant residence. Control studies supported this hypothesis.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Fire and Materials 7 (1983), S. 79-88 
    ISSN: 0308-0501
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Architecture, Civil Engineering, Surveying , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: There are two major fire processes, an understanding of which is essential for effective fire safety design: (1) the conditions under which a combustible material may become involved in flaming combustion, and (2) the rate at which such a material, once involved, will provide an output of heat, smoke, toxic gases, etc., which can endanger people and property. The first process may be regarded as covering both ignition and spread of fire on materials; its complement is the way in which fire may become extinguished. It is necessary for such processes to bring in a characteristic of the basic combustion reaction which, directly or indirectly, expresses the reactivity of the combustion process. Thus pilot ignition is usually associated with an approximate surface fuel temperature. More basically, it is associated with a critical flow rate of volatiles and a critical heat loss from the flame, the latter being influenced by ambient oxygen and temperatures conditions as well as heat lost and gained by the fuel itself. The most important factor governing the production of dangerous product is the rate at which volatiles first (fuel controlled fires) and later air (air controlled fires) are fed into the flames. The reactivity is of less importance, although it may be one of the factors which control combustion efficiency. In general, the more efficient is the combustion the more heat is produced, but the less smoke and toxic gases are produced. Some of the main advances in the above areas are reviewed in this paper.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 16 (1981), S. 123-125 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two NQR lines were observed for 35Cl in 2,5-dichloro-4-nitroaniline at room temperature, using a self-quenched super-regenerative spectrometer. Analysis of the Zeeman effect on the two lines using a cylindrical single crystal reveals that the crystal belongs to the monoclinic system. The principal field gradient Z axes enclose an angle of 35° and 28° in the cases of the low and high frequency resonance lines, respectively. The b axis is parallel to 81°, 280°. The unit cell contains either two or a multiple of two molecules. The molecules in the crystal can be arranged into two sets, with the molecular planes in each set being parallel among each other. The angle subtended between the two planes is 159° and each of the planes is inclined to the b axis at an angle of 79.5°. There is an in-plane bending of the two C—Cl bonds by 5.5°. The ionic, single bond and double bond characters of the C—Cl bonds for both chlorines are almost equal, and are in the ratio 24:73:3.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 14 (1983), S. 144-149 
    ISSN: 0377-0486
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Raman spectra of thallous carbonate have been studied to c. 52 kbar and mid-IR spectra to 36 kbar. Details of the assignment have also been established using single-crystal IR reflectance and Raman spectroscopy. Phase transitions were found near 13 and 38 kbar on the basis of the Raman evidence, thus supporting the earlier conclusions of Meisalo and Kalliomaki based on x-ray powder and optical results. Analysis of possible space group relations between phases III (ambient) and IV showed that IV must be orthorhombic and adopt one of the D2hn groups, where n = 17, 19, 21, 25 or 28. Structural relationships between the phases are discussed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 21 (1982), S. 2265-2277 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Human fibrinogen was treated with thrombin in the presence of fibrinoligase (Factor XIIIa) and calcium ion at pH 8.5, ionic strength 0.45, and the ensuing polymerization was interrupted at various time intervals (t) both before and after the clotting time (tc) by solubilization with a solution of sodium dodecylsulfate and urea. Aliquots of the solubilized protein were subjected to gel electrophoresis on polyacrylamide gels after disulfide reduction by dithiothreitol and on agarose gels without reduction. The degree of γ-γ ligation was determined from the former and the size distribution of ligated oligomers, for degree of polymerization x from 1 to 10, from the latter. In some experiments, thrombin was inhibited, after partial polymerization, by p-nitrophenyl-p′-guanidinobenzoate. From these, it was concluded that for thrombin concentration ≤0.013 units/mL and fibrinoligase ≥30 mg/L, oligomer assembly is rapid compared with peptide A release and ligation is rapid compared with assembly. Under these conditions, the theory of the first paper of this series describes rather well the time dependences of the degree of γ-γ ligation, the weight fractions of monomer and small oligomers, and the number- and weight-average degrees of polymerization after solubilization of the staggered overlapped assemblies, each of which splits to give two strands of end-to-end ligated oligomers. The theory assumes that the second A peptide is released by thrombin more rapidly than the first by a factor q, which, from the experimental data, is determined to be 16. The subsequent assembly into staggered overlapped oligomers follows the statistics of linear polycondesation taking into account the presence of both difunctional and monofunctional combining units. For higher thrombin or lower fibrinoligase concentrations, ligation fails to keep pace with oligomer assembly, and the size distributions after solubilization show a higher proportion of very small and a lower proportion of larger ligated oligomers, owing to separation of the staggered overlapped assemblies into smaller fragments.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 22 (1983), S. 1489-1498 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Empirical force-field calculations and ir and 1H-nmr spectra indicate that five-membered (C5) and seven-membered (C7eq) hydrogen-bonded rings are the preferred conformations of acetyl-L-Phe p-acetyl and p-valeryl anilides in nonpolar media. The C5/C7eq ratio was found to be dependent on the dryness of the solute and the solvent. This fact and the results from conformational-energy calculations suggest that a molecule of water participates in the stabilization of the C7eq conformation.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Biocompatible, biodegradable copolymers of glutamic acid and ethyl glutamate were evaluated for their permeability to proteins ranging in molecular weight from 12,300 to 69,000. The results showed that the copolymers were sufficiently permeable that they could be used for the preparation of implantable, controlled-release systems capable of releasing therapeutic amounts of high-molecular-weight drugs.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...